Have a personal or library account? Click to login
Testing of Regulating and Non-Regulating Hydraulic Pumps Cover

Abstract

This article deals with the testing of regulating and non-regulating hydraulic pumps in laboratory conditions. The laboratory test was carried out on the hydraulic device consisting of two separate hydraulic circuits (for testing the non-regulating hydraulic pump and regulating hydraulic pump). A throttle valve or proportional throttle valve is used for loading. During the laboratory tests, the flow efficiency of the non-regulating hydraulic pump at rotation speed n = 1,500 rpm (nominal speed) was ηpp = 98.91% (0 MPa) and ηpp = 94.97% (20 MPa), and for the regulating hydraulic pump, the values were ηpp = 97.57% (0 MPa) and ηpp = 94.54% (20 MPa). The determined values of flow efficiency of hydraulic pumps determine the correct operation of the experimental hydraulic laboratory equipment.

Language: English
Page range: 231 - 237
Published on: Nov 14, 2023
Published by: Slovak University of Agriculture in Nitra
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2023 Ján Kosiba, Gabriela Čurgaliová, Zdenko Tkáč, Juraj Jablonický, Liudmyla Hanushchak-Yefimenko, Tetiana Bukoros, published by Slovak University of Agriculture in Nitra
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.