Have a personal or library account? Click to login
Non-invasive Studies on Age Related Parameters Using a Blood Volume Pulse Sensor Cover

Non-invasive Studies on Age Related Parameters Using a Blood Volume Pulse Sensor

Open Access
|Aug 2008

References

  1. Hashimoto, J., Chonan, K., Aoki, Y., Nishimura, T., Ohkubo, T., Hozawa, A., Suzuki, M., Matsubara, M., Michimata, M., Araki, T., Imai, Y. (2002). Pulse wave velocity and the second derivative of the finger photoplethysmogram in treated hypertensive patients: their relationship and associating factors. J. Hypertens.20, 2415-2422.10.1097/00004872-200212000-0002112473866
  2. Jayasree, V. K., Shaija, P. J., Manu, P. J., Radhakrishnan, P. (2008). An optoelectronic sensor configuration for the determination of age related indices using blood volume pulse. Sensors & Transducers Journal87(1), 39-45.
  3. Brumfield, A. M., Andrews, M. E. (2005). Digital pulse contour analysis.investigating age-dependent indices of arterial compliance. Physiol. Meas.26, 599-608.
  4. Nitzan, M. Khanokh, B., Slovik, Y. (2002). The difference in pulse transit time to the toe and finger measured by photoplethysmography. Physiol. Meas.23, 85-93.10.1088/0967-3334/23/1/30811876244
  5. Sherebrin, M. H, Sherebrin, R. Z. (1990). Frequency analysis of the peripheral pulse-wave detected in the finger with photoplethysmography. IEEE Trans. Biomed. Eng.37, 313-317.10.1109/10.523322329004
  6. Oliva, I., Isper, J., Roztocil, K., Guttenbergerova, K. (1976). Fourier analysis of the pulse wave in obliterating arteriosclerosis. VASA, 5, 95-100.
  7. Hashimoto, J., Watabe, D., Kimura, A., Takahashi, H., Ohkubo, T., Totsune, K., Imai, Y. (2005). Determinants of the second derivative of the finger photoplethysmogram and Brachial- Ankle pulse wave velocity: The Ohasama study. Am. J. Hypertens.18, 477-485.10.1016/j.amjhyper.2004.11.00915831356
  8. Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., Ibukiyama, C. (1998). Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform. Hypertension32, 365-370.10.1161/01.HYP.32.2.3659719069
  9. Jago, J. R., A. Murray (1988). Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography. Clin. Phys. Physiol. Meas.9, 319-329.10.1088/0143-0815/9/4/0033233886
  10. Murray, W. B., P. A. Foster (1996) The peripheral pulse wave: information overlooked. J. Clin. Monit.12, 365-377.10.1007/BF020776348934343
  11. Allen, J., Murray, A. (2003). Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sites. Physiol. Meas.24, 297-307.10.1088/0967-3334/24/2/30612812416
  12. Allen, J., Murray, A. (2002). Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes. J. Hum. Hypertens.16, 711-717.10.1038/sj.jhh.100147812420195
  13. Allen, J. (2007). Photoplethysmography and its application in clinical physiological measurement. Physiol. Meas.28, R1-R39.10.1088/0967-3334/28/3/R0117322588
  14. Hlimonenko, I., Meigas, K., Vahisalu, R. (2003). Waveform analysis of peripheral pulse wave detected in the finger tip with photoplethysmograph. Meas. Sci. Rev.3, 49-52.
  15. Millasseau, S. C., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J. R., Ritter, J. M., Chowienczyk, P. J. (2000). Noninvasive assesssment of the digital volume pulse: comparison with the peripheral pressure pulse. Hypertension, 36, 952-956.10.1161/01.HYP.36.6.95211116106
  16. Millasseau, S. C., Kelly, R. P., Ritter, J. M., Chowienczyk, P. J. (2002). Determination of age related increases in large artery stiffness by digital pulse contour analysis. Clin. Sci.103, 371-377.10.1042/cs103037112241535
  17. Shaija, P. J., Jayasree, V. K., Radhakrishnan, P. (2007). Blood volume pulse sensor using peripheral pulse detected in the finger tips with photoplethysmograph and assessment of bilateral symmetry. In SENNET'07: Proceedings of International Conference on Sensors and Related Networks, December 12-14 2007. Vellore, India: VIT University.
  18. Lopez-Beltran, E. A., Blackshear, P. L., Finkelstein, S. M., Cohn, J. N. (1998). Non- invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method. Med. Biol. Eng. Comput.36, 748-753.10.1007/BF0251887910367467
  19. Wilkinson, I. B., MacCallum, H., Rooijmans, D. F., Murray, G. D., Cockcroft, J. R., et. al. (2000). Increased augmentation index and systolic stress in type I diabetes mellitus. QJM - Int. J. Med.93 (7), 441-448.10.1093/qjmed/93.7.44110874053
Language: English
Page range: 82 - 86
Published on: Aug 27, 2008
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2008 V. Jayasree, T. Sandhya, P Radhakrishnan, published by Slovak Academy of Sciences, Institute of Measurement Science
This work is licensed under the Creative Commons License.

Volume 8 (2008): Issue 4 (August 2008)