Have a personal or library account? Click to login
Analysis of fouling thermal resistance of feed-water heaters in steam power plants Cover

Analysis of fouling thermal resistance of feed-water heaters in steam power plants

Open Access
|Jun 2010

Abstract

In this paper a problem is discussed of thermal degradation of shell-and-tube recuperative feed-water heaters due to heat transfer surface fouling. Application (to an example steam cycle of power plant) of DIAGAR software system intended for the analysing of impact of degradation of a particular heat exchanger on whole recuperative system performance, is presented. On the basis of the systematically performed simulative calculations it was concluded that the degradation of feed-water heaters of the lowest extraction pressure results in an additional load imposed on the heaters of higher extraction pressures, moreover it was estimated that the degradation of the heaters due to presence of sediments of the thermal resistance reaching 5*10-4 m2*K/W, has resulted in the drop of turbine set efficiency by about 0.3%. Such drop depends on a given configuration of degree of degradation of particular feed-water heaters applied in a considered turbine set.

DOI: https://doi.org/10.2478/v10012-008-0037-1 | Journal eISSN: 2083-7429 | Journal ISSN: 1233-2585
Language: English
Page range: 3 - 8
Published on: Jun 16, 2010
Published by: Gdansk University of Technology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2010 Dariusz Butrymowicz, Jerzy Głuch, Tomasz Hajduk, Marian Trela, Andrzej Gardzilewicz, published by Gdansk University of Technology
This work is licensed under the Creative Commons License.