Have a personal or library account? Click to login
Influence of Internal Gas Pipelines Built into the Structure on the Safety of Residents and Energy Eficiency Factors of the Building Cover

Influence of Internal Gas Pipelines Built into the Structure on the Safety of Residents and Energy Eficiency Factors of the Building

By: A. Romanovs,  J. Tihana and  N. Kondrahins  
Open Access
|Oct 2022

References

  1. 1. Prozuments, A., & Borodinecs, A. (2017). Indoor Air Stratification in Warm Air Supply Systems. ASHRAE J., 59, 54–65.
  2. 2. JSC GASO. (n.d.). Latvian Gas Distribution System Operator Statistics. Available at https://www.conexus.lv/latvias-gas-transmission-system
  3. 3. Borodinecs, A., Geikins, A., Barone, E., Jacnevs, V., & Prozuments, A. (2022). Solution of Bullet Proof Wooden Frame Construction Panel with a Built-In Air Duct. Buildings, 12. https://doi.org/10.3390/buildings12010030.10.3390/buildings12010030
  4. 4. Merilo, E.G., Groethe, M.A., Colton, J.D., & Chiba, S. (2010). Experimental Study of Hydrogen Release Accidents in a Vehicle Garage. Int. J. Hydrogen Energy, 36, 2136–2444. https://doi.org/10.1016/j.ijhydene.2010.04.056.10.1016/j.ijhydene.2010.04.056
  5. 5. Litto, R., Hayes, R.E., & Liu, B. (2006). Capturing Fugitive Methane Emissions from Natural Gas Compressor Buildings. J. Environ. Manage., 84, 347–361. https://doi.org/10.1016/j.jenvman.2006.06.007.10.1016/j.jenvman.2006.06.00716891053
  6. 6. Hajji, Y., Bouteraa, M., Elcafsi, A., Belghith, A., Bournot, P., & Kallel, F. (2015). Natural Ventilation of Hydrogen during a Leak in a Residential Garage. Renew. Sustain. Energy Rev., 50, 810–818. https://doi.org/10.1016/j.rser.2015.05.060.10.1016/j.rser.2015.05.060
  7. 7. Juwari, Handogo, R., Cahyono, T., Safarudin, M., Panca Anugraha, R., Aulia, F. … & Nuur Kharisma, M. (2020). Simulation of natural gas dispersion and explosion in vented enclosure using 3D CFD FLACS software. In: IOP Conference Series: Materials Science and Engineering (pp. 1–12). 16–17 September 2020, Chennai, India, Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/778/1/012144.10.1088/1757-899X/778/1/012144
  8. 8. Prozuments, A., Borodinecs, A., Zemitis, J., & Strelets, K.I. (2020). The Effect of the Air Duct Tightness on the Stability of the Indoor Air Parameters. Mag. Civ. Eng., 97. https://doi.org/10.18720/MCE.97.10.
  9. 9. Zajecs, D., Lebedeva, K., & Odineca, T. (2022). Application Possibilities of the Off-Grid Hvac System Operation Solution for Temporary Shelters in the Latvian Climate Conditions. Latv. J. Phys. Tech. Sci,. 59, 55–63.10.2478/lpts-2022-0011
  10. 10. Platais, I. (2008). Gas Supply. Part 2. pp. 1–219. Riga: RTU Publishing House (in Latvian).
  11. 11. Ionin, A. (1989). Gas Supply. M.: Moscow Building Press.
  12. 12. Cabinet of Ministers. (2014). General Construction Regulations. Latvijas Vestnesis. Available at https://likumi.lv/ta/en/en/id/269069
  13. 13. Cabinet of Ministers. (2014). Building Regulations. Latvijas Vestnesis. Available at https://likumi.lv/ta/id/269164-ekubuvnoteikumi
  14. 14. Cabinet of Ministers. (2015). Regulations Regarding the Latvian Building Code LBN 242-15 “Natural Gas External Gas Pipeline System”. Latvijas Vestnesis. Available at https://likumi.lv/ta/id/275017-noteikumipar-latvijas-buvnormativu-lbn-242-15-dabasgazes-arejo-gazesvadu-sistema
  15. 15. Cabinet of Ministers. (2015). Regulations Regarding Latvian Construction Standard LBN 241-15 “Internal Natural Gas Installation Pipework”. Latvijas Vestnesis. Available at https://likumi.lv/ta/en/en/id/275009
  16. 16. Latvian National Code EN 417:2015 Design of External Natural Gas Pipeline Systems with Presure 1,6 Mpa (16 Bar).
  17. 17. Latvian National Code EN 419 Internal Gas Pipelines. Installation.
  18. 18. Romanovs, A., Tihana, J., & Borodinecs, A. (2019). Impact of hidden defects on the durability and reliability of gas pipelines in cities. In: IOP Conference Series: Earth and Environmental Science (pp. 1–12). 27 May– 6 June 2019, Moscow, Institute of Physics Publishing. https://doi.org/10.1088/1755-1315/297/1/012046.10.1088/1755-1315/297/1/012046
  19. 19. Latvian National Code No. 445-1:2011. Operation and Maintenance of Natural Gas Distribution and Consumer Supply Systems with Max Operation Pressure 1,6 Mpa (16 Bar). Part 1: General Requirements.
  20. 20. Latvian National Code No. 445-2:2011. Operation and Maintenance of Natural Gas Distribution and Consumer Supply Systems with Max Operation Pressure 1,6 Mpa (16 Bar). Part 2: Maintenance Terms, Kinds of Work and the Execution Organization.
  21. 21. Selickis, A. (2018). Relocation of the Natural Gas Inlets in Apartment Buildings. Enerģija un Pasaule, 5 (112), 48–52.
DOI: https://doi.org/10.2478/lpts-2022-0039 | Journal eISSN: 2255-8896 | Journal ISSN: 0868-8257
Language: English
Page range: 33 - 45
Published on: Oct 13, 2022
Published by: Institute of Physical Energetics
In partnership with: Paradigm Publishing Services
Publication frequency: 6 issues per year

© 2022 A. Romanovs, J. Tihana, N. Kondrahins, published by Institute of Physical Energetics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.