Calculation of the Main Frequency of an NMR Signal from an Even Frequency Spectrum Cover

Calculation of the Main Frequency of an NMR Signal from an Even Frequency Spectrum

By: Peter Andris and  Ivan Frollo  
Open Access
|Dec 2024

References

  1. Brigham, E. O. (1973). The Fast Fourier Transform. Prentice-Hall, ISBN 978-0133074963.
  2. Čížek, V. (1981). Discrete Fourier Transforms and their Applications. Prague, Czech Republic: SNTL, ISBN 9780852748008. (in Czech)
  3. Andris, P., Szomolányi, P., Strolka, I., Banič, B., Bačiak, L., Weis, J., Jellúš, V., Frollo, I. (2003). Two approaches to measurement of the signal frequency in NMR based magnetic field stabiliser. Measurement Science Review, 3, 53-56. https://www.measurement.sk/2003/S3/Andris1.pdf
  4. Andris, P., Frollo, I., Přibil, J., Gogola, D., Dermek, T. (2023). Conversion of the Bruker minispec instrumentation into the static magnetic field standard. Measurement Science Review, 23 (3), 124-129. https://doi.org/10.2478/msr-2023-0016
  5. Sundramoorthy, S. V., Epel, B., Halpern, H. J. (2017). A pulse EPR 25 mT magnetometer with 10 ppm resolution. Applied Magnetic Resonance, 48 (8), 805-811. https://doi.org/10.1007/S00723-017-0902-0
  6. Keller, P. (2011). NMR magnetometers. Magnetics Technology International, 68-71. ISSN 2397-589X.
  7. Ulvr, M., Kupec, J. (2018). Improvements to the NMR method with flowing water at CMI. IEEE Transaction on Instrumentation and Measurement, 67 (1), 204-208. https://doi.org/10.1109/TIM.2017.2756119
  8. Hoult, D. I., Richards, R. E. (1976). The signal-to-noise ratio of the nuclear magnetic resonance experiment. Journal of Magnetic Resonance, 24 (1), 71-85. https://doi.org/10.1016/0022-2364(76)90233-X
  9. Hoult, D. I., Lauterbur, P. C. (1979). The sensitivity of the zeugmatographic experiment involving human samples. Journal of Magnetic Resonance, 34 (2), 425-433. https://doi.org/10.1016/0022-2364(79)90019-2
  10. Weis, J., Ericsson, A., Hemmingsson, A. (1999). Chemical shift artifact-free microscopy: Spectroscopic microimaging of the human skin. Magnetic Resonance in Medicine, 41 (5), 904-908. https://doi.org/10.1002/(SICI)1522-2594(199905)41:5%3C904::AIDMRM8%3E3.0.CO;2-4
  11. Bartušek, K., Dokoupil, Z., Gescheidtová, E. (2007). Mapping of magnetic field around small coil using the magnetic resonance method. Measurement Science and Technology, 18 (7), 2223-2230. https://doi.org/10.1088/0957-0233/18/7/056
  12. Nešpor, D., Bartušek, K., Dokoupil, Z. (2014). Comparing saddle, slotted-tube and parallel-plate coils for magnetic resonance imaging. Measurement Science Review, 14 (3), 171-176. https://doi.org/10.2478/msr-2014-0023
  13. Latta, P., Gruwel, M. L., Volotovskyy, V., Weber, M. H., Tománek, B. (2008). Single-point imaging with a variable phase encoding interval. Magnetic Resonance Imaging, 26 (1), 109-116. https://doi.org/10.1016/j.mri.2007.05.004
  14. Witkovsky, V., Frollo, I. (2020). Measurement science is the science of sciences - there is no science without measurement. Measurement Science Review, 20 (1), 1-5. https://doi.org/10.2478/msr-2020-0001
Language: English
Page range: 211 - 214
Submitted on: Jul 12, 2024
Accepted on: Oct 20, 2024
Published on: Dec 24, 2024
Published by: Slovak Academy of Sciences, Institute of Measurement Science
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2024 Peter Andris, Ivan Frollo, published by Slovak Academy of Sciences, Institute of Measurement Science
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.