Fig. 1.
Schematic diagram of the DIC method.

Fig. 2.
Simulated reference speckle pattern (a), low-illumination speckle pattern (b), and their gray histograms.

Fig. 3.
Comparison of simulated speckle enhancement results and gray histograms.
Table 1.
Comparison of simulation speckle evaluation indicators.
| Algorithm | MIG | Shannon entropy | PSNR | SSIM |
|---|---|---|---|---|
| EnlightenGAN | 22.54 | 6.34 | 28.02 | 0.87 |
| Zero-DCE | 20.58 | 5.88 | 22.35 | 0.83 |
| SCI | 17.52 | 5.46 | 21.25 | 0.81 |
| IcNET | 16.14 | 5.47 | 20.11 | 0.77 |

Fig. 4.
The true reference speckle pattern, the low-illumination speckle pattern, and their grayscale histograms.

Fig. 5.
Comparison of the actual speckle enhancement results.
Table 2.
Comparison of real speckle evaluation indicators.
| Algorithm | MIG | Shannon entropy | PSNR | SSIM |
|---|---|---|---|---|
| EnlightenGAN | 17.33 | 6.52 | 22.31 | 0.84 |
| Zero-DCE | 12.22 | 5.84 | 20.03 | 0.79 |
| SCI | 10.28 | 5.88 | 18.12 | 0.74 |
| IcNET | 9.34 | 5.82 | 12.83 | 0.75 |

Fig. 6.
The flowchart of the EnDIC algorithm.

Fig 7.
The results of the simulation translation experiment.

Fig. 8.
The results of the simulated rotation experiment.

Fig. 9.
Speckle image acquisition system.

Fig. 10.
The results of the real translation experiment.

Fig. 11.
The results of the actual rotation experiment.

Fig. 12.
The absolute mean error results of the calculation for low-illumination speckle images.

Fig. 13.
The absolute mean error calculated by the algorithm for a translational displacement of 0.9 pixels under different voltages.