Have a personal or library account? Click to login
Neutron conversion coefficients of ambient dose equivalent and personal dose equivalent Cover

Neutron conversion coefficients of ambient dose equivalent and personal dose equivalent

Open Access
|Mar 2022

Abstract

Introduction: This work aims to calculate the ambient and personal dose equivalent conversion coefficients.

Material and methods: The conversion coefficients have been calculated using MC simulation. Additionally, this paper proposes a new method that depends on an analytical approach.

Results: The obtained results in good agreement between MC and an analytical approach were observed. The obtained results were compared to those published in ICRU 57 report.

Conclusions: We deduced that the analytical approach is as effective and suitable as the MC simulation to calculate the operational quantity conversion coefficients.

DOI: https://doi.org/10.2478/pjmpe-2022-0006 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 52 - 59
Submitted on: Jun 24, 2021
Accepted on: Jan 24, 2022
Published on: Mar 29, 2022
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2022 Hassan Al Kanti, Otman El Hajjaji, Tarek El Bardouni, Maged Mohammed, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.