Have a personal or library account? Click to login
The feasibility of using compression bioimpedance measurements to quantify peripheral edema Cover

The feasibility of using compression bioimpedance measurements to quantify peripheral edema

Open Access
|Dec 2014

References

  1. Di Somma S, De Berardinis B, Bongiovanni C, Marino R, Ferri E, Alfei B. Use of BNP and Bioimpedance to Drive Therapy in Heart Failure Patients. Congestive Heart Failure. 2010; 16 (Suppl 1): S56-61. http://dx.doi.org/10.1111/j.1751-7133.2010.00162.x10.1111/j.1751-7133.2010.00162.x
  2. McDonald K. Monitoring fluid status at the outpatient level: the need for more precision. Congestive Heart Failure. 2010; 16(4) (Suppl 1): S52–S55. http://dx.doi.org/10.1111/j.1751-7133.2010.00171.x
  3. Pirlich M, Schütz T, Ockenga J, Biering H, Gerl H, Schmidt et al. Improved assessment of body cell mass by segmental bioimpedance analysis in malnourished subjects and acromegaly. Clinical Nutrition. 2003; 23(2): 167-174. Erratum in: Clinical Nutrition. 2004; 23(2): 285-286. http://dx.doi.org/10.1054/clnu.2002.0617
  4. Czerniec SA, Ward LC, Lee MJ, Refshauge KM, Beith J, Kilbreath SL. Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy. Supportive Care in Cancer. 2011; 19(5): 703-710. http://dx.doi.org/10.1007/s00520-010-0896-810.1007/s00520-010-0896-8
  5. Stokes IAF, Laible JP, Gardner-Morse MG, Costi JJ, Latridis JC. Refinement of Elastic, Poroelastic, and Osmotic Tissue Properties of Intervertebral Disks to Analyze Behavior in Compression. Annals of Biomedical Engineering. 2011; 39(1): 122-133. http://dx.doi.org/10.1007/s10439-010-0140-110.1007/s10439-010-0140-120711754
  6. Berry GP, Bamber JC, Mortimer PS, Bush NL, Miller NR, Barbone PE. The spatio-temporal strain response of oedematous and nonoedematous tissue to sustained compression in vivo. Ultrasound in Medicine & Biology. 2008; 34(4): 617-629. http://dx.doi.org/10.1016/j.ultrasmedbio.2007.10.00710.1016/j.ultrasmedbio.2007.10.00718222033
  7. O'Sullivan SB, Schmitz TJ. Physical rehabilitation: assessment and treatment. 5th ed. Philadelphia, Pa: FA Davis Company; 2001.
  8. Hogan MA, Madayag TM. Medical-Surgical Nursing: Reviews & Rationales. Upper Saddle River, NJ: Pearson Prentice Hall; 2004.
  9. Agarwal R, Andersen MJ, Pratt JH. On the importance of pedal edema in hemodialysis patients. Clinical Journal of the American Society of Nephrology. 2008; 3(1): 153–158. http://dx.doi.org/10.2215/CJN.0365080710.2215/CJN.03650807
  10. Zhu F, Kuhlmann MK, Kotanko P, Seibert E, Leonard EF, Levin NW. A method for the estimation of hydration state during hemodialysis using a calf bioimpedance technique. Physiological measurement. 2008; 29(6): S503-16. http://dx.doi.org/10.1088/0967-3334/29/6/S4210.1088/0967-3334/29/6/S4218544816
  11. Lowe A, Jones RW, Harrison MJ. The graphical presentation of decision support information in an intelligent anesthesia monitor. Artificial Intelligence in Medicine. 2001; 22(2): 173-191. http://dx.doi.org/10.1016/S0933-3657(00)00106-810.1016/S0933-3657(00)00106-8
  12. Imhoff M, Kuhls S, Gather U, Fried R. Smart alarms from medical devices in the OR and ICU. Best Practice & Research Clinical Anaesthesiology. 2009; 23(1): 39-50. http://dx.doi.org/10.1016/j.bpa.2008.07.0081944961510.1016/j.bpa.2008.07.008
  13. Kotanko P, Levin NW, Zhu F. Current state of bioimpedance technologies in dialysis. Nephrology Dialysis Transplantation. 2008; 23: 808-812. http://dx.doi.org/10.1093/ndt/gfm889
  14. Zhu F, Schneditz D Levin NW. Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis reduces sensitivity to changes in body position. Kidney International. 1999; 56(2): 692-699. http://dx.doi.org/10.1046/j.1523-1755.1999.00588.x10.1046/j.1523-1755.1999.00588.x10432410
  15. Schoeller DA, Alon A, Manekas D, Mixson LA, Lasseter KC, Noonan GP, et al. Segmental Bioimpedance for Measuring Amlodipine-Induced Pedal Edema: A Placebo-Controlled Study. Clinical Therapeutics. 2012; 34(3): 580-592. http://dx.doi.org/10.1016/j.clinthera.2012.01.0182238592710.1016/j.clinthera.2012.01.018
  16. Cornish BH, Jacobs A, Thomas BJ, Ward LC. Optimizing electrode sites for segmental bioimpedance measurements. Physiol. Meas. 1999; 20(3): 241-250.1047557810.1088/0967-3334/20/3/302
  17. Chongthanakorn K, Tiranathanagul K, Susantitaphong P, Praditpornsilpa K, Eiam-Ong S. Effective determination of dry weight by intradialytic bioimpedance analysis in hemodialysis. Blood Purification. 2009; 27(3): 235-241. http://dx.doi.org/10.1159/0001994281919039610.1159/000199428
  18. Lowe A, Jones RW, Harrison MJ. The graphical presentation of decision support information in an intelligent anesthesia monitor. Artificial Intelligence in Medicine. 2001; 22(2): 173-191. http://dx.doi.org/10.1016/S0933-3657(00)00106-810.1016/S0933-3657(00)00106-8
  19. Titze J, Luft FC, Bauer K, Dietsch P, Lang R, Veelken R, et al., Extrarenal Na+ balance, volume, and blood pressure homeostasis in intact and ovariectomized deoxycorticosterone-acetate salt rats. Hypertension. 2006; 47(6): 1101-1107. http://dx.doi.org/10.1161/01.HYP.0000221039.17735.1a1663619610.1161/01.HYP.0000221039.17735.1a
  20. Titze J, Shakibaei M, Schafflhuber M, Schulze-Tanzil G, Porst M, Schwind KH, et al. Glycosaminoglycan polymerization may enable osmotically inactive Na+ storage in the skin. American Journal of Physiology-Heart and Circulatory Physiology. 2004; 287(1): H203-208. http://dx.doi.org/10.1152/ajpheart.01237.200310.1152/ajpheart.01237.200314975935
  21. Ebah LM, Wiig H, Dawidowska I, O'Toole C, Summers A, Nikam M, et al. Subcutaneous interstitial pressure and volume characteristics in renal impairment associated with edema. Kidney International. 2013; 84: 980-988. http://dx.doi.org/10.1038/ki.2013.2082373923110.1038/ki.2013.208
  22. Rees AE, Ward LC, Cornish BH, Thomas BJ. Sensitivity of multiple frequency bioelectrical impedance. Physiol. Meas. 1999; 20: 349–362. http://dx.doi.org/10.1088/0967-3334/20/4/3021059322810.1088/0967-3334/20/4/302
  23. Gabrielli D, Kristal B, Katzarski K, Youssef M, Hachache T, Lopot F, et al., Improved intradialytic stability during haemodialysis with blood volume-controlled ultrafiltration. Journal of Nephrology. 2009; 22(2): 232-240.19384841
  24. Kohandel M, Sivaloganathan S, and Tenti G. Estimation of the quasi-linear viscoelastic parameters using a genetic algorithm. Mathematical and computer modeling. 2008; 47(3-4): 266-270. http://dx.doi.org/10.1016/j.mcm.2007.04.00610.1016/j.mcm.2007.04.006
  25. Dodde RE, Bull J, and Shih A. Bioimpedance of soft tissue under compression. Physiological Measurement. 2012; 33: 1095. http://dx.doi.org/10.1088/0967-3334/33/6/109510.1088/0967-3334/33/6/109522621935
  26. Keshtkar A. The effect of applied pressure on the electrical impedance of the bladder tissue using small and large probes. Journal of Medical Engineering and Technology. 2008; 32(6): 505-511. http://dx.doi.org/10.1080/0309190070150745610.1080/03091900701507456
  27. Belmont B, Dodde RE, Shih AJ. Impedance of tissue-mimicking phantom material under compression. Journal of Electrical Bioimpedance. 2013; 4: 2-12. http://dx.doi.org/10.5617/jeb.443
  28. Nordbotten BJ. Bioimpedance Measurements Using the Integrated Circuit AD5933. [dissertation] Oslo, Norway: Department of Physics, University of Oslo; 2008.
  29. Dodde R., Kruger, G., Shih, A. Design of Bioimpedance Spectroscopy Instrument with Compensation Techniques for Soft Tissue Characterization. ASME Journal of Medical Devices. Forthcoming 2014.
  30. Grimnes S, and Martinsen OG. Bioimpedance and bioelectricity basics. 2nd ed. Oxford, UK: Academic Press; 2008.
  31. Steendijk P, Baan J, Mur G, Van Der Velde ET. The four-electrode resistivity technique in anisotropic media: theoretical analysis and application on myocardial tissue in vivo. IEEE Transactions on Biomedical Engineering. 1993; 40(11): 1138-1148. http://dx.doi.org/10.1109/10.24563210.1109/10.245632
  32. Cole KS, Cole RH. Dispersion and absorption in dielectrics I. Alternating current characteristics. The Journal of Chemical Physics. 1941; 9: 341-351. http://dx.doi.org/10.1063/1.1750906
  33. Elwakil AS, Maundy B. Extracting the Cole-Cole impedance model parameters without direct impedance measurement. Electronics Letters. 2010; 46: 1367-1368. http://dx.doi.org/10.1049/el.2010.192410.1049/el.2010.1924
  34. Cole, K.S. Permeability and impermeability of cell membranes for ions. Cold Spring Harb. Symp. Quant. Biol. 1940; 8: 110-122. http://dx.doi.org/10.1101/SQB.1940.008.01.01310.1101/SQB.1940.008.01.013
  35. Hanai T. Electrical properties of emulsions. In: Sherman DH (ed) Emulsions science. 1994; Academic Press, London, 354-477.
  36. Fung YC. Biomechanics: Mechanical Properties of Living Tissues, 2nd ed. New York, NY: Springer-Verlag; 1993. http://dx.doi.org/10.1007/978-1-4757-2257-4
  37. Onaral B, Schwan HP. Linear and nonlinear properties of platinum electrode polarization. Part 1: frequency dependence at very low frequencies. Med. & Biol. Eng. & Comput. 1982; 20: 299–306. http://dx.doi.org/10.1007/BF02442796
  38. Onaral B, Schwan HP. Linear and nonlinear properties of platinum electrode polarization. Part 2: Time domain analysis. Med. & Biol. Eng. & Comput. 1983; 21: 210–216. http://dx.doi.org/10.1007/BF02441540
  39. Schwan HP. Alternating current electrode polarization. Biophysik. 1966; 3: 181-201. http://dx.doi.org/10.1007/BF0119161210.1007/BF01191612
  40. Zaluska W, Malecka T, Mozul S, Ksiazek A. Whole body versus segmental bioimpedance measurements (BIS) of electrical resistance (Re) and extracellular volume (ECV) for assessment of dry weight in end-stage renal patients treated by hemodialysis. Przegl Lek. 2004; 61(2): 70-3. In Polish.15230144
  41. Jaffrin MY, Morel H. Extracellular volume measurements using bioimpedance spectroscopy – Hanai method and wrist-ankle resistance at 50 kHz. Med. Biol Comput. 2009; 47(1): 77-84. http://dx.doi.org/10.1007/s11517-008-0394-z10.1007/s11517-008-0394-z
  42. Zhu F, Schneditz D, Wang E, Martin K, Morris AT, and Levin NW. Validation of changes in extracellular volume measured during hemodialysis using a segmental bioimpedance technique. ASAIO J. 1998; 44: 541–545. http://dx.doi.org/10.1097/00002480-199809000-0004510.1097/00002480-199809000-00045
DOI: https://doi.org/10.5617/jeb.929 | Journal eISSN: 1891-5469
Language: English
Page range: 99 - 109
Submitted on: Sep 4, 2014
Published on: Dec 25, 2014
Published by: University of Oslo
In partnership with: Paradigm Publishing Services
Publication frequency: 1 issue per year

© 2014 Leo Koziol, John J. Pitre, Joseph L. Bull, Robert E. Dodde, Grant Kruger, Alan Vollmer, William F. Weitzel, published by University of Oslo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.