Have a personal or library account? Click to login
Invisible Base Electrode Coordinates Approximation for Simultaneous SPECT and EEG Data Visualization Cover

Invisible Base Electrode Coordinates Approximation for Simultaneous SPECT and EEG Data Visualization

Open Access
|May 2014

References

  1. [1] McNally, K.A., Paige, A.L., Varghese, G., Zhang, H., Novotny, E.J., Spencer, S.S., Zubal, G., Blumenfeld, H. (2005). Localizing value of ictal-interictal SPECT analyzed by SPM (ISAS). Epilepsia, 46, 1450-1464.10.1111/j.1528-1167.2005.06705.x
  2. [2] O’Brien, T.J., So, E.L., Mullan, B.P., Hauser, M.F., Brinkmann, B.H., Bohnen, N.I., Hanson, D., Cascino, G.D., Jack, C.R. Jr, Sharbrough, F.W. (1998). Subtraction ictal SPECT coregistered to MRI improves clinical usefulness of SPECT in localizing the surgical seizure focus. Neurology, 50, 445-454.10.1212/WNL.50.2.445
  3. [3] Kowalczyk, L., Bajera, A., Goszczynska, H., Zalewska, E., Krolicki, L. (2013). Superposition of 3D EEG maps on SPECT images acquired from simultaneous examinations. Biocybernetics and Biomedical Engineering, 33, 196-203.10.1016/j.bbe.2013.09.002
  4. [4] Goszczyńska, H., Królicki, L., Bajera, A., Zalewska, E., Kowalczyk, L., Walerjan, P., Rysz, A., Kolebska, K. (2007). The procedure for SPECT and BEAM images adjustment. Polish Journal of Medical Physics and Engineering, 13, 115-125.10.2478/v10013-007-0010-9
  5. [5] Jasper, H.H. (1958). The ten-twenty electrode system of the International Federation. Electroencephalography and Clinical Neurophysiology, 10, 371-375.
  6. [6] Papademetris, X., Jackowski, M., Rajeevan, N., Constable, R.T., Staib, L.H. BioImageSuite: An integrated medical image analysis suite. Section of Bioimaging Sciences, Dept. of Diagnostic Radiology, Yale School of Medicine. http://www.bioimagesuite.org
  7. [7] Koessler, L., Cecchin, T., Caspary, O., Benhadid, A., Vespignani, H., Maillard, L. (2011). EEG-MRI coregistration and sensor labeling using a 3D laser scanner. Annals of Biomedical Engineering, 39, 983-995.10.1007/s10439-010-0230-0
  8. [8] Koessler, L., Maillard, L., Benhadid, A., Vignal, J.P., Braun, M., Vespignani, H. (2007). Spatial localisation of EEG electrodes. Clinical Neurophysiology, 37, 97-102.10.1016/j.neucli.2007.03.002
  9. [9] Oostenveld, R., Praamstra, P. (2001). The five percent electrode system for high-resolution EEG and ERP measurements. Clinical Neurophysiology, 112, 713-719.10.1016/S1388-2457(00)00527-7
  10. [10] Oostenveld, R., Praamstra, P., Stegeman, D.F., van Oosterom, A. (2001). Overlap of attention and movement-related activity in lateralized event-related brain potentials. Clinical Neurophysiology, 112, 477-484.10.1016/S1388-2457(01)00460-6
  11. [11] de Munck, J.C., van Houdt, P.J., Verdaasdonk, R.M., Ossenblok, P.W. (2012). A semi-automatic method to determine electrode positions and labels from gel artifacts in EEG/fMRI-studies. Neuroimage, 59, 399-403.10.1016/j.neuroimage.2011.07.02121784161
  12. [12] Rademacher, J., Caviness, V.S. Jr, Steinmetz, H., Galaburda, A.M. (1993). Topographical variation of the human primary cortices: Implications for neuroimaging, brain mapping, and neurobiology. Cerebral Cortex, 3 (4), 313-329.10.1093/cercor/3.4.3138400809
  13. [13] Scheinost, D., Teisseyre, T.Z., Distasio, M., DeSalvo, M.N., Papademetris, X., Blumenfeld, H. (2010). New open-source ictal SPECT analysis method implemented in BioImage Suite. Epilepsia, 51, 703-707.10.1111/j.1528-1167.2009.02425.x296362520074234
Language: English
Page range: 109 - 116
Submitted on: Jul 31, 2013
Accepted on: Apr 11, 2014
Published on: May 8, 2014
Published by: Slovak Academy of Sciences, Institute of Measurement Science
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2014 L. Kowalczyk, H. Goszczynska, E. Zalewska, A. Bajera, L. Krolicki, published by Slovak Academy of Sciences, Institute of Measurement Science
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.