Have a personal or library account? Click to login
Seismic Design Of Low-Rise Office Buildings According To Romanian Seismic Codes. Case Study. Cover

Seismic Design Of Low-Rise Office Buildings According To Romanian Seismic Codes. Case Study.

Open Access
|Jul 2015

Abstract

The paper presents a study case and highlights the changes made by the new, in force, seismic Code P100-1/2013 in comparison with the former P100-1/2006, concerning the reinforced concrete frame structural systems design. Different seismic designed RC frames systems, compatible with modern office requirements, were studied. The influence of the earthquake codes provisions on design of regular buildings, having openings fitted for open spaces, with a story height of 3.50m, was assessed. The benefits of tubular structures, with rigid frames made of closely spaced columns on the building perimeter, were analyzed as well. The results of the study case are presented emphasizing the consequences of the application of the new seismic Code on the computation of the reinforced concrete frame structures.

Language: English
Page range: 10 - 18
Published on: Jul 10, 2015
Published by: Technical University of Civil Engineering of Bucharest
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2015 Ana-Maria Ghiţă, published by Technical University of Civil Engineering of Bucharest