A field analysis trial comparing the turnaround times of routine and STAT red blood cell immunohematology testing Cover

A field analysis trial comparing the turnaround times of routine and STAT red blood cell immunohematology testing

Paid access
|Oct 2019

Abstract

The turnaround time (TAT) for pre-transfusion testing is important for prompt clinical decision-making. TAT includes the time between the arrival of the sample and the initiation of testing, plus the processing time (PT) required to generate and report a result. The TAT in larger blood banks is mostly dependent upon the capability of the analyzer used. In smaller blood banks, where manual work is often performed, the TAT is dependent on availability and experience of staff, testing resources, and workload. Our site performed a comparative analysis of the ORTHO VISION® (Ortho Clinical Diagnostics, Raritan, NJ) and the Echo® (Immucor, Norcross, GA) blood bank analyzers, using the TAT and PT of standard blood bank tests as the outcome metrics. Tests were run in various combinations to reflect the standard workflow of a busy hospital transfusion service and under routine and immediate or STAT conditions. We also compared manual versus automated processing TATs for a variety of pre-transfusion tests and antibody titers. We found that the capacity of the VISION to load and run new samples, even while several other tests were ongoing, allowed for faster overall TAT when compared with samples run on the Echo. The PTs of the two analyzers (from load to result) were also compared, and we found them to be equivalent. These findings highlight the inherent flaw in considering only PT when assessing a laboratory’s ability to efficiently and consistently make results available to best meet customer and patient needs. In addition, we observed a tighter distribution of TATs and PTs when the VISION was compared with the Echo analyzer, providing a higher level of predictability for availability of results. Finally, when compared with manual antibody titer testing, the VISION analyzer showed a faster PT. Immunohematology2017;33:1–5.

DOI: https://doi.org/10.21307/immunohematology-2019-001 | Journal eISSN: 1930-3955 | Journal ISSN: 0894-203X
Language: English
Page range: 1 - 5
Published on: Oct 9, 2019
Published by: American National Red Cross
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2019 K. Sackett, A. Kjell, A.M. Schneider, C.S. Cohn, published by American National Red Cross
This work is licensed under the Creative Commons License.