Have a personal or library account? Click to login
Frequency Selective Control of a Parallel Active Filter with Resonance Filter Regulators Cover

Frequency Selective Control of a Parallel Active Filter with Resonance Filter Regulators

By: O. Krievs and  L. Ribickis  
Open Access
|Mar 2009

References

  1. Bhattacharya, S., Divan, D.M., & Banerjee, B. (1995). Active Filter Solutions for Utility Interface. Conf. Rec. IEEE ISIE. pp. 53-63.10.1109/ISIE.1995.496477
  2. Sasaki, H., & Machida, T. (1971). A new method to eliminate AC harmonic currents by magnetic compensation - considerations on basic design. IEEE Trans. on PAS, 90 (5), 2009-2011.10.1109/TPAS.1971.292996
  3. Krievs, O., Galkin, I., & Riberio, R.L.A. (2003). Design Considerations for the Power Circuit of a Shunt Active Power Filter. Proceedings of RTU Sci. Conf. Ser. 4. Vol. 10. p. 52.
  4. Kazmierkowski, M.P., & Malesani, L. (1998). Current Control Techniques for Three-Phase Voltage-Source PWM Converters: a Survey. IEEE Trans. on Industrial Electronics, 45 (5), 691-703.10.1109/41.720325
  5. Bojrup, M., Karlsson, P., Alakula, M., & Gertmar, L. (1999). A multiple rotating integrator controller for active filters. Conf. Rec. EPE, CDROM.
  6. Gonzalo, G., Salvia, A., Briozzo, C., & Watanabe, E.H. (2002). Control Strategy of Selective Harmonic Current Shunt Active Filter. IEEE Proceedings of Generation Transmission and Distribution. 149 (2), 689-694.
  7. Gonzalo, G., Salvia, A., Briozzo, C., & Watanabe, E.H. (2004). Selective Filter with Optimum Remote Harmonic Distortion Control. IEEE Transactions on Power Delivery, 19 (4), 1990-1997.
  8. Matavelli, P. (2001). A Closed-Loop Selective Harmonic Compensation for Active Filters. IEEE Transactions on Industrial Applications, 37 (1), 81-89.10.1109/28.903130
  9. Sonnenschein, M., Weinhold, M., & Zurowski, R. (1996). Shunt-Connected Power Conditioner for Improvement of Power Quality in Distribution Networks. Conf. Rec., 7th International Conference on Harmonics and Quality of Power. 27-32.
  10. Yuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002). Stationary-Frame Generalized Integrators for Current Control of Active Power Filters with Zero Steady-State Error for Current Harmonics of Concern under Unbalanced and Distorted Operating Conditions. IEEE Trans. on Industry Applications. 38 (2), 523-532.10.1109/28.993175
  11. Akagi H., Watanabe E.H., & Aredes M. (2007). Instantaneous Power Theory and Applications to Power Conditioning. New Jersey (USA): John Wiley & Sons, 379 p.10.1002/0470118938
DOI: https://doi.org/10.2478/v10047-009-0001-6 | Journal eISSN: 2255-8896 | Journal ISSN: 0868-8257
Language: English
Page range: 3 - 14
Published on: Mar 20, 2009
Published by: Institute of Physical Energetics
In partnership with: Paradigm Publishing Services
Publication frequency: 6 issues per year

© 2009 O. Krievs, L. Ribickis, published by Institute of Physical Energetics
This work is licensed under the Creative Commons License.

Volume 46 (2009): Issue 1 (February 2009)