Have a personal or library account? Click to login
Numerical Comparison of Thermal Behaviour Between Ventilated Facades Cover

Numerical Comparison of Thermal Behaviour Between Ventilated Facades

Open Access
|May 2020

Abstract

Increasingly high demands on environmental protection are intensifying the development of sustainable construction. Ventilated facades can provide an energy-efficient alternative to standard facades, that is, external thermal insulation composite systems (ETICS). The article compares standard facades, which was a reference, to ventilated facades in two variants: closed joints and open joints. The comparison was made by means of numerical simulations of computational fluid dynamic (CFD), under conditions of high outside temperature and high sunshine. The results showed great benefits of using ventilated facades in such external climate conditions. It was also observed that the selection of the variant of ventilated facade in the system of close or open joints has minimal influence on thermal efficiency of the whole partition.

DOI: https://doi.org/10.2478/sgem-2019-0044 | Journal eISSN: 2083-831X | Journal ISSN: 0137-6365
Language: English
Page range: 297 - 305
Submitted on: Feb 18, 2020
Accepted on: Mar 23, 2020
Published on: May 20, 2020
Published by: Sciendo
In partnership with: Paradigm Publishing Services
Publication frequency: 4 times per year

© 2020 Krzysztof Schabowicz, Łukasz Zawiślak, published by Sciendo