Have a personal or library account? Click to login

Tilt-Strain Changes Linked to a Jacking System Test

Open Access
|Jun 2022

Abstract

A sector of the San Marco Hospital (Catania, Italy) was the subject of a jacking test in order to demonstrate the substitutability of the seismic isolator. A monitoring system, included tiltmeters and strain gauges, was applied to one column. Two distinct behaviours have been identified during the unloading stage, the first in which the column and the roof are still attached and a second in which the detachment takes place. The jacking system caused the column to return to its original position, induced by the building structure for thermoelastic causes.

DOI: https://doi.org/10.2478/cee-2022-0022 | Journal eISSN: 2199-6512 | Journal ISSN: 1336-5835
Language: English
Page range: 234 - 243
Published on: Jun 29, 2022
Published by: University of Žilina
In partnership with: Paradigm Publishing Services
Publication frequency: 2 times per year

© 2022 Salvatore Gambino, Giuseppe Falzone, Angelo Ferro, Giuseppe Laudani, Luciano Scuderi, published by University of Žilina
This work is licensed under the Creative Commons Attribution 4.0 License.