Degradation of Cr3C2-NiCr coating prepared by the HVOF technique Cover

Degradation of Cr3C2-NiCr coating prepared by the HVOF technique

By:   
Open Access
|Sep 2013

Abstract

After a few hours of operation, a Cr3C2-NiCr-based HVOF coating on a spindle made of high-chromium steel X22Cr-MoV12-1 degraded when exposed to overheated steam. The study evaluates the level of coating damage by analysing chemical and phase composition on the surface and on the cross-section of the layer. Ni-Cr, Cr3C2 and Cr2O3 phases were detected in both degraded and non-degraded layers. During the exposure, the layer thickness thinned by an order of magnitude. The layer degradation was probably induced by oxidation in a steam environment; voluminous particles on the steel/coating interface might have played a negative role.

DOI: https://doi.org/10.2478/kom-2013-0009 | Journal eISSN: 1804-1213 | Journal ISSN: 0452-599X
Language: English, Czech
Page range: 82 - 86
Published on: Sep 19, 2013
Published by: Association of Czech and Slovak Corrosion Engineers
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2013 J. Rapouch, published by Association of Czech and Slovak Corrosion Engineers