Have a personal or library account? Click to login
A system to monitor segmental intracellular, interstitial, and intravascular volume and circulatory changes during acute hemodialysis Cover

A system to monitor segmental intracellular, interstitial, and intravascular volume and circulatory changes during acute hemodialysis

Open Access
|Jul 2017

References

  1. Boyd JH, Forbes J, Nakada T, Walley KR, Russell JA (2011) Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit. Care Med. 39(2):259-65 https://doi.org/10.1097/CCM.0b013e3181feeb15
  2. Maisch B, Dristic A (2003) Practical aspects of the management of pericardial disease. Heart 89:1096-1103https://doi.org/10.1136/heart.89.9.1096
  3. Jaeger JQ, Mehta RL (1999) Assessment of dry weight in hemodialysis: An overview. J. Am. Soc. Nephrol. 10:392-403
  4. Montgomery LD, Dietrich MS, Armer JM, Stewart BR, Ridner SH (2011) Segmental blood flow and hemodynamic state of lymphedematous and non-lymphedematous arms. Lymphat. Res. Biol. 9(1):31-42 https://doi.org/10.1089/lrb.2010.0012
  5. Nanovic L (2005) Electrolytes and fluid management in hemodialysis and peritoneal dialysis. Nutr. Clin. Pract. 20(2):192-201 https://doi.org/10.1177/0115426505020002192
  6. Ridner SH, Montgomery LD, Hepworth JT, Stewart BR, Armer JM (2007) Comparison of upper limb volume measurement techniques and arm symptoms between healthy volunteers and individuals with known lymphedema. Lymphology 40(1):35-46
  7. Montgomery LD, Hanish HM, Marker RA (1989) An impedance device for study of multisegmental hemodynamic changes during orthostatic stress. Aviat. Space Environ Med. 60:116-22
  8. Stewart JM, Medow MS, Glover JL, Montgomery LD (2006) Persistent splanchnic hyperemia during upright tilt in postural tachycardia syndrome. Am. J. Physiol. Heart Circ. Physiol. 290:H665-H673 https://doi.org/10.1152/ajpheart.00784.2005
  9. Nyboer J (1959) Electrical impedance plethysmography; the electrical resistive measure of the blood pulse volume, peripheral and central blood flow. Thomas, Springfield, IL
  10. Mohapatra SN, Arenson HM (1979) The measurement of peripheral blood flow by electrical impedance technique. J. Med. Eng. Tech. 3:132-137 https://doi.org/10.3109/03091907909162092
  11. Anderson FA Jr, Penney BC, Patwardhan NA, Wheeler HB (1980) Impedance plethysmography: the orgin of electrical impedance changes measured in the human calf. Med. Biol. Eng. Comput. 18:234-240 https://doi.org/10.1007/BF02443300
  12. Yamamoto Y, Yamamoto T, Oberg PA (1992) Impedance plethysmography for blood flow measurements in human limbs: Part 2 Influence of limb cross-sectional area. Med. Biol. Eng. Comput. 30:518-524 https://doi.org/10.1007/bf02457831
  13. Jain AK, Lindsay RM (2008) Intra and extra cellular fluid shifts during the inter dialytic period in conventional and daily hemodialysis patients. ASAIO Journal 100-103 https://doi.org/10.1097/MAT.0b013e318162c404
  14. Sasser DC, Gerth WA, Wu YC (1993) Monitoring of segmental intra- and extracellular volume changes using electrical impedance spectroscopy. J. Appl. Physiol. 74:2180-2187
  15. Ackman JJ, Seitz MA (1984) Methods of complex impedance measurement in biologic tissue. CRC Crit. Rev. Biomed. Eng. 11:281-311
  16. Kanai H, Katsuyuki S, Haeno M (1983) Electrical measurement of fluid distribution in human legs: Estimation of extra- and intracellular fluid volume. J. Microwave Power 18:233-43 https://doi.org/10.1080/16070658.1983.11689328
  17. Jaffrin MY, Fenech M, DeFremont JF, Tolane M (2002) Continuous monitoring of plasma, interstitial, and intracellular fluid volumes in dialyzed patients by bioimpedance and hematocrit measurements. ASAIO Journal 48:326-333 https://doi.org/10.1097/00002480-200205000-00021
  18. Jain AK, Lindsay RM (2008) Intra and extra cellular fluid shifts during the inter dialytic period in conventional and daily hemodialysis patients. ASAIO Journal 100-103 https://doi.org/10.1097/MAT.0b013e318162c404
  19. Jaffrin MY, Morel H (2009) Extracellular volume measurements using bioimpedance spectroscopy-Hanai method and wrist-ankle resistance at 50 kHz. Med. Biol. Eng. Comput. 47:77-84 https://doi.org/10.1007/s11517-008-0394-z
  20. Jindal GD (1986) Impedance plethysmography for screening vascular disorders. J. Postgrad. Med. 32:1-3
  21. Cole KS, Cole RH (1941) Dispersion and absorption in dielectrics. J. Chem. Phys. 9: 341-352 https://doi.org/10.1063/1.1750906
  22. Sasser DC, Gerth WA, Wu YC. Monitoring of segmental intraand extracellular volume changes using electrical impedance spectroscopy. J. Appl. Physiol. 1993;74:2180-2187
  23. Gerth WA, Montgomery LD, Wu YC (1990) A computer-based bioelectrical impedance spectroscopic system for noninvasive assessment of compartmental fluid redistribution. In; Proceedings of Third Annual IEEE Symposium on Computer- Based Medical Systems. IEEE Computer Society Press, Chapel Hill, NC: 446-453 https://doi.org/10.1109/CBMSYS.1990.109432
  24. Gerth WA, Watke CM (1993) Electrical impedance spectroscopic monitoring of body compartment volume changes. J. Clin. Eng. 18(3):253-260 https://doi.org/10.1097/00004669-199305000-00016
  25. Fricke H (1924) A mathematical treatment of electric conductivity and capacity of disperse systems. I. The electric conductivity of a suspension of homogeneous spheroids. Phys. Rev. 24:575-587 https://doi.org/10.1103/physrev.24.575
  26. Fricke H (1925) A mathematical treatment of electric conductivity and capacity of disperse systems. II. The capacity of a suspension of conducting spheroids surrounded by a nonconducting membrane for a current of low frequency. Phys. Rev. 26:678-681 https://doi.org/10.1103/physrev.26.678
  27. Fricke H (1925) The electric capacity of suspensions of red corpuscles of a dog. Phys. Rev. 26:682-687 https://doi.org/10.1103/PhysRev.26.682
  28. Fricke H, Morse S (1925) The electric resistance and capacity of blood for frequencies between 800 and 4.5 million cycles. J. Gen. Physiol. 9:153-167 https://doi.org/10.1085/jgp.9.2.153
  29. Fricke H (1953) The electric permittivity of a dilute suspension of membrane-covered ellipsoids. J. Appl. Phys. 24:644-646 https://doi.org/10.1063/1.1721343
  30. Gerth WA, Montgomery LD, Wu YC (1990) A computer-based bioelectrical impedance spectroscopic system for noninvasive assessment of compartmental fluid redistribution. In; Proceedings of Third Annual IEEE Symposium on Computer-Based Medical Systems. IEEE Computer Society Press, Chapel Hill, NC: 446-453 https://doi.org/10.1109/CBMSYS.1990.109432
  31. Montgomery LD, Gerth WA, Montgomery RW, Lew SQ, Klein MD, Stewart JM, Velasquez MT (2013) Monitoring intracellular, interstitial, and intravascular volume changes during fluidmanagement procedures. Med. Biol. Eng. Comput. 51:1167-1175 https://doi.org/10.1007/s11517-013-1064-3
  32. Montgomery LD, Montgomery RW, Gerth WA, Lew SQ, Klein MD, Stewart JM, Medow M, Velasquez MT (2016) Bioimpedance monitoring of cellular hydration during hemodialysis therapy. Hemo. Int. In Press 10.1111/hdi.12511https://doi.org/10.1111/hdi.12511
  33. Rodriguez HJ, Domenici R, Diroll A, Goykhman I. Assessment of dry weight changes in blood volume during hemodialysis using Crit-line. Kidney Int. 2005;68:854-861. https://doi.org/10.1111/j.1523-1755.2005.00467.x
  34. Sinha AD, Light RP, Agarwal R. Relative plasma volume monitoring during hemodialysis aids the assessment of dry weight. Hypertension 2010;55:305-311. https://doi.org/10.1161/HYPERTENSIONAHA.109.143974
  35. Federal Drug Administration (2002) K011741 Premarket Approval Crit-Line IIITQA URR Monitor
  36. Federal Drug Administration (2010) K093834 Premarket Approval Crit-Line Anemia Management Monitor
  37. Lew SQ, Velasquez MT, Montgomery LD, Gerth WA, Montgomery RW (20130 Monitoring intracellular (IC), interstitial (IS) and intravascular (IV) volume changes during dialysis (HD) in a chronic unit (CU) compared to acute unit (AU) setting. Presented at the Annual meeting of the American Society of Nephrology, At Atlanta, GA, USA.
  38. Durbin J, Watson G S (1950) Testing for serial correlation in least squares regression, I. Biometrika 37, 409–428. https://doi.org/10.1093/biomet/37.3-4.409
  39. Bland J, Altman DG (1996) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-313
DOI: https://doi.org/10.5617/jeb.4443 | Journal eISSN: 1891-5469
Language: English
Page range: 40 - 53
Submitted on: Feb 14, 2017
Published on: Jul 3, 2017
Published by: University of Oslo
In partnership with: Paradigm Publishing Services
Publication frequency: 1 issue per year

© 2017 Leslie D. Montgomery, Richard W. Montgomery, Wayne A. Gerth, Marty Loughry, Susie Q. Lew, Manuel T. Velasquez, published by University of Oslo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.