Have a personal or library account? Click to login
Confinement effectiveness of CFRP strengthened ultra-high performance concrete cylinders exposed to elevated temperatures Cover

Confinement effectiveness of CFRP strengthened ultra-high performance concrete cylinders exposed to elevated temperatures

Open Access
|Feb 2022

References

  1. Habel K, Viviani M, Denarié E, Brühwiler E. Development of the mechanical properties of an Ultra-High Performance Fiber Reinforced Concrete (UHPFRC). Cem Concr Res. 2006;36:1362–70. https://doi.org/10.1016/J.CEMCONRES.2006.03.009
  2. Ahmad S, Rasul M, Adekunle SK, Al-Dulaijan SU, Maslehuddin M, Ali SI. Mechanical properties of steel fiber-reinforced UHPC mixtures exposed to elevated temperature: Effects of exposure duration and fiber content. Compos Part B. 2019;168:291–301. https://doi.org/10.1016/J.COMPOSITESB.2018.12.083
  3. Guler S, Yavuz D, Korkut F, Ashour A. Strength prediction models for steel, synthetic, and hybrid fiber reinforced concretes. Struct Concr. 2019;20:428–45. https://doi.org/10.1002/SUCO.201800088
  4. Abadel A, Abbas H, Almusallam T, Al-Salloum Y, Siddiqui N. Mechanical properties of hybrid fibre-reinforced concrete – analytical modelling and experimental behaviour. Mag Concr Res. 2016;68:823–43. https://doi.org/10.1680/JMACR.15.00276
  5. Guler S, Yavuz D, Aydın M. Hybrid fiber reinforced concrete-filled square stub columns under axial compression. Eng Struct. 2019;198:109504. https://doi.org/10.1016/J.ENGSTRUCT.2019.109504
  6. Guler S, Akbulut ZF, Siad H, Lachemi M. Effect of macro polypropylene, polyamide and steel fibers on the residual properties of SCC at ambient and elevated temperatures. Constr Build Mater. 2021;289:123154 https://doi.org/10.1016/J.CONBUILDMAT.2021.123154
  7. Abadel A, Elsanadedy H, Almusallam T, Alaskar A, Abbas H, Al-Salloum Y. Residual compressive strength of plain and fiber reinforced concrete after exposure to different heating and cooling regimes. Eur J Environ Civ Eng. 2021;1–20. https://doi.org/10.1080/19648189.2021.1960898
  8. Poon CS, Azhar S, Anson M, Wong YL. Comparison of the strength and durability performance of normal- and high-strength pozzolanic concretes at elevated temperatures. Cem Concr Res. 2001;31:1291–300. https://doi.org/10.1016/S0008-8846(01)00580-4
  9. Bastami M, Chaboki-Khiabani A, Baghbadrani M, Kordi M. Performance of high strength concretes at elevated temperatures. Sci Iran. 2011;18:1028–36. https://doi.org/10.1016/J.SCIENT.2011.09.001
  10. Khan MS, Abbas H. Performance of concrete subjected to elevated temperature. Eur J Environ Civ Eng. 2015;20:532–43. https://doi.org/10.1080/19648189.2015.1053152
  11. Kalifa P, Chéné G, Gallé C. High-temperature behaviour of HPC with polypropylene fibres: From spalling to microstructure. Cem Concr Res. 2001;31:1487–99. https://doi.org/10.1016/S0008-8846(01)00596-8
  12. Bangi MR, Horiguchi T. Effect of fibre type and geometry on maximum pore pressures in fibre-reinforced high strength concrete at elevated temperatures. Cem Concr Res. 2012;42:459–66. https://doi.org/10.1016/J.CEMCONRES.2011.11.014
  13. Almusallam T, Ibrahim SM, Al-Salloum Y, Abadel A, Abbas H. Analytical and experimental investigations on the fracture behavior of hybrid fiber reinforced concrete. Cem Concr Compos. 2016;74:201–17. https://doi.org/10.1016/J.CEMCONCOMP.2016.10.002
  14. Yermak N, Pliya P, Beaucour AL, Simon A, Noumowé A. Influence of steel and/or polypropylene fibres on the behaviour of concrete at high temperature: Spalling, transfer and mechanical properties. Constr Build Mater. 2017;132:240–50. https://doi.org/10.1016/J.CONBUILDMAT.2016.11.120
  15. Noumowé A, Carré H, Daoud A, Toutanji H. High-strength self-compacting concrete exposed to fire test. J Mater Civ Eng. 2006;18:754–8. https://doi.org/10.1061/(ASCE)0899-1561(2006)18:6(754)
  16. Phan L. Spalling and mechanical properties of high strength concrete at high temperature. Actes Des Journées Scientifiques Du LCPC. 2007:1595–608.
  17. Chan SY, Peng GF, Chan JK. Comparison between high strength concrete and normal strength concrete subjected to high temperature. Mater Struct. 1996;29:616–9. https://doi.org/10.1007/BF02485969
  18. Aslani F, Bastami M. Constitutive relationships for normal-and high-strength concrete at elevated temperatures. ACI Mater J. 2011;108:355–64. https://doi.org/10.14359/51683106
  19. Lau A, Anson M. Effect of high temperatures on high performance steel fibre reinforced concrete. Cem Concr Res. 2006;36:1698–707. https://doi.org/10.1016/J.CEMCONRES.2006.03.024
  20. Varona FB, Baeza FJ, Bru D, Ivorra S. Influence of high temperature on the mechanical properties of hybrid fibre reinforced normal and high strength concrete. Constr Build Mater. 2018;159:73–82. https://doi.org/10.1016/J.CONBUILDMAT.2017.10.129
  21. Elsanadedy HM, Al-Salloum YA, Alsayed SH, Iqbal RA. Experimental and numerical investigation of size effects in FRP-wrapped concrete columns. Constr Build Mater. 2012;29:56–72. https://doi.org/10.1016/J.CONBUILDMAT.2011.10.025
  22. Al-Salloum YA, Al-Amri GS, Siddiqui NA, Almusallam TH, Abbas H. Effectiveness of CFRP strengthening in improving cyclic compression response of slender RC columns. J Compos Constr. 2018;22:04018009. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000842
  23. Thériault M, Neale KW. Design equations for axially loaded reinforced concrete columns strengthened with fibre reinforced polymer wraps. Can J Civ Eng. 2011;27:1011–20. https://doi.org/10.1139/L00-019
  24. Demers M, Neale KW. Confinement of reinforced concrete columns with fibre-reinforced composite sheets - an experimental study. Can J Civ Eng. 2011;26:226–41. https://doi.org/10.1139/L98-067
  25. Al-Salloum YA, Almusallam TH, Elsanadedy HM, Iqbal RA. Effect of elevated temperature environments on the residual axial capacity of RC columns strengthened with different techniques. Constr Build Mater. 2016;115:345–61. https://doi.org/10.1016/J.CONBUILDMAT.2016.04.041
  26. Abadel AA, Khan MI, Masmoudi R. Axial capacity and stiffness of post-heated circular and square columns strengthened with carbon fiber reinforced polymer jackets. Structures. 2021;33:2599–610. https://doi.org/10.1016/J.ISTRUC.2021.05.081
  27. Alrshoudi F, Abbas H, Abadel A, Albidah A, Altheeb A, Al-Salloum Y. Compression behavior and modeling of FRP-confined high strength geopolymer concrete. Constr Build Mater. 2021;283:122759. https://doi.org/10.1016/J.CONBUILDMAT.2021.122759
  28. Mandal S, Hoskin A, Fam A. Influence of concrete strength on confinement effectiveness of fiber-reinforced polymer circular jackets. Struct J. 2005;102:383–92. https://doi.org/10.14359/14409
  29. Cui C, Sheikh SA. Experimental study of normal- and high-strength concrete confined with fiber-reinforced polymers. J Compos Constr. 2010;14:553–61. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000116
  30. Zohrevand P, Mirmiran A. Behavior of ultrahigh-performance concrete confined by fiber-reinforced polymers. J Mater Civ Eng. 2011;23:1727–34. https://doi.org/10.1061/(ASCE)MT.1943-5533.0000324
  31. Saiidi MS, O'Brien M, Sadrossadat-Zadeh M. Cyclic response of concrete bridge columns using superelastic nitinol and bendable concrete. Struct J. 2009;106:69–77. https://doi.org/10.14359/56285
  32. Wang W, Wu C, Liu Z, Si H. Compressive behavior of ultra-high performance fiber-reinforced concrete (UHPFRC) confined with FRP. Compos Struct. 2018;204:419–37. https://doi.org/10.1016/J.COMPSTRUCT.2018.07.102
  33. Lam L, Huang L, Xie JH, Chen JF. Compressive behavior of ultra-high performance concrete confined with FRP. Compos Struct. 2021;274:114321. https://doi.org/10.1016/J.COMPSTRUCT.2021.114321
  34. Khan MS, Prasad J, Abbas H. Shear strength of RC beams subjected to cyclic thermal loading. Constr Build Mater. 2010;24:1869–77. https://doi.org/10.1016/J.CONBUILDMAT.2010.04.016
  35. Khan MS, Prasad J, Abbas H. Bond strength of RC beams subjected to cyclic thermal loading. Constr Build Mater. 2013;38:644–57. https://doi.org/10.1016/J.CONBUILDMAT.2012.09.018
  36. ISO. Fire-resistance tests – elements of building construction – part 1: General requirements. vol. ISO 834-1: 1999.
  37. ASTM-C39. Standard test method for compressive strength of cylindrical concrete. Annual Book of ASTM Standards 2010. https://doi.org/D.O.I:10.1520/C0039_C0039M-10
  38. Komonen J, Penttala V. Effects of high temperature on the pore structure and strength of plain and polypropylene fiber reinforced cement pastes. Fire Technol. 2003;39:23–34. https://doi.org/10.1023/A:1021723126005
DOI: https://doi.org/10.2478/msp-2021-0040 | Journal eISSN: 2083-134X | Journal ISSN: 2083-1331
Language: English
Page range: 478 - 490
Submitted on: Nov 20, 2021
Accepted on: Jan 12, 2022
Published on: Feb 23, 2022
Published by: Wroclaw University of Science and Technology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2022 Aref A. Abadel, Yousef R. Alharbi, published by Wroclaw University of Science and Technology
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.