
Figure 1:
Dog-bone specimens of SC-ECC mixtures under direct tensile test: (a) specimen mounted in the testing machine during loading, and (b) specimen after failure showing the final dominant crack and residual fine cracks within the gauge length

Figure 2:
The experimental program of flowchart summarizing sequence for SC-ECC mixtures, including material selection, specimen casting, curing regime, exposure conditions, and testing schedule. The chart outlines the chronological stages—from material preparation

Figure 3:
Compressive strength testing of SC-ECC specimens: (a) specimens after long-term exposure before testing, (b) experimental setup during compressive loading, and (c) post-failure appearance exhibiting gradual crushing and limited fragmentation, indicative

Figure 4:
Water permeability test setup for SC-ECC specimens under 0.5 MPa hydrostatic pressure, results evaluated according to DIN 1048-5 (1991)
Table 1:
Chloride penetration classification based on total charge passed. ASTM C1202 (2022)
| Total charge passed (Coulombs) | Chloride penetration classification |
|---|---|
| <4000 | High |
| 2000–4000 | Moderate |
| 1000–2000 | Low |
| 100–1000 | Very low |
| >100 | Negligible penetration |

Figure 5:
Rapid chloride penetration testing of SC-ECC specimens: (a) specimen preparation and surface sealing of 100 × 50 [mm] cylindrical discs before testing, and (b) data acquisition and monitoring of the total charge passed through the specimens

Figure 6:
Half-cell potential testing of SC-ECC specimens: (a) typical test setup showing electrode positioning and electrical connection on the specimen surface, and (b) measurement of corrosion potential using a Cu/CuSO4 reference electrode (CSE)

Figure 7:
Relative compressive strength development of SC-ECC specimens under chloride-only, and combined chloride–sulphate exposure at 28, 90, 180, and 270 days (normalised to 28-day values = 100 %)

Figure 8:
Water penetration depth of SC-ECC specimens exposed to different sulphate concentrations (2.5 %, 5.0 %, and 7.5 % Na2SO4) at 28, 180, and 270 days under partial-immersion conditions. Each value represents the mean of three specimens

Figure 9:
Rapid chloride penetration (RCPT) results of SC-ECC specimens under different sulphate concentrations (2.5–7.5 % Na2SO4) at 56 days. Each value represents the mean of three specimens. The dashed line denotes the ASTM C1202 limit for “very low” chloride Penetration (1000 C)
Table 2:
Half-cell potential results of SC-ECC specimens under different exposure regimes (values in mV vs. CSE; ASTM C876 classification shown in parentheses)
| Exposure Condition | 28 days mean (mV) | Corrosion risk classification (ASTM C876) @28d | 90-day mean (mV) | Corrosion risk classification (ASTM C876) @90d | 180 days (mV) | Corrosion risk classification (ASTM C876) @180d | 270 days (mV) | Corrosion risk classification (ASTM C876) @270d |
|---|---|---|---|---|---|---|---|---|
| 7.5% Na2SO4 | −205 | Moderate | −217 | Moderate | −235 | Moderate | −252.5 | Moderate |
| 5% Na2SO4 | −184 | Low | −196 | Low | −210 | Low/Moderate | −222.5 | Moderate |
| 2.5% Na2SO4 | −170 | Low | −182 | Low | −195 | Low | −207.5 | Low/Moderate |
| 7.5% Na2SO4 + 3% NaCl | −340 | Moderate/High | −351 | Moderate/High | −395 | High | −430 | High/Very high |
| 5% Na2SO4 + 3% NaCl | −290 | Moderate | −305 | Moderate | −345 | Moderate/High | −375 | High |
| 2.5% Na2SO4 + 3% NaCl | −270 | Moderate | −285 | Moderate | −317.5 | Moderate | −345 | Moderate/High |
| 3% NaCl only | −230 | Moderate | −248 | Moderate | −277.5 | Moderate | −310 | Moderate (Near high) |
| Water (reference) | −118 | Very Low | −118 | Very Low | −122.5 | Low | −127.5 | Low |

Figure 10:
Development of half-cell potential of SC-ECC specimens under chloride-only, sulphate-only, and combined chloride–sulphate exposures up to 270 days. The dashed line at −350 mV denotes the ASTM C876 threshold for high corrosion probability

Figure 11:
SEM micrographs of SC-ECC specimens showing microstructural evolution with sulphate concentration and exposure duration: (a) 28-day water-cured reference sample; (b) 2.5 % Na2SO4 — early ettringite nucleation near fibre–matrix interfaces; (c) 5 % Na2SO4 - denser ettringite and gypsum deposits causing local cracking; (d) 7.5 % Na2SO4 — severe matrix deterioration and widened ITZ; (e) high-magnification view of fibre–matrix interphase highlighting partial debonding and secondary deposition
