References
- Y. Zou and Z. Guo, "A review of electrical impedance techniques for breast cancer detection," Med. Eng. Phys., vol. 25, no. 2, pp. 79–90, Mar. 2003. https://doi.org/10.1016/S1350-4533(02)00194-7
- S. Kun, B. Ristic, R. a Peura, and R. M. Dunn, "Real-time extraction of tissue impedance model parameters for electrical impedance spectrometer," Med. Biol. Eng. Comput., vol. 37, no. 4, pp. 428–432, Jul. 1999. https://doi.org/10.1007/BF02513325
- A. S. Elwakil and B. Maundy, "Extracting the Cole-Cole impedance model parameters without direct impedance measurement," Electron. Lett., vol. 46, no. 20, p. 1367, 2010. https://doi.org/10.1049/el.2010.1924
- R. P. Braun, J. Mangana, S. Goldinger, L. French, R. Dummer, and A. A. Marghoob, "Electrical Impedance Spectroscopy in Skin Cancer Diagnosis," Dermatol. Clin., vol. 35, no. 4, pp. 489–493, Oct. 2017. https://doi.org/10.1016/j.det.2017.06.009
- R. J. Halter, A. Hartov, K. D. Paulsen, A. Schned, and J. Heaney, "Genetic and least squares algorithms for estimating spectral EIS parameters of prostatic tissues," Physiol. Meas., vol. 29, no. 6, pp. S111–S123, Jun. 2008. https://doi.org/10.1088/0967-3334/29/6/S10
- J. Hilland, "Simple sensor system for measuring the dielectric properties of saline solutions," Meas. Sci. Technol., vol. 8, no. 8, pp. 901–910, Aug. 1997. https://doi.org/10.1088/0957-0233/8/8/011
- E. T. McAdams, J. Jossinet, A. Lackermeier, and F. Risacher, "Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography," Med. Biol. Eng. Comput., vol. 34, no. 6, pp. 397–408, Nov. 1996. https://doi.org/10.1007/BF02523842
- H. Scharfetter, P. Hartinger, H. Hinghofer-Szalkay, and H. Hutten, "A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy," Physiol. Meas., vol. 19, no. 2, p. 012, May 1998.
- D. Miklavcic, N. Pavselj, and F. X. Hart, "Electric properties of tissues," Wiley Encycl. Biomed. Eng., vol. 209, pp. 1–12, 2006. https://doi.org/10.1002/9780471740360.ebs0403
- D. Ayllón, R. Gil-Pita, and F. Seoane, "Detection and Classification of Measurement Errors in Bioimpedance Spectroscopy," PLoS One, vol. 11, no. 6, p. e0156522, Jun. 2016. https://doi.org/10.1371/journal.pone.0156522
- K. Hollaus, O. Bíró, C. Gerstenberger, K. Preis, R. Stollberger, and B. Wagner, "Effect of stray capacitances on bio-impedances in quasi-static electric field," IEEE Transactions on Magnetics, 2005, vol. 41, no. 5, pp. 1940–1943. https://doi.org/10.1109/TMAG.2005.846218
- S. Grimnes and Ø. G. Martinsen, Bioimpedance and Bioelectricity Basics, 2nd ed. Elsevier, 2008.
- C. Grosse, "A program for the fitting of Debye, Cole–Cole, Cole–Davidson, and Havriliak–Negami dispersions to dielectric data," J. Colloid Interface Sci., vol. 419, pp. 102–106, Apr. 2014. https://doi.org/10.1016/j.jcis.2013.12.031
- A. Paterno, L. H. Negri, and P. Bertemes-filho, "Efficient Computational Techniques in Bioimpedance Spectroscopy," Appl. Biol. Eng. - Princ. Pract., no. July, pp. 3–27, 2012.
- R. Hassan, B. Cohanim, O. de Weck, and G. Venter, "A Comparison of Particle Swarm Optimization and the Genetic Algorithm," in 46th AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics and Materials Conference, 2005, pp. 1–13. https://doi.org/10.2514/6.2005-1897
- S. Gholami-Boroujeny and M. Bolic, "Extraction of Cole parameters from the electrical bioimpedance spectrum using stochastic optimization algorithms," Med. Biol. Eng. Comput., vol. 54, no. 4, pp. 643–651, 2016. https://doi.org/10.1007/s11517-015-1355-y
- T. Said and V. V. Varadan, "Variation of Cole-Cole model parameters with the complex permittivity of biological tissues," in 2009 IEEE MTT-S International Microwave Symposium Digest, 2009, pp. 1445–1448. https://doi.org/10.1109/MWSYM.2009.5165979
- A. Pinto, P. Bertemes-Filho, and A. S. Paterno, "Gelatin as a skin phantom for bioimpedance spectroscopy," IFMBE Proc., vol. 49, no. 3, pp. 178–182, 2015. https://doi.org/10.1007/978-3-319-13117-7_47
- P. Lai, X. Xu, and L. V. Wang, "Dependence of optical scattering from Intralipid in gelatin-gel based tissue-mimicking phantoms on mixing temperature and time," J. Biomed. Opt., vol. 19, no. 3, p. 035002, 2014. https://doi.org/10.1117/1.JBO.19.3.035002
- M. Kavitha and M. R. Reddy, "Characterization of tissue mimicking phantoms for acoustic radiation force impulse imaging," IST 2012 - 2012 IEEE Int. Conf. Imaging Syst. Tech. Proc., pp. 553–557, 2012. https://doi.org/10.1109/IST.2012.6295585
- M. D. Parker, M. Azhar, T. P. Babarenda Gamage, D. Alvares, A. J. Taberner, and P. M. F. Nielsen, "Surface deformation tracking of a silicone gel skin phantom in response to normal indentation," Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. EMBS, pp. 527–530, 2012. https://doi.org/10.1109/EMBC.2012.6345984
- M. P. Robinson, M. J. Richardson, J. L. Green, and A. W. Preece, "New materials for dielectric simulation of tissues," Phys. Med. Biol., vol. 36, no. 12, pp. 1565–1571, 1991. https://doi.org/10.1088/0031-9155/36/12/002
- C. Marchal, M. Nadi, a J. Tosser, C. Roussey, and M. L. Gaulard, "Dielectric properties of gelatine phantoms used for simulations of biological tissues between 10 and 50 MHz," Int. J. Hyperth., vol. 5, no. 6, pp. 725–732, Jan. 1989. https://doi.org/10.3109/02656738909140497
- K. S. Cole, "Permeability and impermeability of cell membranes for ions," Cold Spring Harb. Symp. Quant. Biol., vol. 8, no. 0, pp. 110–122, Jan. 1940. https://doi.org/10.1101/SQB.1940.008.01.013
- D. D. Macdonald, "Reflections on the history of electrochemical impedance spectroscopy," Electrochim. Acta, vol. 51, no. 8–9, pp. 1376–1388, Jan. 2006. https://doi.org/10.1016/j.electacta.2005.02.107
- J. G. Powles, "Cole-Cole plots as they should be," J. Mol. Liq., vol. 56, no. C, pp. 35–47, Jul. 1993. https://doi.org/10.1016/0167-7322(93)80017-P
- L. H. Negri, P. Bertemes-Filho, and A. S. Paterno, "Computational Intelligence Algorithms for Bioimpedance-Based Classification of Biological Material," in IFMBE Proceedings, vol. 37, 2011, pp. 1229–1232. https://doi.org/10.1007/978-3-642-23508-5_318
- B. A. Walther, J. L. Moore, and C. Rahbek, "The concepts of bias, precision and accuracy, and their use in testing the performance of species richness estimators, with a literature review of estimator performance," Ecography, vol. 28, no. 6, pp. 815–829, 2014. https://doi.org/10.1111/j.2005.0906-7590.04112.x
- H. Kwon et al., "Bioimpedance spectroscopy tensor probe for anisotropic measurements," Electron. Lett., vol. 48, no. 20, 2012. https://doi.org/10.1049/el.2012.2661
- C. Kim, A. Garcia-Uribe, S.-R. Kothapalli, and L. V. Wang, "Optical phantoms for ultrasound-modulated optical tomography," in Proceedings of SPIE, 2008, p. 68700M. https://doi.org/10.1117/12.766773
- L. H. Negri, H. J. Kalinowski, and A. S. Paterno, "Benchmark for standard and computationally intelligent peak detection algorithms for fiber Bragg grating sensors," in SPIE Proceedings, 2011, vol. 7753, p. 77537F. https://doi.org/10.1117/12.885964
- F. Seoane, R. Buendía, and R. Gil-Pita, "Cole parameter estimation from electrical bioconductance spectroscopy measurements," in 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC'10, 2010, pp. 3495–3498. https://doi.org/10.1109/IEMBS.2010.5627790
- A. O. Ragheb, L. A. Geddes, J. D. Bourland, and W. A. Tacker, "Tetrapolar electrode system for measuring physiological events by impedance," Med. Biol. Eng. Comput., vol. 30, no. 1, pp. 115–117, 1992. https://doi.org/10.1007/BF02446203
- T. J. Freeborn, T. Crenshaw, and S. Critcher, "Hook artifact correction of localized electrical bioimpedance for improved agreement between different device measurements," Biomed. Phys. Eng. Express, vol. 4, no. 1, p. 015016, Dec. 2017. https://doi.org/10.1088/2057-1976/aa971b
- J. P. Reilly, "Applied Bioelectricity: From Electrical Stimulation to Electropathology," in Applied Bioelectricity, 1998, pp. 1–11.
- R. Buendia, F. Seoane, and R. Gil-Pita, "A novel approach for removing the hook effect artefact from Electrical Bioimpedance spectroscopy measurements," in Journal of Physics: Conference Series, 2010, vol. 224, no. 1. https://doi.org/10.1088/1742-6596/224/1/012126
- H. Kalvøy, C. Aliau-Bonet, R. Pallas-Areny, and Ø. G. Martinsen, "Effects of stray capacitance to ground in three electrode monopolar needle bioimpedance measurements," in Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2015. https://doi.org/10.1109/EMBC.2015.7320137
- L. C. Ward, T. Essex, and B. H. Cornish, "Determination of Cole parameters in multiple frequency bioelectrical impedance analysis using only the measurement of impedances," Physiol. Meas., vol. 27, no. 9, pp. 839–850, Sep. 2006. https://doi.org/10.1088/0967-3334/27/9/007
- M. A. Kandadai, J. L. Raymond, and G. J. Shaw, "Comparison of electrical conductivities of various brain phantom gels: Developing a 'brain gel model,'" Mater. Sci. Eng. C, vol. 32, no. 8, pp. 2664–2667, Dec. 2012. https://doi.org/10.1016/j.msec.2012.07.024
- S. H. Oh et al., "Electrical conductivity images of biological tissue phantoms in MREIT," Physiol. Meas., vol. 26, no. 2, pp. S279–S288, 2005. https://doi.org/10.1088/0967-3334/26/2/026
- M. Guermazi, O. Kanoun, and N. Derbel, "Investigation of long time beef and veal meat behavior by bioimpedance spectroscopy for meat monitoring," IEEE Sens. J., vol. 14, no. 10, pp. 3624–3630, 2014. https://doi.org/10.1109/JSEN.2014.2328858
- J.-L. Damez, S. Clerjon, S. Abouelkaram, and J. Lepetit, "Dielectric behavior of beef meat in the 1–1500kHz range: Simulation with the Fricke/Cole–Cole model," Meat Sci., vol. 77, no. 4, pp. 512–519, Dec. 2007. https://doi.org/10.1016/j.meatsci.2007.04.028
- J. A. Gómez-Sánchez, W. Aristizábal-Botero, P. J. Barragán-Arango, and C. J. Felice, "Introduction of a muscular bidirectional electrical anisotropy index to quantify the structural modifications during aging in raw meat," Meas. Sci. Technol., vol. 20, no. 7, p. 075702, Jul. 2009. https://doi.org/10.1088/0957-0233/20/7/075702