Combination of Non-contact and Contact Measuring Methods for Analyzing Structural Conditions of Dry Transformers
References
- Orman, M., Pinto, C. T. (2013). Usage of acoustic camera for condition monitoring of electric motors. IEEE International Conference of IEEE Region 10 (TENCON 2013). IEEE, 1-4. https://doi.org/10.1109/TENCON.2013.6718909
- Borucki, S., Cichon, A., Subocz, J. (2012). Detection of partial discharges in transformer insulation bushings using acoustic emission method. Przeglad Elektrotechniczny, 88 (4A), 18-21. https://doi.org/10.2478/v10048-011-0030-1
- Cichon, A., Berger, P. (2014). Possibility of using acoustic acoustic emission method for testing load tap changers during normal operation of the transformer. In International Conference on High Voltage Engineering and Application (ICHVE). IEEE. https://doi.org/10.1109/ICHVE.2014.7035479
- Boczar, T., Borucki, S., Cichon, A., Zmarzly, D. (2009). Application possibilities of artificial neural networks for recognizing partial discharges measured by the acoustic emission method. IEEE Transactions on Dielectrics and Electrical Insulation, 16, 214-223. https://doi.org/10.1109/TDEI.2009.4784570
- Kunicki, M., Cichon, A. Borucki, S. (2016). Study on descriptors of acoustic emission signals generated by partial discharges under laboratory conditions and in on-site electrical power transformer. Archives of Acoustics, 41 (2), 265-276. https://doi.org/10.1515/aoa-2016-0026
- Olszewska, A. (2010). Location of partial discharge sources in oil transformer with the use of analysis of acoustic emission signals in various frequency bands. Przeglad Elektrotechniczny, 86 (11B), 63-65.
- Jin, M., Pan, J. (2016). Vibration transmission from internal structures to the tank of an oil-filled power transformer. Applied Acoustics, 113, 1-6. https://doi.org/10.1016/j.apacoust.2016.05.022
- Bartoletti, C., Desiderio, M., Di Carlo, D., Fazio, G., Muzi, F., Sacerdoti G., Salvatori, F. (2004). Vibro-acoustic techniques to diagnose power transformers. IEEE Transactions on Power Delivery, 19 (1), 221-229. https://doi.org/10.1109/TPWRD.2003.820177
- Olszewska, A., Witos, F. (2016). Identification of acoustic emission signals originating from the core magnetization of power oil transformer. Archives of Acoustics, 41 (4), 799-812. https://doi.org/10.1515/aoa-2016-0077
- Usha, K., Usa, S. (2015). Inter disc fault location in transformer windings using SFRA. IEEE Transaction on Dielectrics and Electrical Insulation, 22 (6), 3567-3573. https://doi.org/10.1109/TDEI.2015.005060
- Ramírez-Niño, J., Pascacio, A. (2009). Acoustic measuring of partial discharge in power transformers. Measurement Science and Technology, 20 (11), 1-9. https://doi.org/10.1088/0957-0233/20/11/115108
- Boczar, T., Cichon, A., Borucki, S. (2014). Diagnostic expert system of transformer insulation systems using the acoustic emission method. IEEE Transactions on Dielectrics and Electrical Insulation, 21, (2), 854-865. https://doi.org/10.1109/TDEI.2013.004126
- García, B., Burgos, J. C., Alonso, A. M. (2006). Transformer tank vibration modeling as a method of detecting winding deformations-part I: Theoretical foundation, part II: Experimental verification. IEEE Transactions on Power Delivery, 21 (1), 157-169. https://doi.org/10.1109/TPWRD.2005.852280
- Shuai, P., Biela, J. (2014). Investigation of acoustic noise sources in medium frequency, medium voltage transformers. In 16th European Conference on Power Electronics and Applications (EPE-ECCE Europe). IEEE. https://doi.org/10.1109/EPE.2014.6910949
- Su, C. C., Tang, Y. W., Tai, C. C., Chen, J. F. (2011). Detection and location of partial discharge in cast-resin dry-type transformers using a waveguide and a new acoustic emission sensor pair design. Journal of Zhejiang University - Science C: Computers & Electronics, 12 (4), 345-350. https://doi.org/10.1631/jzus.C1000126
- Kunicki, M., Wotzka, D. A. (2019). Classification method for select defects in power transformers based on the acoustic signals. Sensors, 19 (23), 5212. https://doi.org/10.3390/s19235212
- Frivaldsky, M., Piri, M., Spanik, P., Jaros, V., Kondelova, A. (2017). Peak efficiency and peak power point operation of wireless energy transfer (WET) system-analysis and verification. Electrical Engineering, 99 (4), 1439-1451. https://doi.org/10.1007/s00202-017-0658-4
- Yoon, Y., Son, Y., Cho, J., Jang, S., Kim, Y. G., Choi, S. (2021). High-frequency modeling of a three-winding power transformer using sweep frequency response analysis. Energies, 14 (13), 4009. https://doi.org/10.3390/en14134009
- Kudelcik, J., Hardon, S., Trnka, P., Michal, O., Hornak, J. (2021). Dielectric responses of polyurethane/zinc oxide blends for dry-type cast cold-curing resin transformers. Polymers, 13 (3), 375. https://doi.org/10.3390/polym13030375
- Lewandowski, K., Moranda, H. (2018). Detection of windings short-circuits in a power transformer using the SFRA method. Przeglad Elektrotechniczny, 94 (10), 118-121. https://doi.org/10.15199/48.2018.10.27
- Brandt, M. (2016). Identification failure of 3 MVA furnace transformer. In Diagnostic of Electrical Machines and Insulating Systems in Electrical Engineering (DEMISEE). IEEE. https://doi.org/10.1109/DEMISEE.2016.7530472
- Rajamani, R, Rajappa, M., Madanmohan, B. (2017). Sweep frequency response analysis based diagnosis of shorts within transformer windings. IET Generation Transmission & Distribution, 11 (17), 4274-4281. https://doi.org/10.1049/iet-gtd.2017.0123
- Nunez, A. (2006). Recent case studies in the application of acoustic emission technique in power transformers. IEEE/PES Transmission and Distribution Conference and Exposition: Latin America. IEEE. https://doi.org/10.1109/TDCLA.2006.311526
- Ma, B., Xu, J. (2017). Study of fiber-optic acoustic emission sensor for partial discharges detection in power transformer. Spectroscopy and Special Analysis, 37 (7), 2273-2277. https://doi.org/10.3964/j.issn.1000-0593(2017)07-2273-05
- Sikorski, W. (2010). The detection and identification of partial discharges in power transformer with the use of the acoustic emission method. Przeglad Elektrotechniczny, 86 (4), 229-232.
- Kuo, C. C. (2009). Artificial recognition system for defective types of transformers by acoustic emission. Expert Systems with Applications, 36 (7), 10304-10311. https://doi.org/10.1016/j.eswa.2009.01.046
- Shanker, T. B., Nagamani, H. N., Puneka, G. S. (2012). Thermal effects on acoustic emission based PD in transformer oil: A study. In 10th IEEE International Conference on the Properties and Applications of Dielectric Materials (ICPADM). IEEE. https://doi.org/10.1109/ICPADM.2012.6318903
- Shuai, P., Biela, J. (2017). Influence of material properties and geometric shape of magnetic cores on acoustic noise emission of medium-frequency transformers. IEEE Transactions on Power Electronics, 32 (10), 7916-7931. https://doi.org/10.1109/TPEL.2016.2636572
- Rathod, V. B., Kumbhar, G. B., Bhalja, B. R. (2022). Partial discharge detection and localization in power transformers based on acoustic emission: Theory, methods, and recent trends. IETE Technical Review, 39 (3), 540-552. https://doi.org/10.1080/02564602.2021.1871672
- Pokorný, V. (2013). Elimination of noise emission of electrical equipment. Doctoral dissertation, VSB-TU Ostrava, Czech Republic.
- Ziomek, W., Kuffelz, E., Sikorski, W., Staniek, P., Siodla, K. (2008). Location and recognition of partial discharge sources in a power transformer using advanced acoustic emission method. Przeglad Elektrotechniczny, 84 (10), 20-23.
- Gange, M. (2011). Low-frequency and tonal characteristics of transformer noise. In Acoustics 2011 - Breaking New Ground: Proceedings of the Annual Conference of the Australian Acoustical Society. ISBN 978-0-9757855-8-4.
- Norsonic AS. Nor848A acoustic camera.
- Witos, F., Olszewska, A., Opilski, Z., Lisowska, A, Szerszen, G. (2020). Application of acoustic emission and thermal imaging to test oil power transformers. Energies, 13 (22), 5955. https://doi.org/10.3390/en13225955
- Ma, B., Xu, J. (2017). Study of fiber-optic acoustic emission sensor for partial discharges detection in power transformer. Spectroscopy and Spectral Analysis, 37 (7), 2273-2277. https://doi.org/10.3964/j.issn.1000-0593(2017)07-2273-05
- Qian, S., Chen, H., Xu, Y., Su, L. (2018). High sensitivity detection of partial discharge acoustic emission within power transformer by sagnac fiber optic sensor. IEEE Transactions on Dielectrics and Electrical Insulation, 25 (6), 2313-2320. https://doi.org/10.1109/TDEI.2018.007131
- Dudani, K., Chudasama, A. R. (2016). Partial discharge detection in transformer using adaptive grey wolf optimizer based acoustic emission technique. Cogent Engineering, 3 (1). https://doi.org/10.1080/23311916.2016.1256083
- Kundu, P., Kishore, N. K., Sinha, A. K. (2009). A non-iterative partial discharge source location method for transformers employing acoustic emission techniques. Applied Acoustics, 70 (11-12), 1378-1383. https://doi.org/10.1016/j.apacoust.2009.07.001
- Kunicki, M. (2020). Analysis on acoustic disturbance signals expected during partial discharge measurements in power transformers. Archives of Acoustics, 45 (4), 733-746. https://doi.org/10.24425/aoa.2020.135279
- Gacek, Z., Szadkowski, M., Malitowski, G., Witos, F. (2010). Analysis of partial discharge in oil filled power transformer with electro-acoustic method. Przeglad Elektrotechniczny, 86 (11B), 287-290.
- Hekmati, A. (2015). Proposed method of partial discharge allocation with acoustic emission sensors within power transformers. Applied Acoustics 100, 26-33. https://doi.org/10.1016/j.apacoust.2015.07.011
- Stumberger, G., Dezelak, K., Klopcic, B., Dolinar, D. (2012). The impact of the voltage generation method on acoustic noise emissions caused by a welding transformer. IEEE Transactions on Magnetics, 48 (4), 1669-1672. https://doi.org/10.1109/TMAG.2011.2172586
- Nicoara, T., Marinescu, A., Patru, I. (2016). Partial discharge diagnostics in power and instrument transformer based on acoustic emission method. In International Conference on Applied and Theoretical Electricity (ICATE). IEEE. https://doi.org/10.1109/ICATE.2016.7754675
- Sikorski, W. (2019). Development of acoustic emission sensor optimized for partial discharge monitoring in power transformers. Sensors, 19 (8), 1865. https://doi.org/10.3390/s19081865
- Najafi, S., Peimankar, A., Saadati, H., Gockenbach, E., Borsi, H. (2013). The influence of corona near to the bushing of a transformer on partial discharge measurement with an acoustic emission sensor. In IEEE Electrical Insulation Conference (EIC). IEEE, 295-298. https://doi.org/10.1109/EIC.2013.6554253
- Kanakambaran, S., Sarathi, R., Srinivasan, B. (2018). Robust classification of partial discharges in transformer insulation based on acoustic emissions detected using fiber Bragg gratings. IEEE Sensors Journal, 18 (24), 10018-10027. https://doi.org/10.1109/JSEN.2018.2872826
- Sikorski, W., Walczak, K., Moranda, H., Gil, W., Andrzejewski, M. (2012). Partial discharge on-line monitoring system based on acoustic emission method - operational experiences. Przeglad Elektrotechniczny, 88 (11B), 117-121.
- Ludwikowski, K., Siodla, K., Ziomek, W. (2012). Investigation of transformer model winding deformation using sweep frequency response analysis. IEEE Transactions on Dielectrics and Electrical Insulation, 19 (6), 1957-1961. https://doi.org/10.1109/TDEI.2012.6396953
- Cheng, X. B., Wang, F. K. (2018). The performance of EWMA median and CUSUM median control charts for a normal process with measurement errors. Quality and Reliability Engineering International, 34 (2), 203-213. https://doi.org/10.1002/qre.2248
- Tran, K. P., Castagliola, P., Balakrishnan, N. (2017). On the performance of shewhart median chart in the presence of measurement errors. Quality and Reliability Engineering International, 33 (5), 1019-1029. https://doi.org/10.1002/qre.2087
- Cheng, X. B., Wang, F. K. (2018). VSSI median control chart with estimated parameters and measurement errors. Quality and Reliability Engineering International, 34 (5), 867-881. https://doi.org/10.1002/qre.2297
- Bucci, G., Ciancetta, F., Fioravanti, A., Fiorucci, E., Prudenzi, A. (2020). Application of SFRA for diagnostics on medical isolation transformers. International Journal of Electrical power & Energy Systems, 117, 105602. https://doi.org/10.1016/j.ijepes.2019.105602
- Ibrahim, K. H., Korany, N. R., Saleh, S. M. (2022). Effects of power transformer high-frequency equivalent circuit parameters non-uniformity on fault diagnosis using SFRA test. Ain Shams Engineering Journal, 13 (4), 101674. https://doi.org/10.1016/j.asej.2021.101674
DOI: https://doi.org/10.2478/msr-2023-0020 | Journal eISSN: 1335-8871
Language: English
Page range: 154 - 162
Submitted on: Jan 20, 2023
Accepted on: Jun 27, 2023
Published on: Sep 21, 2023
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open
Related subjects:
© 2023 Miroslav Gutten, Daniel Korenciak, Martin Karman, Peter Brncal, Matej Kucera, Tomasz N. Koltunowicz, Maciej Sulowicz, published by Slovak Academy of Sciences, Institute of Measurement Science
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.