Have a personal or library account? Click to login
A Novel Three-Head Ultrasonic System for Distance Measurements Based on the Correlation Method Cover

A Novel Three-Head Ultrasonic System for Distance Measurements Based on the Correlation Method

Open Access
|Dec 2014

Abstract

A novel double-emitter ultrasonic system for distance measurements based on the correlation method is presented. The proposed distance measurement method may be particularly useful in difficult conditions, e.g. for media parameters undergoing fast changes or in cases when obstacles and mechanical interference produce false reflections. The system is a development of a previously studied single-head idea. The present article covers a comparison of the two systems in terms of efficiency and precision. Experimental research described in this paper indicated that adding the second head improved the measurement exactness – standard deviation decreased by 40%. The correlation method is also described in detail, also giving the criterion for the quality of the measurement signal.

Language: English
Page range: 331 - 336
Submitted on: Mar 14, 2014
|
Accepted on: Nov 10, 2014
|
Published on: Dec 15, 2014
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2014 Krzysztof Gądek, Marek Dudzik, Anna Stręk, published by Slovak Academy of Sciences, Institute of Measurement Science
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.