Background

The aim of this study was to compare the dosimetry of carotid arteries (CAs) using three radiation therapy (RT) techniques, three-dimensional conformal RT (3D-CRT), helical tomotherapy-intensity-modulated RT (HT-IMRT), and volumetric modulated arc therapy (VMAT), in patients with early-stage glottic cancer.

Patients and Methods

A retrospective analysis of 28 patients was performed, and the right and left CAs were delineated. Mean and maximum dose (Dmax) values were compared across the three treatment techniques.

Results

The results indicate that 3D-CRT plans had the highest mean and maximum doses to CAs, while VMAT plans had the lowest doses.

Conclusions

Our study demonstrates the feasibility of sparing CAs with newer RT modalities. Further clinical studies are needed to determine if these techniques can reduce carotid stenosis-related events.

DOI: https://doi.org/10.2478/fco-2023-0009 | Journal eISSN: 1792-362X | Journal ISSN: 1792-345X
Language: English
Page range: 23 - 30
Submitted on: Jun 19, 2023
Accepted on: Oct 7, 2023
Published on: Nov 13, 2023
Published by: Helenic Society of Medical Oncology
In partnership with: Paradigm Publishing Services
Publication frequency: 2 issues per year

© 2023 B Pires, D Rothwell, I Guimarães, J Sousa, R Magalhães, T Serra, L Khouri, P Alves, published by Helenic Society of Medical Oncology
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.