Figure 1:
Leakage occurred at the joints between panels (Yang et al., 2024)
Table 1:
details of specimens
| specimen | Wall thickness | Number of cold joints | aspect ratio |
|---|---|---|---|
| [mm] | |||
| T40-0 | 40 | 0 | |
| T60-0 | 60 | 0 | |
| T80-0 | 80 | 0 | |
| T100-0 | 100 | 0 | |
| T60-1 | 60 | 1 | |
| T60-2 | 60 | 2 | |
| T100-2 | 100 | 2 |

Figure 2:
Specimens details (unite in m)

Figure 3:
Polypropylene Fiber
Table 2:
Mix proportions of Self-Compact Polypropylene Fiber-Reinforced Concrete (SCPPFRC)
| Cement [kg/m3] | Fly Ash [kg/m3] | Sand [kg/m3] | Gravel [kg/m3] | Water [kg/m3] | Admixture S.P. [kg/m3] | Polypropylene Fiber P.P.F. [kg/m3] |
|---|---|---|---|---|---|---|
| 350 | 60a | 800 | 725 | 165b | 7c | 4.55d |
| a Fly Ash=17% of cement weight, b w/b =40%, c S.P./b=1.7% and d Polypropylene Fiber =0.5% of total volume | ||||||
| Mix strength grade, MPa at 28 days | 38.71 | |||||

Figure 4:
V-funnel, slump flow and L-box tests of fresh concrete
Table 3:
Fresh properties result of SCC mix
| Mix | Properties related to self-compact ability | |||
|---|---|---|---|---|
| Slump flow [mm] | T50cm flow time [Sec] | V-funnel time [Sec] | L-box (H2/H1) | |
| SCCa | 680 | 4 | 8 | 0.98 |
| SCPFRCb | 615 | 6 | 21 | 0.76 |
| Typical range of values (EFNARC, 2005) | 650-800 | 2–5 | 6–12 | 0.8–1.0 |

Figure 5:
Shows the testing process of the concrete material parameters.
Table 4:
Mechanical properties of concrete
| Compressive Strength [MPa] | Splitting tensile strength [MPa] | Flexural strength [MPa] | Elastic Modulus [GPa] |
|---|---|---|---|
| 38.71 | 4.86 | 4.62 | 33 |
Table 5:
Mechanical properties of steel reinforcements
| Nominal diameter [mm] | Actual Diameter [mm] | Yield Stress [MPa] | Ultimate Stress [MPa] | Elastic Modulus [GPa] |
|---|---|---|---|---|
| 6 | 5.9 | 430 | 560 | 200 |

Figure 6:
Schematic diagram of the specimen monitoring system (unit: m)

Figure 7:
Experimental Loading Setup System

Figure 8:
Load-midspan deflection curves of specimens with different thicknesses
Table 6:
Characteristic loads, midspan deflections of specimens with different thickness
| specimen | Stiffness Ratio | Pyield | δyield | Pultimate | δultimate | Pcr |
|---|---|---|---|---|---|---|
| EI/γw*h4 | [kN] | [mm] | [kN] | [mm] | [kN] | |
| T40-0 | 434 | 1.70 | 5. 60 | 2 | 49.25 | 1.72 |
| T60-0 | 1465(↑238%)* | 3.80(↑124%)* | 5.40 (↓4%)* | 6.07(↑204%)* | 43.55(↓12%)* | 3.86(↑124%)* |
| T80-0 | 3472(↑700%)* | 5.40(↑218%)* | 2.80 (↓50%)* | 7.8(↑290%)* | 22.80(↓54%)* | 5.50(↑220%)* |
| T100-0 | 6782(↑1463%)* | 8.20(↑382%)* | 2.38(↓58%)* | 9.40(↑370%)* | 13.85(↓72%)* | 8.28(↑381%)* |

Figure 9:
Relations of Load and Midspan deflection with different thicknesses of specimens

Figure 10:
Load- midspan deflection curves of specimens with cold joints
Table 7:
Characteristic loads, midspan deflections of specimens with cold joints

Figure 11:
Effect Number of cold joints on load of specimens

Figure 12:
Effect Number of cold joints on midspan deflection of specimens

Figure 13:
Effect Number of cold joints on variation of load and midspan deflection of specimens

Figure 14:
Failure Mode

Figure 15:
Relationship between length of the segments (L) to its thickness (T) and depth of excavation (H) relative to thickness (T)

Figure 16:
Relationship of segment length-to-thickness ratio and the maximum lateral displacement δhmax of the diaphragm wall

Figure 17:
Relationship of Maximum Wall Deflection and Wall’s System Stiffness (Mana & Clough, 1981)
Table 8:
Ductility index of tested specimens
| specimen | δyield | δultimate | Ductility |
|---|---|---|---|
| [mm] | [mm] | ||
| T40-0 | 5. 60 | 49.25 | 8.80 |
| T60-0 | 5.40 | 43.55 | 8.10 |
| T80-0 | 2.80 | 22.80 | 8.00 |
| T100-0 | 2.38 | 13.85 | 5.82 |
| T60-1 | 5.00 | 48.00 | 9.00 |
| T60-2 | 4.90 | 52.92 | 10.80 |
| T100-2 | 3.00 | 16.62 | 5.50 |

Figure 18:
Ductility of specimens with different thicknesses

Figure 19:
Ductility of specimens with number of cold joints

Figure 20:
Definition of yielding load (Feng et al., 2017)

Figure 21:
Relation the load with distance from the line
Table 9:
Definition of yielding load by Farthest Point Method
| specimen | Wall thickness | Number of cold joints | dmax | Pyield | δyield | Pyield by Tangent Intersection Method |
|---|---|---|---|---|---|---|
| [mm] | ------ | [mm] | [kN] | [mm] | [kN] | |
| T40-0 | 40 | 0 | 1.48 | 1.70 | 5.25 | 1.70 |
| T60-0 | 60 | 0 | 3.03 | 3.78 | 5.22 | 3.80 |
| T80-0 | 80 | 0 | 4.23 | 5.41 | 2.75 | 5.40 |
| T100-0 | 100 | 0 | 5.44 | 8.03 | 2.30 | 8.20 |
| T60-1 | 60 | 1 | 2.65 | 3.22 | 4.75 | 3.10 |
| T60-2 | 60 | 2 | 2.22 | 2.72 | 5.04 | 2.65 |
| T100-2 | 100 | 2 | 5.27 | 7.38 | 2.88 | 7.40 |