Have a personal or library account? Click to login
Phased Array Receiving Coils for Low Field Lungs MRI: Design and Optimization Cover

Phased Array Receiving Coils for Low Field Lungs MRI: Design and Optimization

Open Access
|Jun 2011

References

  1. Ohliger, M. A., Sodickson, D. K. (2006). An introduction to coil array design for parallel MRI. NMR in Biomedicine, 19 (3), 300-315.10.1002/nbm.1046
  2. Pruessmann, K. P., Weiger, M., Scheidegger, M. B. et al. (1999). SENSE: Sensitivity encoding for fast MRI. Magnetic Resonance in Medicine, 42 (5), 952-962.10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S
  3. Andris, P., Frollo, I. (2002). Optimisation of NMR coils by genetic algorithms. Measurement Science Review, 2 (2), 13-22.
  4. Sodickson, D. K., Manning, W. J. (1997). Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays. Magnetic Resonance in Medicine, 38 (4), 591-603.10.1002/mrm.1910380414
  5. Griswold, M. A., Jakob, P. M., Heidemann, R. M. et al. (2002). Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magnetic Resonance in Medicine, 47 (6), 1202-1210.10.1002/mrm.10171
  6. Breuer, F. A., Kannengiesser, S. A. R., Blaimer, M. et al. (2009). General formulation for quantitative G-factor calculation in GRAPPA reconstructions. Magnetic Resonance in Medicine, 62 (3), 739-746.10.1002/mrm.22066
  7. Griswold, M. A., Jakob, P. M., Nittka, M. et al. (2000). Partially parallel imaging with localized sensitivities (PILS). Magnetic Resonance in Medicine, 44 (4), 602-9.10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO;2-5
  8. Roemer, P. B., Edelstein, W. A., Hayes, C. E. et al. (1990). The NMR phased-array. Magnetic Resonance in Medicine, 16 (2), 192-225.10.1002/mrm.1910160203
  9. Blaimer, M., Breuer, F., Mueller, M. et al. (2004). SMASH, SENSE, PILS, GRAPPA: how to choose the optimal method. Topics in Magnetic Resonance Imaging, 15 (4), 223-36.10.1097/01.rmr.0000136558.09801.dd
  10. Seiberlich, N., Ehses, P., Duerk, J. et al. (2011). Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging. Magnetic Resonance in Medicine, 65 (2), 492-505.10.1002/mrm.22618
  11. Li, B. K., Hui, H. T., Yang, C. H. et al. (2008). A new decoupling method for phased arrays in magnetic resonance imaging: an experimental approach. IET Science Measurement & Technology, 2 (5), 317-325.10.1049/iet-smt:20080033
  12. Guclu, C. C., Boskamp, E., Zheng, T. et al. (2004). A method for preamplifier-decoupling improvement in quadrature phased-array coils. Journal of Magnetic Resonance Imaging, 19 (2), 255-8.10.1002/jmri.1044914745761
  13. Jevtic, J. (2001). Ladder networks for capacitive decoupling in phased-array coils. In Proceedings of the 9th International Society for Magnetic Resonance in Medicine, 17.
  14. Frollo, I., Andris, P., Přibil, J. et al. (2009). Magnetic field measurement of a planar coil using magnetic rezonance imaging method. Measurement Science Review, 10 (3), 97-101.
Language: English
Page range: 61 - 66
Published on: Jun 3, 2011
Published by: Slovak Academy of Sciences, Institute of Measurement Science
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2011 L. Vojtíšek, I. Frollo, L. Valkovič, D. Gogola, V. Juráš, published by Slovak Academy of Sciences, Institute of Measurement Science
This work is licensed under the Creative Commons License.

Volume 11 (2011): Issue 2 (April 2011)