Have a personal or library account? Click to login
Geometric parameters optimization of planar interdigitated electrodes for bioimpedance spectroscopy Cover

Geometric parameters optimization of planar interdigitated electrodes for bioimpedance spectroscopy

By: M. Ibrahim,  J. Claudel,  D. Kourtiche and  M. Nadi  
Open Access
|Mar 2013

References

  1. Grimnes S, Martinsen OG. Bioimpedance and Bioelectricity Basics. Academic Press; 2000.
  2. Faes TJ, Meij HA, De Munck JC, Heethaar RM. The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies. Physiol Meas 1999, 20:R1-10. http://dx.doi.org/10.1088/0967-3334/20/4/2011059322610.1088/0967-3334/20/4/201
  3. Katz E, Willner I. Probing Biomolecular Interactions at Conductive and Semiconductive Surfaces by Impedance Spectroscopy: Routes to Impedimetric Immunosensors, DNA-Sensors, and Enzyme Biosensors. Electroanalysis, 15 (11), 913-947, 2003. http://dx.doi.org/10.1002/elan.20039011410.1002/elan.200390114
  4. Sheppard NF, Tucker RC, Wu C. Electrical-Conductivity Measurements Using Microfabricated Interdigitated Electrodes. Analytical Chemistry, 1993, 65(9), p. 1199-1202. http://dx.doi.org/10.1021/ac00057a01610.1021/ac00057a016
  5. Mukhopadhyay SC. Sensing and Instrumentation for a Low Cost Intelligent Sensing System. SICE-ICASE International Joint Conference, Bexco, Busan, Korea, pp 1075-1080, Oct 2006. http://dx.doi.org/10.1109/SICE.2006.315815
  6. Mukhopadhyay SC, Gooneratne CP, Demidenko S, Sen Gupta G. Low cost sensing system for dairy products quality monitoring. Proceedings of 2005 International Instrumentation and Measurement Technology Conference, Ottawa, Ont 2005, IEEE Catalog Number 05CH37627C, ISBN 0-7803-8880-1, 244-249.
  7. Van Gerwen P, Laureyn W, Laureys W, Huyberechts G, Op De Beeck M, Baert K, Suls F, Sansen W, Jacobs P, Hermans L, Mertens R. Nanoscaled interdigitated electrode arrays for biochemical sensors. Sens. Actuators, B 49.1999.73–80.
  8. Timms S, Colquhoun KO, Fricker CR. Detection of Escherichia coli in potable water using indirect impedance technology. J. Microbiol, Meth, 26(1996) 125. http://dx.doi.org/10.1016/0167-7012(96)00903-710.1016/0167-7012(96)00903-7
  9. Geng P, Zhang X, Meng W, Wang Q, Jin L, Feng Z, Wu Z. Self-assembled monolayers-based immunosensor for detection of Escherichia coli using electrochemical impedance spectroscopy. Electrochim, Acta 53 (2008) 4663. http://dx.doi.org/10.1016/j.electacta.2008.01.03710.1016/j.electacta.2008.01.037
  10. Franks W, Schenker I, Schmutz P, Hierlemann A, Impedance characterization and modeling of electrodes for biomedical applications. 2005. IEEE Trans. Biomed. Eng. 52, 1295–1302. http://dx.doi.org/10.1109/TBME.2005.8475231604199310.1109/TBME.2005.847523
  11. Hong J, Yoon DS, Kim SK, Kim TS, Kim S, Pak EY, et al. AC frequency characteristics of coplanar impedance sensors as design parameters. Lab Chip. 2005;5(3):270-279. http://dx.doi.org/10.1039/b410325d10.1039/b410325d15726203
  12. Linderholm P, Bertsch A, Renaud P. Resistivity probing of multi-layered tissue phantoms using microelectrodes. Physiol Meas. 2004 Jun; 25(3):645-658. http://dx.doi.org/10.1088/0967-3334/25/3/0051525311610.1088/0967-3334/25/3/005
  13. Olthuis W et al. Theoretical and experimental determination of cell constants of planar-interdigitated electrolyte conductivity sensors. Sensors and Actuators B 24-25 (1995) 252-256. http://dx.doi.org/10.1016/0925-4005(95)85053-8
  14. Igreja R, Dias CJ. Analytical evaluation of the inter-digital electrodes capacitance for a multi-layered structure. Sensors and actuators A 112 (2004) 291-301. http://dx.doi.org/10.1016/j.sna.2004.01.04010.1016/j.sna.2004.01.040
  15. Grimnes S, Martinsen OG. Bioimpedance and bioelectricity basics. 2nd ed. Academic; 2008.
  16. Bard AJ, Faulkner LR. Electrochemical methods, fundamentals and applications, John Wiley and Sons, New York, 1980.
  17. Ibrahim M, Kourtiche D, Nadi M. The influence of interdigitated electrode configuration modeling for the bioimpedance of biological medium. Proceedings of 2010 4th International Conference on Sensing Technology Lecce, Italia, pp. 578-581.
  18. Timmer B, Sparreboom W, Olthuis W, Bergveld P, Berg AVD. Optimization of an electrolyte conductivity detector for measuring low ion concentrations. Lab Chip. 2002;2(2):121-124. http://dx.doi.org/10.1039/b201225a10.1039/b201225a15100845
  19. CRM, Formulaires et tables, ed. Tricorne. 2000.
  20. CoventoreWare® Analyzer version 2010. Reference MEMS and Microsystems Design, section MemElectro. www.coventor.com
  21. Bard AJ, Faulkner LR. Electrochemical Methods, New York, Willey, 2001.
  22. Dielectric Properties of Body Tissues in the frequency range 10Hz-100GHz. www.niremf.ifac.cnr.it/tissprop/htmlclie/htmlclie.htm
  23. Jaspard F, Nadi M, Rouane A. Dielectric properties of blood : an investigation of haematocrit dependance, Physiological Measurement, Vol 24 pages 134-147, 2003. http://dx.doi.org/10.1088/0967-3334/24/1/310
  24. Zimmerman WBJ. Multiphysics Modeling With Finite Element Methods (Series on Stability, Vibration and Control of Systems, Serie). World Scientific Publishing Co., Inc. River Edge, NJ, USA, 2006.
  25. Alexander Frank Jr, Price Dorielle T, Bhansali, Shekhar, Optimization of Interdigitated Electrode (IDE) Arrays for Impedance Based Evaluation of Hs 578T Cancer Cells, J. Phys.: Conf. Ser. 224 012134, Volume 224, Issue 1, pp. 012134 (2010).
DOI: https://doi.org/10.5617/jeb.304 | Journal eISSN: 1891-5469
Language: English
Page range: 13 - 22
Submitted on: Jun 4, 2012
Published on: Mar 1, 2013
Published by: University of Oslo
In partnership with: Paradigm Publishing Services
Publication frequency: 1 issue per year

© 2013 M. Ibrahim, J. Claudel, D. Kourtiche, M. Nadi, published by University of Oslo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.