Have a personal or library account? Click to login
Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns Cover

Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns

Open Access
|May 2012

Abstract

The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.

Language: English
Page range: 90 - 97
Published on: May 28, 2012
Published by: Slovak Academy of Sciences, Institute of Measurement Science
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2012 B. Trifkovic, I. Budak, A. Todorovic, J. Hodolic, T. Puskar, D. Jevremovic, D. Vukelic, published by Slovak Academy of Sciences, Institute of Measurement Science
This work is licensed under the Creative Commons License.

Volume 12 (2012): Issue 3 (June 2012)