Table 1:
The mechanical properties of the Profiber CW300
| Brand | Weight [g/m2] | Design thickness [mm] | Tensile strength [MPa] | Tensile E-modulus [GPa] | Elongation at break [%] |
|---|---|---|---|---|---|
| DCP PROFIBER CW300 | 300 | 0.166 | 4800 | 230 | 1.7 |

Figure 1:
Geometry of the non-prismatic test specimen of columns

Figure 2:
Fabrication of the specimens

Figure 3:
Performing specimens test to axial loading

Figure 4:
Instrumentation arrangement of the lateral loading

Figure 5:
Layout of the testing rig

Figure 6:
Rehabilitation using ferrocement jacketing

Figure 7:
Rehabilitation using steel jacketing
Table 2:
The performance levels according to ACI-374-2R-13 in terms of the drift ratio
| Drift status | Performance level | |||
|---|---|---|---|---|
| OP operational | IO immediate occupancy | LS life safety | CP collapse prevention | |
| Transient drift (temporary) | <<1% | ≤1% | ≤2% | ≤4% |
| Permanent drift (residual) | <<1% | <1% | ≤1% | ≤4% |

Figure 8:
Cyclic loading history
Table 3:
Protocol imposed on specimens (FJLA20 & SJLA20) in terms of performance level
| Cycle No. | Amplitude | Displacement [mm] | Drift ratio [%] | Transient performance level |
|---|---|---|---|---|
| 1 | 0.5Δy | 3.7 | 0.27 | IO |
| 2 | Δy | 7.4 | 0.54 | IO |
| 3 | 2Δy | 14.8 | 1.09 | LS |
| 4 | 3Δy | 22.2 | 1.64 | LS |
| 5 | 4Δy | 29.6 | 2.19 | CP |
| 6 | 5Δy | 37.0 | 2.74 | CP |
| 7 | 6Δy | 44.4 | 3.28 | CP |
Table 4:
Protocol imposed on specimens (FJLA40 & SJLA40) in terms of performance level
| Cycle No. | Amplitude | Displacement [mm] | Drift ratio [%] | Transient performance level |
|---|---|---|---|---|
| 1 | 0.5Δy | 2.9 | 0.21 | IO |
| 2 | Δy | 5.7 | 0.43 | IO |
| 3 | 2Δy | 11.4 | 0.84 | IO |
| 4 | 3Δy | 17.1 | 1.26 | LS |
| 5 | 4Δy | 22.8 | 1.68 | LS |
| 6 | 5Δy | 28.5 | 2.11 | CP |
| 7 | 6Δy | 34.2 | 2.53 | CP |
Table 5:
Axial load test results for non-prismatic RC columns
| Description | NPRIS-0 | NPRIS-1 | Average |
|---|---|---|---|
| Max. load [kN] | 854.4 | 955.8 | 905.1 |
| Axial displ. at max load [mm] | 3.036 | 3.86 | 3.448 |
| Strain in the rebar at max load | −0.0027 | −0.0028 | −0.00275 |
| Strain in the stirrup at max load | 0.0014 | 0.0015 | 0.00145 |
| Axial stiffness [kN/m] | 312,100 | 349,649 | 330,874 |
| Toughness [J] | 1047.5 | 1577 | 1312 |

Figure 9:
Shear failure mode in non-prismatic specimens

Figure 10:
Axial load – deflection curves for NPRIS-0 & NPRIS-1
Table 6:
Pushover test results (yield and ductility parameters)
| Specimen | Axial load | Δy [mm] | Py [kN] | Δu [mm] | μd = Δu/Δy |
|---|---|---|---|---|---|
| LA20 | 20% (181 kN) | 7.35 | 17.2 | 62.6 | 8.52 |
| LA40 | 40% (362 kN) | 5.70 | 32.0 | 27.43 | 4.80 |

Figure 11:
Pushover behaviour under 20% & 40% axial load

Figure 12:
Cracking pattern in the specimens LA20 & LA40 after pushover test
Table 7:
Dissipated energy prior to the rehabilitation (kN·mm)
| Specimen | Cycle 1 [0.5Δy] | Cycle 2 (0.5Δy) | Cycle 3 (Δy) | Cycle 4 (Δy) | Total |
|---|---|---|---|---|---|
| FJLA20 | 62.12 | 45.66 | 145.28 | 108.51 | 361.57 |
| SJLA20 | 38.72 | 30.88 | 131.53 | 100.65 | 301.78 |
| FJLA40 | 37.14 | 23.43 | 127.28 | 82.71 | 270.56 |
| SJLA40 | 35.43 | 25.46 | 131.38 | 63.67 | 255.94 |

Figure 13:
Displacement protocol imposed on test specimens before rehabilitation

Figure 14:
Cyclic behaviour of FJLA20 specimen under 181kN axial load

Figure 15:
Cyclic behaviour of SJLA20 specimen under 181kN axial load

Figure 16:
Cyclic behaviour of FJLA40 specimen under 362kN axial load

Figure 17:
Cyclic behaviour of SJLA40 specimen under 362kN axial load

Figure 18:
Pre rehabilitation dissipated energy
Table 8:
Cumulative dissipated energy after rehabilitation (kN.mm)
| Axial load ratio | Ferrocement jacket | Steel-plate jacket | Difference (ferrocement vs. steel) |
|---|---|---|---|
| 20% | 8,927.8 | 8,188.2 | +9.0% |
| 40% | 8,084.6 | 8,034.8 | +0.6% |
Table 9:
Residual deformation and resulting performance-level classification
| Specimen | Permanent deformation at final cycle [mm] | Performance level |
|---|---|---|
| FJLA20 | 21.14 | Collapse prevention (CP) |
| FJLA40 | 19.88 | Collapse prevention (CP) |
| SJLA20 | 10.41 | Life safety (LS) |
| SJLA40 | 12.79 | Collapse prevention CP (close to Life safety boundary) |

Figure 19:
Hysteresis loops for FJLA20 after the rehabilitation

Figure 20:
Hysteresis loops for SJLA20 after the rehabilitation

Figure 21:
Hysteresis loops for FJLA40 after the rehabilitation

Figure 22:
Hysteresis loops for SJLA40 after the rehabilitation

Figure 23:
Comparison among pushover, damaged induction, and post rehabilitation response