Have a personal or library account? Click to login
Accuracy of transthoracic echocardiography in diagnosis of cardiac myxoma: single center experience Cover

Accuracy of transthoracic echocardiography in diagnosis of cardiac myxoma: single center experience

Open Access
|Jan 2025

Abstract

Background

The differential diagnosis of cardiac myxomas (CM), the most common benign primary cardiac tumors, is broad and a thorough diagnostic workup is required to establish accurate diagnosis prior to surgical resection. Transthoracic echocardiography (TTE) is usually the first imaging modality used for diagnosis of suspected CM. In a single tertiary centre study, we sought to determine the accuracy, sensitivity, and specificity of TTE in the diagnosis of CM and to determine echocardiographic characteristics indicative of CM.

Patients and methods

We retrospectively analyzed clinical, echocardiographic, and pathohistological findings of 73 patients consecutively admitted for suspected CM.

Results

After diagnostic workup, 53 (73%) patients were treated surgically at our institution. Based on preoperative TTE, patients were divided into a CM group (n=45, 85%) and non-myxoma (NM) group. Of the 53 pathohistological specimens obtained during surgery, 39 (73%) were CM. The sensitivity and specificity of preoperative echocardiography were 97% and 50%, respectively. The overall accuracy was 85%. All NM tumors were found in an atypical location and 72% of CM were found in a typical position in the left atrium (p < 0.001). Tumors in NM group were significantly smaller than CM (24.3 ± 13.2 mm vs. 37.9 ± 18.3 mm, p = 0.017).

Conclusions

Our study confirms very good accuracy of TTE in the diagnosis of CM. The most important echocardiographic characteristics to differentiate between CM and tumors of different etiology are tumor location and size. Smaller tumors presenting at an atypical location are less likely to be diagnosed as CM, and these require additional imaging modalities for accurate diagnosis.

DOI: https://doi.org/10.2478/raon-2025-0007 | Journal eISSN: 1581-3207 | Journal ISSN: 1318-2099
Language: English
Page range: 63 - 68
Submitted on: Feb 10, 2024
|
Accepted on: Dec 8, 2024
|
Published on: Jan 22, 2025
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2025 Polona Kacar, Nejc Pavsic, Mojca Bervar, Zvezdana Dolenc Strazar, Katja Prokselj, published by Association of Radiology and Oncology
This work is licensed under the Creative Commons Attribution 4.0 License.