Have a personal or library account? Click to login
Proposed Use of Monte Carlo Simulated Images to Evaluate the Accuracy of Measurements on X-Ray Computed Tomography Cover

Proposed Use of Monte Carlo Simulated Images to Evaluate the Accuracy of Measurements on X-Ray Computed Tomography

Open Access
|Nov 2018

References

  1. [1] Maire, E., Withers, P.J. (2014). Quantitative X-ray tomography. International Materials Reviews, 59 (1), 1-43.10.1179/1743280413Y.0000000023
  2. [2] Kruth, J.P., Bartscher, M., Carmignato, S., Schmitt, R., De Chiffre, L., Weckenmann, A. (2011). Computed tomography for dimensional metrology. CIRP Annals-Manufacturing Technology, 60 (2), 821-842.10.1016/j.cirp.2011.05.006
  3. [3] De Chiffre, L., Carmignato, S., Kruth, J.P., Schmitt, R., Weckenmann, A. (2014). Industrial applications of computed tomography. CIRP Annals-Manufacturing Technology, 63, 655-677.10.1016/j.cirp.2014.05.011
  4. [4] Villarraga-Gómez, H. (2016). X-ray computed tomography for dimensional measurements. In Digital Imaging 2016: ASNT Topical Conference, Mashantucket, CT, USA. American Society for Nondestructive Testing, 44-57.
  5. [5] Villarraga-Gómez, H. (2016). Seeing is believing: Xray computed tomography for quality control. Quality Magazine, 55 (6), 20-23.
  6. [6] Villarraga-Gómez, H., Lee, C., Corbett, T., Tarbutton, J.A., Smith, S.T. (2015). Assessing additive manufacturing processes with X-ray CT metrology. In ASPE Spring Topical Meeting, Raleigh, NC, USA. Vol. 60, 116-120.
  7. [7] Gapinski, B., Wieczorowski, M., Marciniak-Podsadna, L., Dybala, B., Ziolkowski, G. (2013). Comparison of different method of measurement geometry using CMM, optical scanner and computed tomography 3D. In 24th DAAAM International Symposium on Intelligent Manufacturing and Automation.
  8. [8] Hermanek, P., Carmignato, S. (2016). Reference object for evaluating the accuracy of porosity measurements by X-ray computed tomography. Case Studies in Nondestructive Testing and Evaluation, 6, 122-127.10.1016/j.csndt.2016.05.003
  9. [9] Kiekens, K., Welkenhuyzen, F., Tan, Y., Bleys, P., Voet, A., Kruth, J.-P., Dewulf, W. (2011). A test object with parallel grooves for calibration and accuracy assessment of industrial computed tomography (CT) metrology. Measurement Science and Technology, 22 (11), 115502.10.1088/0957-0233/22/11/115502
  10. [10] Obrist, A., Flisch, A., Hofmann, J. (2004). Point cloud reconstruction with sub-pixel accuracy by sliceadaptive thresholding of X-ray computed tomography images. NDT & E International, 37, 373-380.10.1016/j.ndteint.2003.11.002
  11. [11] Kowaluk, T., Wozniak, A. (2017). A new threshold selection method for X-ray computed tomography for dimensional metrology. Precision Engineering, 50, 449-454.10.1016/j.precisioneng.2017.06.020
  12. [12] Battistoni, G., Muraro, S., Sala, P.R., Cerutti, F., Ferrari, A., Roesler, S., Fasso, A., Ranft, J. (2007). The FLUKA code: Description and benchmarking. In AIP Conference Proceedings of the Hadronic Shower Simulation Workshop 2006, 6-8 September 2006. AIP, Vol. 896, 31-49.10.1063/1.2720455
  13. [13] Böhlen, T.T., Cerutti, F., Chin, M.P.W., Fassò, A., Ferrari, A., Ortega, P.G., Mairani, A., Sala, P.R., Smirnov, G., Vlachoudis, V. (2014). The FLUKA Code: Developments and challenges for high energy and medical applications. Nuclear Data Sheets, 120, 211-214.10.1016/j.nds.2014.07.049
  14. [14] Hamamatsu Photonics K.K. 130 kV Microfocus X-Ray Source, L9181-02. Instruction Manual. https://www.hamamatsu.com/resources/pdf/etd/L9181-02_TXPR1015E.pdf.
  15. [15] Berdondinia, A., Bettuzzia, M., Bianconia, D., Brancaccioa, R. (2007). Monte Carlo optimization of an industrial tomography system. Nuclear Instruments and Methods in Physics Research A, 580, 771-773.10.1016/j.nima.2007.05.104
  16. [16] Sladek, J., Gaska, A. (2012). Evaluation of coordinate measurement uncertainty with use of virtual machine model based on Monte Carlo method. In Measurement, 45 (6), 1564-1575.
  17. [17] Hiller, J., Reindl, L. (2012). A computer simulation platform for the estimation of measurement uncertainties in dimensional X-ray computed tomography. Measurement, 45 (8), 2166-2182.10.1016/j.measurement.2012.05.030
  18. [18] Miceli, A., Thierrya, R., Flischa, A., Sennhausera, U., Casalib, F., Simonc, M. (2007). Monte Carlo simulations of a high-resolution X-ray CT system for industrial applications. Nuclear Instruments and Methods in Physics Research A, 583, 313-323.10.1016/j.nima.2007.09.012
  19. [19] Chyba, B., Mantler, M., Reiter, M. (2008). Monte Carlo simulation of projections in computed tomography powder diffraction. Powder Diffraction, 23 (2), 150-153.10.1154/1.2919045
  20. [20] Vlachoudis, V. (2009). FLAIR: A powerful but user friendly graphical interface for FLUKA. In International Conference on Mathematics, Computational Methods & Reactor Physics (M&C 2009), Saratoga Springs, New York, 3-7 May 2009. American Nuclear Society.
Language: English
Page range: 251 - 255
Submitted on: May 8, 2018
Accepted on: Nov 3, 2018
Published on: Nov 30, 2018
Published by: Slovak Academy of Sciences, Institute of Measurement Science
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2018 Tomasz Kowaluk, Maciej Maciak, Adam Woźniak, Piotr Tulik, Natalia Golnik, published by Slovak Academy of Sciences, Institute of Measurement Science
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.