FIGURE 1.

Approximation of the characteristics of the TsK-135/8 compressor
Source: own work.
Approximation of the characteristics of the TsK-135/8 compressor Source: own work.

FIGURE 2.

Design scheme of the gas ejector
Source: own work.
Design scheme of the gas ejector Source: own work.

FIGURE 3.

Calculated characteristic of the ejector at M = 8.6 (1 – adiabatic characteristic, 2 – short-circuit mode in Section 3-3, 3 – critical mode limit in Section 3-3)
Source: own work.
Calculated characteristic of the ejector at M = 8.6 (1 – adiabatic characteristic, 2 – short-circuit mode in Section 3-3, 3 – critical mode limit in Section 3-3) Source: own work.

FIGURE 4.

Dependence of the flow compression ratio ε to the ejection coefficient u
Source: own work.
Dependence of the flow compression ratio ε to the ejection coefficient u Source: own work.

FIGURE 5.

Dynamics of pressure change in the SG at different ejector modules (1 – M = 7.0; 2 – M = 8.6; 3 – M = 11.0; 4 – compressor without ejector)
Source: own work.
Dynamics of pressure change in the SG at different ejector modules (1 – M = 7.0; 2 – M = 8.6; 3 – M = 11.0; 4 – compressor without ejector) Source: own work.

FIGURE 6.

Dependence of the time of filling of the ZO on the ejector module
Source: own work.
Dependence of the time of filling of the ZO on the ejector module Source: own work.

FIGURE 7.

Dependence of the filling time of the nozzle on the pressure before the nozzle
Source: own work.
Dependence of the filling time of the nozzle on the pressure before the nozzle Source: own work.

FIGURE 8.

Effect of additional resistance on the ejector characteristic: 1 – φ4 = 0.925 (standard settings), 2 – φ4 = 0.636 (filter at the input), 3 – critical mode limit in Section 3-3
Source: own work.
Effect of additional resistance on the ejector characteristic: 1 – φ4 = 0.925 (standard settings), 2 – φ4 = 0.636 (filter at the input), 3 – critical mode limit in Section 3-3 Source: own work.
DOI: https://doi.org/10.22630/srees.9956 | Journal eISSN: 2543-7496 | Journal ISSN: 1732-9353
Language: English
Page range: 401 - 418
Submitted on: Sep 10, 2024
Accepted on: Oct 17, 2024
Published on: Nov 19, 2024
Published by: Warsaw University of Life Sciences - SGGW Press
In partnership with: Paradigm Publishing Services

© 2024 Sergii Surkov, Volodymyr Kravchenko, Iryna Korduba, Andrii Golovchenko, Oleksandr Butenko, Serhii Tsybytovskyi, Yuliia Trach, published by Warsaw University of Life Sciences - SGGW Press
This work is licensed under the Creative Commons Attribution-NonCommercial 4.0 License.