Have a personal or library account? Click to login
Effective atomic number and photon buildup factor of bismuth doped tissue for photon and particles beam interaction Cover

Effective atomic number and photon buildup factor of bismuth doped tissue for photon and particles beam interaction

Open Access
|Mar 2022

Abstract

Introduction: The doping of high Z nanoparticles into the tumor tissue increases the therapeutic efficiency of radiotherapy called nanoparticle enhanced radiotherapy (NERT). In the present study, we are identifying the effective types of radiation and effective doping concentration of bismuth radiosensitizer for NERT application by analyzing effective atomic number (Zeff) and photon buildup factor (PBF) of bismuth (Bi) doped soft tissue for the photon, electron, proton, alpha particle, and carbon ion interactions.

Material and methods: The direct method was used for the calculation of Zeff for photon and electron beams (10 keV-30 MeV). The phy-X/ZeXTRa software was utilized for the particle beams such as proton, alpha particle, and carbon ions (1-15 MeV). Bismuth doping concentrations of 5, 10, 15, 20, 25 and 30 mg/g were considered. The PBF was calculated over 15 keV-15 MeV energies using phy-X/PSD software.

Results: The low energy photon (<100 keV) interaction with a higher concentration of Bi dopped tissue gives the higher values of Zeff. The Zeff increased with the doping concentration of bismuth for all types of radiation. The Zeff was dependent on the type of radiation, the energy of radiation, and the concentration of Bi doping. The particle beams such as electron, proton, alpha particle, and carbon ion interaction gives the less values of Zeff has compared to photon beam interaction. On the other hand, the photon buildup factor values were decreased while increasing the Bi doping concentration.

Conclusions: According to Zeff and PBF, the low energy photon and higher concentration of radiosensitizer are the most effective for nanoparticle enhanced radiotherapy application. Based on the calculated values of Zeff, the particle beams such as electron, proton, alpha particle, and carbon ions were less effective for NERT application. The presented values of Zeff and PBF are useful for the radiation dosimetry in NERT.

DOI: https://doi.org/10.2478/pjmpe-2022-0005 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 37 - 51
Submitted on: May 14, 2021
Accepted on: Dec 12, 2021
Published on: Mar 29, 2022
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2022 K Srinivasan, E James Jabaseelan Samuel, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.