Hybrid QuEChERS–micro-scale solid-phase extraction for LC-MS/MS determination of chloramphenicol in milk and muscle Cover

Hybrid QuEChERS–micro-scale solid-phase extraction for LC-MS/MS determination of chloramphenicol in milk and muscle

Open Access
|Oct 2026

Figures & Tables

Fig. 1.

Multiple-reaction monitoring LC-MS/MS chromatograms of blank (A) and fortified milk samples (B) at the level of 0.15 µg kg−1. The navy blue trace (the trace peaking directly below the given value 3.92 min) corresponds to chloramphenicol (CAP), while the pink trace (the trace extending higher) corresponds to the internal standard (CAP-D5 at the level of 1.5 µg kg−1)

Fig. 2.

Multiple-reaction monitoring LC-MS/MS chromatograms of blank (A) and fortified muscle samples (B) at the level of 0.15 µg kg−1. The navy blue trace (the trace peaking directly below the given value 3.92 min) corresponds to chloramphenicol (CAP), while the pink trace (the trace extending higher) corresponds to the internal standard (CAP-D5 at the level of 1.5 µg kg−1)

Table 1.

Validation results for chloramphenicol determination in milk and muscle matrices

ParameterMatrix0.10 µg kg−10.15 µg kg−10.30 µg kg−1
RSDr (%)*Milk7.56.85.6
RSDwR (%)*Milk8.98.16.7
Apparent recovery (%)Milk99.297.5101.8
Expanded uncertainty (µg kg−1, k = 2)Milk0.0210.0270.035
CCα (µg kg−1)*Milk0.10--
CCβ (µg kg−1)*Milk0.12--
RSDr (%)*Muscle8.27.46.1
RSDwR (%)*Muscle9.88.77.2
Apparent recovery (%)Muscle97.898.5101.2
Expanded uncertainty (µg kg−1, k = 2)Muscle0.0280.0350.042
CCα (µg kg−1)*Muscle0.10--
CCβ (µg kg−1)*Muscle0.12--

* RSDr – repeatability relative standard deviation; RSDwR – within-laboratory reproducibility relative standard deviation; CCα – decision limit; CCβ – detection capability; k = 2 – coverage factor used for estimation of expanded measurement uncertainty

Table 2.

Effect of membrane type on micro-scale solid-phase extraction clean-up performance

MembraneQualitative observationsImpact on method performance
PVDFStable flow, reproducible elution, no apparent analyte lossConsistent analytical response and good reproducibility
NylonInconsistent flow and partial analyte retentionIncreased variability and reduced reproducibility
PTFEPoor elution efficiency and unstable behaviour during centrifugationReduced robustness and potential analyte loss

[i] PVDF – polyvinylidene fluoride; PTFE – polytetrafluoroethylene

Table 3.

Robustness evaluation of selected micro-scale solid-phase extraction parameters

ParameterTested rangeEffect on analytical performance
Loading solvent (MeOH %)25–35%No significant effect observed
Elution solvent (MeOH %)60–70%Minor effect on analytical response
Elution volume0.18–0.22 mLNo significant effect on quantification
Reconstitution volume0.30–0.40 mLStable analytical response
Mixing time5–15 minNo significant differences observed
Membrane typePVDF / Nylon / PTFEPVDF provided the most stable performance

[i] PVDF – polyvinylidene fluoride; PTFE – polytetrafluoroethylene

Fig. 3.

Distribution of matrix effect values obtained for milk and muscle samples following the hybrid QuEChERS–micro-scale solid-phase extraction procedure. Dots show results for one blank sample each, boxes indicate the interquartile range, horizontal lines represent the median, and whiskers indicate the range of observed values

Table 4.

Comparison of selected LC-MS/MS methods for chloramphenicol determination in milk and muscle matrices

ReferenceMatrixExtraction / Clean-up strategyAnalytical performanceMain characteristics
14Bovine milkSPE (C18) + alumina clean-upRecovery ~90%, RSD 2.8 –4.3%, CCβ 0.03 µg/kgSPE and alumina-based clean-up workflow
10Multiple food and biological matricesACN extraction + chloroform clean-upRSD < 25%, CCβ 0.03 –0.04 µg/kgMulti-matrix LC-MS/MS workflow
13Liquid milk, milk powder, bovine muscleEthyl acetate extraction with additional clean-upAccuracy 89–107%, RSD 4–15%Simultaneous CAP and florfenicol determination
12Multiple food matrices including milk and muscleQuEChERSRecovery 86–111%, RSDr < 11.2%Simplified QuEChERS workflow
Milk and muscleQuEChERS + PVDF-MSPE microspin clean-upRecovery 97.5–101.8%, RSDr < 10%Additional microspin clean-up and matrix effect control
DOI: https://doi.org/10.2478/jvetres-2026-0055 | Journal eISSN: 2450-8608 (formerly 2300-3235)
Language: English
Submitted on: May 11, 2026
Accepted on: Oct 7, 2026
Published on: Oct 16, 2026
Published by: National Veterinary Research Institute in Pulawy
In partnership with: Paradigm Publishing Services

© 2026 Tomasz Śniegocki, Elżbieta Samorek, Weronika Krajewska, published by National Veterinary Research Institute in Pulawy
This work is licensed under the Creative Commons Attribution 4.0 License.