Abstract

Based on the results of author's research it was stated that significant differences between heat release rates measured according to ISO 5660-1 and FTP Code Part 5 (Res. A. 653 (16)) are not caused by measurement uncertainties. A basic factor determining the lack of correlation is treating the heat release rate in the category of static measurements in the normalized measurement methods. Taking into account dynamic parameters of the test station allowed the coincidence rate (reproducibility and correlation) of the results of heat release rates measured using different methods to be improved, without changing test stations and procedures. Author's research performed on 42 materials has revealed that the relative dynamic errors of the heat release rate measurements are significant (2%÷120%). The average value of these changes for the tested group of materials was equal to 39%.

DOI: https://doi.org/10.2478/v10012-007-0052-7 | Journal eISSN: 2083-7429 | Journal ISSN: 1233-2585
Language: English
Page range: 56 - 59
Published on: Jun 10, 2008
Published by: Gdansk University of Technology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2008 Krzysztof Sychta, published by Gdansk University of Technology
This work is licensed under the Creative Commons License.