Have a personal or library account? Click to login
Influence of Blood Sample Hemolysis on Hematological and Biochemical Parameters in Cows During Early Lactation Cover

Influence of Blood Sample Hemolysis on Hematological and Biochemical Parameters in Cows During Early Lactation

Open Access
|Dec 2016

References

  1. ANĐELIĆ T., LAZIĆ VASIĆ M., ĐURAŠINOVIĆ T.: Influence of hemolysis on biochemistry analysis. Medicinska revija, 5, 2, 183-185, 2013.
  2. BELIĆ B., CINCOVIĆ M., TOHOLJ B., STEVANČEVIĆ M., DELIĆ B.: Influence of blood samples haemolysis of dairy cows on blood biochemical parameters transported at stable temperature. Veterinarski žurnal R.Srpske. 14(2):217-223, 2014.
  3. BELIĆ B., CINCOVIĆ M.R., KOVAČEVIĆ Z., STOJANOVIĆ D., PLAVŠA N., SPASOJEVIĆ J., PETROVIĆ M.: Common preanalitycal errors in vacutainers with blood samplå obtained from cows. Zbornik 26. Savetovanja veterinara Srbije, 2015a
  4. BELIĆ B., CINCOVIĆ M.R., DOŠENOVIĆ M., STOJANOVIĆ D., KOVAČEVIĆ Z.: The effects of different anticoagulants on biochemical parameters in blood of dairy cows. Veterinarski glasnik, 69 (1-2): 13-20, 2015.
  5. BELIĆ B., CINCOVIĆ M.R., STEVANČEVIĆ M., TOHOLJ B., POPOVIĆ-VRANJEŠ A., PEJANOVIĆ R., DAVIDOV I., POTKONJAK A., STANČIĆ I.: Influence of metabolic profile in early lactation and welfare score of farm to milk production and service period in dairy cow. Contemporary agroculture, 64(1-2):65-71,2015.
  6. BRAUN JP., BOURGES ABELLA N., GEFRE A., CONCORDET D., TRUMEL C.: The preanalytic phase in veterinary clinical pathology. Vet Clin Pathol 44(1):8–25,2015.
  7. CINCOVIĆ M.R., HRISTOVSKA T., BELIĆ B., ĐOKOVIĆ R., KOVAČEVIĆ Z., PETROVIĆ M., DOŠENOVIĆ M., DELIĆ B.: Influence of niacin on lipid metabolism in dairy cows during early lactation. Contemporary agriculture, 64(1-2):72-77, 2015.
  8. ĐOKOVIĆ R., KURĆUBIĆ V., ILIĆ Z., CINCOVIČ M.R., PETROVIĆ M., DELIĆ B.: Serum activities of ast, alt, ggt and ldh in clinically healthy dairy cows during transitional period and mid lactation. Contemporary agriculture, 63(1-2): 106-111,2014.
  9. GRAFMEYER D, BONDON M, MANCHON M, LEVILLAIN P.: The influence of bilirubin, haemolysis and turbidity on 20 analytical tests performed on automatic analysers. Results of an interlaboratory study. Eur J Clin Chem Clin Biochem, 33, 31–52, 1995.10.1515/cclm.1995.33.1.317756439
  10. GUDER W.: Haemolysis as an influence and interference factor in clinical chemistry. J Clin Chem Clin Biochem, 24, 125–126, 1986.
  11. HUMANN-ZIEHANK E., GANTER M.: Pre-analytical factors affecting the results of laboratory blood analyses in farm animal veterinary diagnostics. Animal, 6(7):1115–1123, 2012.
  12. JAY D., PROVASEK D.: Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays. Clin Chem, 39, 1804–1810, 1993.10.1093/clinchem/39.9.1804
  13. KOSEOGLU M., HUR A., ATAJ A., CUHADAR S.: Effects of hemolysis interferences on routine biochemistry parameters. Biochemia Medica, 21(1):79–85, 2011.
  14. KOVAČEVIĆ Z., CINCOVIČ M.R., BELIĆ B., STOJANOVIĆ D., ĐOKOVIĆ R.: Relationship between hematological and matabolic parameters in cows during early lactation. Contemporary agriculture, 64(1-20):60-64, 2015.
  15. KROLL M.H., ELIN RJ.: Interference with clinical laboratory analyses. Clin Chem, 40, 1996–2005, 1994.10.1093/clinchem/40.11.1996
  16. LIPPI G., BLANCKAERT N., BONINI P., GREEN S., KITCHEN S., PALICKA V., VASSAULT A.J., PLEBANI M.: Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories. Clin Chem Lab Med, 46, 6, 764–772, 2008.10.1515/CCLM.2008.17018601596
  17. LIPPI G., SALVAGNO G.L., MONTAGNANA M., BROCCO G., GUIDI G.C.: Influence of hemolysis on routine clinical chemistry testing. Clin Chem Lab Med, 44, 311–316, 2006.10.1515/CCLM.2006.05416519604
  18. SONNTAG O.: Haemolysis as an interference factor in clinical chemistry. J Clin Chem Clin Biochem, 24, 127–139. 1986.
  19. STEEN G., VERMEER H.J., NAUS A.J., GOEVAERTS B., AGRICOLA P.T., SCHOENMAKERS CH.: Multicenter evaluation of the interference of hemoglobin, bilirubin and lipids on Synchron LX-20 assays. Clin Chem Lab Med, 44, 413–419, 2006.10.1515/CCLM.2006.06716599834
DOI: https://doi.org/10.1515/contagri-2016-0016 | Journal eISSN: 2466-4774 | Journal ISSN: 0350-1205
Language: English
Page range: 39 - 43
Submitted on: Oct 16, 2016
Accepted on: Nov 18, 2016
Published on: Dec 30, 2016
Published by: University of Novi Sad
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2016 Marko R. Cincović, Jože Starič, Branislava Belić, Jožica Ježek, Ivana Lakić, published by University of Novi Sad
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.