Skip to main content
Have a personal or library account? Click to login
Probing System Characteristics in Coordinate Metrology Cover

Probing System Characteristics in Coordinate Metrology

By:   
Open Access
|Oct 2010

References

  1. Weckenmann, A., Estler, T., Peggs, G., McMurtry, D. (2004). Probing systems in dimensional metrology. CIRP Annals-Manufacturing Technology, 53 (2), 657-684.
  2. Woźniak, A., Dobosz, M. (2005). Influence of measured objects parameters on CMM touch trigger probe accuracy of probing. Precision Engineering, 29 (3), 290-297.
  3. Woźniak, A., Mayer, J. R. R., Bałaziński, M. (2009). Stylus tip envelop method: corrected measured point determination in high definition coordinate metrolog. Int. Journal of Advanced Manufacturing Technology, 42, 505-514.
  4. Wu, Y., Liu, S., Zhang, G. (2004). Improvement of coordinate measuring machine probing accessibility. Precision Engineering, 28 (1), 89-94.
  5. Park, J.-J., Kwon, K., Cho, N. (2006). Development of a coordinate measuring machine (CMM) touch probe using a multi-axis force sensor. Measurement Science and Technology, 17, 2380-2386.
  6. Hermann, G. (2007). Geometric error correction in coordinate measurement. Acta Polytechnica Hungarica, 4 (1), 47-62.
  7. Schwenke, H., Knapp, W., Haitjema, H., Weckenmann, A., Schmitt, R., Delbressine, F. (2008). Geometric error measurement and compensation of machines-an update. CIRP Annals-Manufacturing Technology, 57, 660-675.
  8. Genest, D. H. (1997). The right probe system adds versatility to CMMs. Quality Digest, http://www.qualitydigest.com/jan97/probes.html
  9. Dobosz, M., Woźniak, A. (2005). CMM touch trigger probes testing using a reference axis. Precision Engineering, 29 (3), 281-289.
  10. Zeiss Calypso Navigator (2004). CMM Operation Instructions and Training Manual. Revision 4.0. Oberkochen, Germany: Carl Zeiss Co.
  11. Ali, S. H. R. (2008) The Influence of fitting algorithm and scanning speed on roundness error for 50 mm standard ring measurement using CMM. Journal of Metrology & Measurement Systems, 15 (1), 31-53.
  12. Kasparaitis, A., Šukys, A. (2006). Dynamic errors of CMM probes. Solid State Phenomena: Mechatronic Systems and Materials, 113, 477-482.
  13. Ali, S. H.R, Mohamed, H. H., Bedewy, M. K. (2009). Identifying cylinder liner wear using precise coordinate measurements. Int. Journal of Precision Engineering and Manufacturing, 10 (5), 19-25.
  14. Lin, Y. C., Sun, W. I. (2003). Probe radius compensated by the multi-cross product method in free form surface measurement with touch trigger probe CMM. Int. Journal of Advanced Manufacturing Technology, 21, 902-909.
  15. Li, L., Jung, J.-Y., Lee, CH.-M., Chung, W.-J. (2003). Compensation of probe radius in measuring freeformed curves and surface. Int. Journal of the Korean Society of Precision Engineering, 4 (3).
  16. Xiong, Z., Li, Z. (2003). Probe radius compensation of workpiece localization. Transactions of the ASME, 125, 100-104.
  17. Ali, S. H. R. (2010). Two dimensional model of CMM probing system. Journal of Automation, Mobile Robotics & Intelligent Systems, 4 (2), 3-7.
  18. Sokovic, M., Cedilnik, M., Kopac, J. (2007). Identification of scanning errors using touch trigger probe head. Journal of Achievements in Materials and Manufacturing Engineering, 20 (1-2), 383-386.
  19. Estler, W. T., Phillips, S. D., Borchardt, B., Hopp, T., Witzgall, C., Levenson, M., Eberhardt, K., McClain, M., Shen, Y., Zhang, X. (1996). Error compensation for CMM touch trigger probes. Precision Engineering, 19 (2), 85-97.
  20. Pereira, P. H., Hocken, R. J. (2007). Characterization and compensation of dynamic errors of a scanning coordinate measuring machine. Precision Engineering, 31(1), 22-32.
  21. Hessling, J. P. (2008). Dynamic metrology - an approach to dynamic evaluation of linear timeinvariant measurement systems. Measurement Science and Technology, 19 (8).
  22. Farooqui, A., Morse, P. (2007). Methods and artifacts for comparison of scanning CMM performance. Transactions of the ASME, 7, 72-80.
  23. Kosarevsky, S., Latypov, V. (2010). Inertia compensation while scanning screw threads on coordinate measurement machines. Measurement Science Review, 10 (2), 68-71.
  24. Yagüe, J.-A., Albajez, J.-A., Velázquez, J., Aguilar, J.-J. (2009). A new out-of-machine calibration technique for passive contact analog probes. Measurement, 42, 346-357.
  25. Zhao, J., Fei, Y. T., Chen, X. H., Wang, H. T. (2005). Research on high-speed measurement accuracy of coordinate measuring machines. Journal of Physics: Conference Series, 13, 167-170.
  26. Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines (CMM) - Part 2: CMMs used for measuring linear dimensions. (2009). Standard ISO 10360-2.
  27. Beaman, J., Morse, E. (2010). Experimental evaluation of software estimates of task specific measurement uncertainty for CMMs. Precision Engineering, 34, 28-33.
Language: English
Page range: 120 - 129
Published on: Oct 28, 2010
Published by: Slovak Academy of Sciences, Institute of Measurement Science
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2010 Salah Ali, published by Slovak Academy of Sciences, Institute of Measurement Science
This work is licensed under the Creative Commons License.