Have a personal or library account? Click to login
Retrofitting the Structure of the Catalytic Cracking Reactor, from Petrobrazi Refinery, Ploieşti by Transforming the Steel Structure into a Moment Resisting Frame and Enhancing the Damping of the Structure by Means of Viscous Dampers Cover

Retrofitting the Structure of the Catalytic Cracking Reactor, from Petrobrazi Refinery, Ploieşti by Transforming the Steel Structure into a Moment Resisting Frame and Enhancing the Damping of the Structure by Means of Viscous Dampers

Open Access
|Jan 2016

Abstract

The present paper presents the structural and seismic retrofit solution for the structure of the Catalytic Cracking Reactor, from Petrobrazi Refinery, Ploiești, Romania. The spatial truss type steel structure was designed and built during 1965-1968, following United States codes of that time. The capacity of the reactor is intended to be increased, thus its weight increases by approx. 43%. The retrofit solution had to take into consideration many criteria, not only technical, but also technological. After analyzing several possibilities, it was decided that the only feasible solution in order to fulfill all these requirements was to significantly increase the viscous damping of the structure – by introducing viscous dampers in its diagonals, accompanied by the strengthening of steel structure and changing the structural system into a moment resisting frame.

Language: English
Page range: 33 - 49
Published on: Jan 22, 2016
Published by: Technical University of Civil Engineering of Bucharest
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2016 Ionuţ Vasilescu, Emil Tănase, Dragoş Marcu, published by Technical University of Civil Engineering of Bucharest