References
- Facius M, Malich A, Schneider G, Boehm T, Anderson R, and Kaiser W. Electrical Impedance Scanning used in addition to ultrasound for the verification of submandibular and parotid lesions: initial results. Invest. Radiol. 2002;37(8):421–427. http://dx.doi.org/10.1097/00004424-200208000-0000210.1097/00004424-200208000-0000212138357
- Krishnan K, Liu J, Thomas S, and Kohli K. A Phantom to Assess EIT/CT Imaging System. In 55th AAPM, 2013.
- Robinson MP, Richardson MJ, Green LJ, and Preece AW. New materials for dielectric simulation of tissues. Phys. Med. Biol. 1991;36(12):1565–1571. http://dx.doi.org/10.1088/0031-9155/36/12/00210.1088/0031-9155/36/12/0021771180
- Porter E, Fakhoury J, Oprisor R, Coates M, and Popovic M. Improved Tissue Phantoms for Experimental Validation of Microwave Breast Cancer Detection. Proceedings of the Fourth European Conference on Antennas & Propagation (EuCAP). 2010: pp. 1–5.
- Chen R and Shih A. Multi-modality gellan gum-based tissue-mimicking phantom with targeted mechanical, electrical, and thermal properties. Phys. Med. Biol. 2013;58(16):5511–5525. http://dx.doi.org/10.1088/0031-9155/58/16/551110.1088/0031-9155/58/16/5511
- Ramaseshan R, Kohli K, Cao F, and Heaton R. Dosimetric evaluation of Plastic Water Diagnostic Therapy. J. Appl. Clin. Med. Phys. 2008;9(2),98-111.10.1120/jacmp.v9i2.2761
- Banaee N, Nedaie HA, Nosrati H, Nabavi M, and Naderi M. Dose Measurement of Different Bolus Materials on Surface Dose. J. Radioprot. Res. 2013;1(1):10–13.10.12966/jrr.08.02.2013
- Seppala T, Collan J, Auterinen Ii, and Seren T. A dosimetric study on the use of bolus materials for treatment of superficial tumors with BNCT. Appl. Radiat. Isot. 2004;61:787–791. http://dx.doi.org/10.1016/j.apradiso.2004.05.05410.1016/j.apradiso.2004.05.054
- Spitz H, Jenkins M, Lodwick J, and Bornschein R. A new anthropometric phantom for calibrating in vivo measurments of stable lead in the human leg using x-ray fluorescence. Health Phys. 2000;78(2):159–169. http://dx.doi.org/10.1097/00004032-200002000-0000510.1097/00004032-200002000-00005
- Freed M, Badal A, Jennings RJ, de las Heras H, Myers KJ, and Badano A. X-ray properties of an anthropomorphic breast phantom for MRI and X-ray imaging. Phys. Med. Biol. 2011;56(12):3513-3545. http://dx.doi.org/10.1088/0031-9155/56/12/0052160655610.1088/0031-9155/56/12/005
- "Superflab." [Online]. Available: http://www.micknuclear.com/page_external_beam/external_beam_accessories3.asp Accessed: 11 Dec 2013.
- Marchal C, Nadi M, Tosser A, Roussey C, and Gaulard M. Dielectric properties of gelatine phantoms used for simulations of biological tissues between 10 and 50 MHz. Int. J. Hyperth. 1989;5(6):725–732. http://dx.doi.org/10.3109/0265673890914049710.3109/02656738909140497
- Oh TI, Koo H, Lee KH, Kim SM, Lee J, Kim SW, Seo JK, and Woo EJ. Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging. Physiol. Meas. 2008;29(3):295–307. http://dx.doi.org/10.1088/0967-3334/29/3/00210.1088/0967-3334/29/3/00218367806
- "Zurich Instruments." [Online]. Available: http://www.zhinst.com/products/hf2is Accessed: 11 Dec 2013.
- "American National Standards: Safe Current Limit for electromedical appparatus guidelines." [Online]. Available: http://courses.engr.illinois.edu/ece445/documents/Safe_Current_Limits.pdf Accessed: 11 Dec 2013.
- Halter RJ and Al E. The correlation of in vivo and ex vivo tissue dielectric properties to validate electromagnetic breast imaging: initial clinical experience. Physiol. Meas. 2009;30:S121–S136. http://dx.doi.org/10.1088/0967-3334/30/6/S0810.1088/0967-3334/30/6/S0819491436
- Foster K and Schwan HP. Dielectric Properties of Tissues and Biological Materials: A Critical Review. Crit. Rev. Biomed. Eng. 1989;17(1):25–104.2651001
- Winter J, et al. The Material Properties of Gelatin Gels. National Technical Information Service. US Dept. of Commerce.1975.
- Grimnes S and Martinsen OG. Bioimpedance and Bioelectricity Basics. 2. ed. Elsevier Science. 2008.