Abstract

The paper presents the results of tests on single shear bolted connections of cold-formed steel sections with a wall thickness of 4 mm made with standard fully threaded M16 grade 8.8 bolts. The tests were performed for connections with washers and without washers. The obtained results were referred to earlier studies of analogous connections using blind fasteners Huck BOM R16. The failure mode was identified, the load capacity and stiffness were compared, and a method to determine the non-linear load-displacement characteristics of such connections was proposed. The effect of stiffness of joints on structural response of exemplary cold-formed steel frame was shown.

DOI: https://doi.org/10.21307/acee-2020-023 | Journal eISSN: 2720-6947 | Journal ISSN: 1899-0142
Language: English
Page range: 45 - 60
Submitted on: Apr 11, 2020
Accepted on: Jul 29, 2020
Published on: Oct 31, 2020
Published by: Silesian University of Technology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2020 Szymon SWIERCZYNA, published by Silesian University of Technology