Have a personal or library account? Click to login
A Simple Procedure to Determine Complex Permittivity of Moist Materials Using Standard Commercial Coaxial Sensor Cover

A Simple Procedure to Determine Complex Permittivity of Moist Materials Using Standard Commercial Coaxial Sensor

By: M. Jusoh,  Z. Abbas,  J. Hassan,  B. Azmi and  A. Ahmad  
Open Access
|Apr 2011

Abstract

A simple procedure was developed to determine complex permittivity of moist materials for known percentage of moisture content at any frequency based using a standard commercial coaxial sensor. Polynomial fitting and Gaussian elimination method were applied to obtain a single equation of complex permittivity as a function of frequency and moisture content. The empirical equation was tested for new samples and was found to have mean error percentage of 5.14 % and 10.22 % for dielectric constant and loss factor, respectively, when compared to a commercial probe.

Language: English
Page range: 19 - 22
Published on: Apr 8, 2011
Published by: Slovak Academy of Sciences, Institute of Measurement Science
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2011 M. Jusoh, Z. Abbas, J. Hassan, B. Azmi, A. Ahmad, published by Slovak Academy of Sciences, Institute of Measurement Science
This work is licensed under the Creative Commons License.

Volume 11 (2011): Issue 1 (February 2011)