Have a personal or library account? Click to login
Electrocoagulation of model wastewater using aluminum electrodes Cover

Electrocoagulation of model wastewater using aluminum electrodes

Open Access
|Oct 2012

Abstract

Electrocoagulation makes an alternative method to chemical coagulation. This paper presents the results obtained during the electrocoagulation of the model wastewater using aluminum electrodes. The wastewater was treated by means of chronopotentiometric electrocoagulation process in a static system, at the constant current I = 0.3 A; therefore higher doses of electrocoagulant required longer electrocoagulation time. Changes in zeta potential, pH, turbidity, chemical oxygen demand (COD), suspended solids and total phosphorus concentrations in the treated wastewater were determined. A new method for determining the optimal dosage of the aluminum electrocoagulant was proposed through application of the third degree polynomial function rather than the parabolic equation. An increase in the electrocoagulant dose raised the share of sweep fl occulation in the studied treatment process, resulting in the effective removal over 90% of phosphorus compounds from the system.

Language: English
Page range: 66 - 70
Published on: Oct 31, 2012
Published by: West Pomeranian University of Technology, Szczecin
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2012 Lech Smoczyński, Kamilla Teresa Muńska, Bogusław Pierożyński, Marta Kosobucka, published by West Pomeranian University of Technology, Szczecin
This work is licensed under the Creative Commons License.