References
- Crijns W, Maes F, van der Heide UA, V den Heuvel F. Calibrating page sized Gafchromic EBT3 films. Med Phys 2013; 40: 012102. doi: 10.1118/1.4771960
- Niroomand-Rad A, Blackwell CR, Coursey BM, Gall KP, Galvin JM, McLaughlin WL, et al. Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55. Med Phys 1998; 25: 2093115. doi: 10.1118/1.598407
- Rink A, Vitkin IA, Jaffray DA. Energy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real-time optical dosimeter. Med Phys 2007; 34: 458-63. doi: 10.1118/1.2431425
- Richter C, Pawelke J, Karsch L, Woithe J. Energy dependence of EBT-1 radiochromic film response for photon (10 kVp–15 MVp) and electron beams (6–18 MeV) readout by a flatbed scanner. Med Phys 2009; 36: 5506-14. doi: 10.1118/1.3253902
- Arjomandy B, Tailor R, Anand A, Sahoo N, Gillin M, Prado K, et al. Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies. Med Phys 2010; 37: 1942-7. doi: 10.1118/1.3253902
- Lindsay P, Rink A, Ruschin M, Jaffray D. Investigation of energy dependence of EBT and EBT-2 Gafchromic film. Med Phys 2010; 37: 571-6. doi: 10.1118/1.3291622
- Massillon-JL G, Chiu-Tsao S, Domingo-Munoz I, Chan M. Energy Dependence of the new Gafchromic EBT3 film: dose response curves for 50 KV, 6 and 15 MV x-ray beams. Int J Radiat Oncol Biol Phys 2012; 1: 60-5. doi: 10.4236/ ijmpcero.2012.12008
- Bekerat H, Devic S, DeBlois F, Singh K, Sarfehnia A, Seuntjens J, et al. Improving the energy response of external beam therapy (EBT) GafChromic dosimetry films at low energies (≤ 100 keV). Med Phys 2014; 41: 022101. doi: 10.1118/1.4860157
- León -Marroquín EY, Lárraga-Gutiérrez JM, Herrera-González JA, Camacho-López MA, Villarreal Barajas JE, Garcıá -Garduño OA. Investigation of EBT3 radiochromic film’s response to humidity. J Appl Clin Med Phys 2018; 19: 283-90. doi: 10.1002/acm2.12337
- Niroomand-Rad A, Chiu-Tsao ST, Grams MP, Lewis DF, Soares CG, Van Battum LJ, et al. Report of AAPM Task Group 235 radiochromic film dosimetry: an update to TG-55. Med Phys 2020; 47: 5986-6025. doi: 10.1002/ mp.14497
- Lozares S, Font JA, Gandía A, Campos A, Flamarique S, Ibáñez R, et al. In vivo dosimetry in low-voltage IORT breast treatments with XR-RV3 radiochromic film. Phys Med 2021; 81: 173-81. doi: 10.1016/j.ejmp.2020.12.011
- McCabe BP, Speide l MA, Pike TL, Van Lysel MS. Calibration of Gafchromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner. Med Phys 2011; 38: 1919-30. doi: 10.1118/1.3560422
- Lárraga-Gutiérrez JM, Garcıá -Garduño OA, Treviño-Palacios C, Herrera-González JA. Evaluation of a led-based flatbed document scanner for radiochromic film dosimetry in transmission mode. Phys Med 2018; 47: 86-91. doi: 10.1016/j.ejmp.2018.02.010
- González-López A, Vera-S ánchez JA, Ruiz-Morales C. The incidence of the different sources of noise on the uncertainty in radiochromic film dosimetry using single channel and multichannel methods. Phys Med Biol 2017; 62: N525-36. doi: 10.1088/1361-6560/aa8f74
- Méndez I, Šljivić Ž, Hudej R, Jenko A, Casar B. Grid patterns, spatial inter-scan variations and scanning reading repeatability in radiochromic film dosimetry. Phys Med 2016; 32: 1072-81.
- Battum L van, Huizenga H, Verdaa sdonk R, Heukelom S. How flatbed scanners upset accurate film dosimetry. Phys Med Biol 2015; 61: 625-49. doi: 10.1088/0031-9155/61/2/625.
- Lewis D, Chan MF. Correcting lat eral response artifacts from flatbed scanners for radiochromic film dosimetry. Med Phys 2015; 42: 416-29.doi: 10.1118/1.4903758.
- Lewis D, Devic S. Correcting scan-to-scan response variability for a radiochromic film-based reference dosimetry system. Med Phys 2015; 42: 5692-701. doi: 10.1118/1.4929563
- Schoenfeld AA, Poppinga D, Harde r D, Doerner KJ, Poppe B. The artefacts of radiochromic film dosimetry with flatbed scanners and their causation by light scattering from radiation-induced polymers. Phys Med Biol 2014; 59: 3575-97.doi: 10.1088/0031-9155/59/13/3575
- Alnawaf H, Yu PK, Butson M. Comparison of Epson scanner quality for radiochromic film evaluation. J Appl Clin Med Phys 2012; 13: 3957. doi: 10.1120/jacmp.v13i5.3957
- Papaconstadopoulos P, Hegyi G, S euntjens J, Devic S. A protocol for EBT3 radiochromic film dosimetry using reflection scanning. Med Phys 2014; 41: 122101. doi: 10.1118/1.4901308
- Ramos L, Perez Azorin JF. Comment on “A protocol for EBT3 radiochromic film dosimetry using reflection dosimetry using scanning” [Med Phys 41(12), 122101 (6pp.) (2014)]. Med Phys 2015; 42: 2096-7. doi: 10.1118/1.4914853
- Méndez I, Polšak A, Hudej R, Casar B. The multigaussian method: a new approach to mitigating spatial heterogeneities with multichannel radiochromic film dosimetry. Phys Med Biol 2018; 63: 175013.
- Hartmann B, Martišıḱ ová M, Jäkel O. Homogeneity of Gafchromic EBT2 film. Med Phys 2010; 37: 1753-6. doi: 10.1118/1.3368601
- Andrés C, del Castillo A, Tortosa R, Alonso D, Barquero R. A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT. Med Phys 2010; 37: 6271-8. doi: 10.1118/1.3512792
- Girard F, Bouchard H, Lacroix F. Reference dosimetry using radiochromic film. J Appl Clin Med Phys 2012; 13: 3994. doi: 10.1120/jacmp.v13i6.3994
- Rink A, Lewis DF, Varma S, Vitkin IA, Ja ffray DA. Temperature and hydration effects on absorbance spectra and radiation sensitivity of a radiochromic medium. Med Phys 2008; 35: 4545-55. doi: 10.1118/1.2975483
- Bouchard H, Lacroix F, Beaudoin G, Carrier J-F, Kawrakow I. On the characterization and uncertainty analysis of radiochromic film dosimetry. Med Phys 2009; 36: 1931-46. doi: 10.1118/1.3121488
- Van Hoof SJ, Granton PV, Landry G, Podesta M, Verhaegen F. Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2. Phys Med Biol 2012; 57: 4353–68. doi: 10.1088/0031-9155/57/13/4353
- Paelinck L, De Neve W, De Wagter C. Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry. Phys Med Biol 2007; 52: 231-42. doi: 10.1088/0031-9155/52/1/015
- Ferreira B, Lopes M, Capela M. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry. Phys Med Biol 2009; 54: 1073-85. doi: 10.1088/0031-9155/54/4/017
- Schoenfeld AA, Wieker S, Harder D, Poppe B. The origin of the flatbed scanner artifacts in radiochromic film dosimetry-key experiments and theoretical descriptions. Phys Med Biol 2016; 61: 7704-24. doi: 10.1088/00319155/61/21/7704
- Butson MJ, Cheung T, Yu P. Evaluation of the magnitude of EBT Gafchromic film polarization effects. Australas Phys Eng Sci Med 2009; 32: 21-5. doi: 10.1007/BF03178624
- Palmer AL, Bradley DA, Nisbet A. Evaluat ion and mitigation of potential errors in radiochromic film dosimetry due to film curvature at scanning. J Appl Clin Med Phys 2015; 16: 5141. doi: 10.1120/jacmp.v16i2.5141
- Dreindl R, Georg D, Stock M. Radiochromic film dosimetry: considerations on precision and accuracy for EBT2 and EBT3 type films. Z Med Phys 2014; 24: 153-63. doi: 10.1016/j.zemedi.2013.08.002
- Devic S, Aldelaijan S, Mohammed H, Tomic N, Liang LH, DeBlois F, et al. Absorption spectra time evolution of EBT-2 model Gafchromic film. Med Phys 2010; 37: 2207-14. doi: 10.1118/1.3378675
- Ruiz-Morales C, Vera-Sánchez JA, Gonzále z-López A. On the re-calibration process in radiochromic film dosimetry. Phys Med 2017; 42: 67-75. doi: 10.1016/j.ejmp.2017.08.013
- Méndez I, Hartman V, Hudej R, Strojnik A, Casar B. Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method. Med Phys 2013; 40: 011720. doi: 10.1118/1.4772075
- Vera-Sánchez JA, Ruiz-Morales C, González-Ló pez A. Monte Carlo uncertainty analysis of dose estimates in radiochromic film dosimetry with single-channel and multichannel algorithms. Phys Med 2018; 47: 23-33. doi: 10.1016/j.ejmp.2018.02.006
- Casar B, Gershkevitsh E, Mendez I, Jurković S, Huq MS. A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams. Med Phys 2019; 46: 944-63. doi: 10.1002/mp.13318
- Casar B, Gershkevitsh E, Mendez I, Jurković S, Saiful Huq M. Output correction factors for small static fields in megavoltage photon beams for seven ionization chambers in two orientations – perpendicular and parallel. Med Phys 2020; 47: 242-59. doi: 10.1002/mp.13894