References
- Mohamed RN, Basha S, Al-Thomali Y. Maxillary molar distalisation with miniscrew-supported appliances in Class II malocclusion: a systematic review. Angle Orthod 2018;88:494–502.
- Ali D, Mohammed H, Koo SH, Kang KH, Kim SC. Three-dimensional evaluation of tooth movement in Class II malocclusions treated without extraction by orthodontic mini-implant anchorage. Korean J Orthod 2016;46:280–9.
- Flores-Mir C, McGrath L, Heo G, Major PW. Efficiency of molar distalisation associated with second and third molar eruption stage. Angle Orthod 2013;83:735–42.
- Bellini-Pereira SA, Pupulim DC, Aliaga-Del Castillo A, Henriques JFC, Janson G. Time of maxillary molar distalisation with non-compliance intraoral distalizing appliances: a meta-analysis. Eur J Orthod 2019;41:652–60.
- Bussick TJ, McNamara JA Jr. Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofacial Orthop 2000;117:333–43.
- Ghosh J, Nanda RS. Evaluation of an intraoral maxillary molar distalisation technique. Am J Orthod Dentofacial Orthop 1996;110:639–46.
- Gelgör IE, Büyükyilmaz T, Karaman AI, Dolanmaz D, Kalayci A. Intraosseous screw-supported upper molar distalisation. Angle Orthod 2004;74:838–50.
- Flores-Mir C, McGrath LM, Heo G, Major PW. Efficiency of molar distalisation with the XBow appliance related to second molar eruption stage. Eur J Orthod 2013;35:745–51.
- Bechtold TE, Park YC, Kim KH, Jung H, Kang JY, Choi YJ. Long-term stability of miniscrew anchored maxillary molar distalisation in Class II treatment. Angle Orthod 2020;90:362–8.
- Hilgers JJ. The pendulum appliance for Class II non-compliance therapy. J Clin Orthod 1992;26:706–14.
- Bolla E, Muratore F, Carano A, Bowman SJ. Evaluation of maxillary molar distalisation with the distal jet: a comparison with other contemporary methods. Angle Orthod 2002;72:481–94.
- Kinzinger GS, Eren M, Diedrich PR. Treatment effects of intraoral appliances with conventional anchorage designs for non-compliance maxillary molar distalisation: a literature review. Eur J Orthod 2008;30:558–71.
- Keles A, Sayinsu K. A new approach in maxillary molar distalisation: intraoral bodily molar distalizer. Am J Orthod Dentofacial Orthop 2000;117:39–48.
- Han S, Bayome M, Lee J, Lee YJ, Song HH, Kook YA. Evaluation of palatal bone density in adults and adolescents for application of skeletal anchorage devices. Angle Orthod 2012;82:625–31.
- Choi YJ, Lee JS, Cha JY, Park YC. Total distalisation of the maxillary arch in a patient with skeletal Class II malocclusion. Am J Orthod Dentofacial Orthop 2011;139:823–33.
- Yoon JH, Cha JY, Choi YJ, Park WS, Han SS, Lee KJ. Simulation of miniscrew-root distance available for molar distalisation depending on the miniscrew insertion angle and vertical facial type. PLoS One 2020;15:e0239759.
- Sugawara J, Kanzaki R, Takahashi I, Nagasaka H, Nanda R. Distal movement of maxillary molars in nongrowing patients with the skeletal anchorage system. Am J Orthod Dentofacial Orthop 2006;129:723–33.
- Kang S, Lee SJ, Ahn SJ, Heo MS, Kim TW. Bone thickness of the palate for orthodontic mini-implant anchorage in adults. Am J Orthod Dentofacial Orthop 2007;131(4 Suppl):S74–S81.
- Chung KR, Choo H, Kim SH, Ngan P. Timely relocation of mini-implants for uninterrupted full-arch distalisation. Am J Orthod Dentofacial Orthop 2010;138:839–49.
- Kim HJ, Yun HS, Park HD, Kim DH, Park YC. Soft-tissue and cortical-bone thickness at orthodontic implant sites. Am J Orthod Dentofacial Orthop 2006;130:177–82.
- Yamada K, Kuroda S, Deguchi T, Takano-Yamamoto T, Yamashiro T. Distal movement of maxillary molars using miniscrew anchorage in the buccal interradicular region. Angle Orthod 2009;79:78–84.
- Cambiano AO, Janson G, Fuziy A, Garib DG, Lorenzoni DC. Changes consequent to maxillary molar distalisation with the bone-anchored pendulum appliance. J Orthod Sci 2017;6:141–6.
- Cassetta M, Brandetti G, Altieri F. Miniscrew-supported distal jet versus conventional distal jet appliance: A pilot study. J Clin Exp Dent 2019;11:e650–e8.
- Park CO, Sa’aed NL, Bayome M, Park JH, Kook Y-A, Park Y-S, et al. Comparison of treatment effects between the modified C-palatal plate and cervical pull headgear for total arch distalisation in adults. Korean J Orthod 2017;47:375–83.
- Fudalej P, Antoszewska J. Are orthodontic distalizers reinforced with the temporary skeletal anchorage devices effective? Am J Orthod Dentofacial Orthop 2011;139:722–9.
- Duran GS, Görgülü S, Dindaroğlu F. Three-dimensional analysis of tooth movements after palatal miniscrew-supported molar distalisation. Am J Orthod Dentofacial Orthop 2016;150:188–97.
- Jo SY, Bayome M, Park J, Lim HJ, Kook YA, Han SH. Comparison of treatment effects between four premolar extraction and total arch distalisation using the modified C-palatal plate. Korean J Orthod 2018;48:224–35.
- Kaya B, Sar C, Arman-Özçirpici A, Polat-Özsoy O. Palatal implant versus zygoma plate anchorage for distalisation of maxillary posterior teeth. Eur J Orthod 2013;35:507–14.
- Kook YA, Kim SH, Chung KR. A modified palatal anchorage plate for simple and efficient distalisation. J Clin Orthod 2010;44:719–30;quiz 43.
- Lee SK, Abbas NH, Bayome M, Baik UB, Kook YA, Hong M, et al. A comparison of treatment effects of total arch distalisation using modified C-palatal plate vs buccal miniscrews. Angle Orthod 2018;88:45–51.
- Nienkemper M, Wilmes B, Pauls A, Yamaguchi S, Ludwig B, Drescher D. Treatment efficiency of mini-implant-borne distalisation depending on age and second-molar eruption. J Orofac Orthop 2014;75:118–32.
- Kırcalı M, Yüksel AS. Evaluation of Dentoalveolar and Dentofacial Effects of a Mini-Screw-Anchored Pendulum Appliance in Maxillary Molar Distalisation. Turk J Orthod 2018;31:103–9.
- Suzuki EY, Suzuki B. Maxillary molar distalisation with the indirect Palatal miniscrew for Anchorage and Distalisation Appliance (iPANDA). Orthodontics (Chic) 2013;14:e228–e241.
- Miyawaki S, Koyama I, Inoue M, Mishima K, Sugahara T, Takano-Yamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 2003;124:373–8.
- Wiechmann D, Meyer U, Büchter A. Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study. Clin Oral Implants Res 2007;18:263–7.
- Gelgor IE, Karaman AI, Buyukyilmaz T. Comparison of 2 distalisation systems supported by intraosseous screws. Am J Orthod Dentofacial Orthop 2007;131:161; e1-8.
- Keles A. Unilateral distalisation of a maxillary molar with sliding mechanics: a case report. J Orthod 2002;29:97–100.
- Song B-J, Lee K-J, Cha J-Y, Lee J-S, Mo S-S, Yu H-S. Stability of the maxillary and mandibular total arch distalisation using temporary anchorage devices (TADs) in adults. Appl Sci 2022;12:2898.
- Crismani AG, Bertl MH, Celar AG, Bantleon HP, Burstone CJ. Miniscrews in orthodontic treatment: review and analysis of published clinical trials. Am J Orthod Dentofacial Orthop 2010;137:108–13.
- Kircelli BH, Pektaş ZO, Kircelli C. Maxillary molar distalisation with a bone-anchored pendulum appliance. Angle Orthod 2006;76:650–9.
- Ludwig B, Glasl B, Kinzinger GS, Walde KC, Lisson JA. The skeletal frog appliance for maxillary molar distalisation. J Clin Orthod 2011;45:77–84; quiz 91.
- Yu IJ, Kook YA, Sung SJ, Lee KJ, Chun YS, Mo SS. Comparison of tooth displacement between buccal mini-implants and palatal plate anchorage for molar distalisation: a finite element study. Eur J Orthod 2014;36:394–402.
- Reddy MS, Mayfield-Donahoo T, Vanderven FJ, Jeffcoat MK. A comparison of the diagnostic advantages of panoramic radiography and computed tomography scanning for placement of root form dental implants. Clin Oral Implants Res 1994;5:229–38.
- Gribel BF, Gribel MN, Frazäo DC, McNamara JA Jr., Manzi FR. Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans. Angle Orthod 2011;81:26–35.
- Antonarakis GS, Kiliaridis S. Maxillary molar distalisation with noncompliance intramaxillary appliances in Class II malocclusion. A systematic review. Angle Orthod 2008;78:1133–40.
- Polat-Ozsoy O, Kircelli BH, Arman-Ozçirpici A, Pektaş ZO, Uçkan S. Pendulum appliances with 2 anchorage designs: conventional anchorage vs bone anchorage. Am J Orthod Dentofacial Orthop 2008;133:339.e9–e17.
- Grec RH, Janson G, Branco NC, Moura-Grec PG, Patel MP, Castanha Henriques JF. Intraoral distalizer effects with conventional and skeletal anchorage: a meta-analysis. Am J Orthod Dentofacial Orthop 2013;143:602–15.