Have a personal or library account? Click to login
Testing Viscosity of MR Fluid in Magnetic Field Cover

Testing Viscosity of MR Fluid in Magnetic Field

Open Access
|Jun 2008

Abstract

The purpose of this paper was to determine the coefficient of viscosity of a magneto-rheological fluid for different values of the magnetic field and to determine parameters at which the flow of the fluid through a capillary is stopped. To determine the coefficient of viscosity, a method of indirect measurement was implemented using a reference fluid with the known properties. A test stand with a capillary viscometer was constructed. The measurements showed that the viscosity of the magneto-rheological fluid was linearly dependent in a wide range of values of the magnetic induction.

Language: English
Page range: 58 - 60
Published on: Jun 25, 2008
Published by: Slovak Academy of Sciences, Institute of Measurement Science
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2008 A. Roszkowski, M. Bogdan, W. Skoczynski, B. Marek, published by Slovak Academy of Sciences, Institute of Measurement Science