References
- Davey CL, Davey HM, Kell DB. On the Dielectric Properties of Cell Suspensions at High Volume Fractions. Bioelectrochemistry and Bioenergetics. 1992;28:319-340. http://dx.doi.org/10.1016/0302-4598(92)80023-A10.1016/0302-4598(92)80023-A
- Coster HGL, Chilcott TC, Coster ACF. Impedance spectroscopy of interfaces, membranes and ultrastructures. Bioelectrochemistry and Bioenergetics. 1996;40:79-98. http://dx.doi.org/10.1016/0302-4598(96)05064-710.1016/0302-4598(96)05064-7
- Bordi F, Cametti C, Colby RH. Dielectric spectroscopy and conductivity of polyelectrolyte solutions. J. Phys: Condens. Matter. 2004;16:R1423-R1463. http://dx.doi.org/10.1088/0953-8984/16/49/R01
- Felice CJ, Monitor Digital de Microorganismos: Aspectos Teóricos y Tecnológicos [PhD Dissertation]. Universidad Nacional de Tucumán, San Miguel de Tucumán. 1999.
- Geddes LA. Who Introduced the Tetrapolar Method for Measuring Resistance and Impedance? IEEE Engineering in Medicine and Biology Magazine. 1996;15:133-134. http://dx.doi.org/10.1109/51.53707010.1109/51.537070
- Prodan C, Mayo F, Claycomb JR, Miller JH, Benedik MJ. Low-frequency, low-field dielectric spectroscopy of living cell suspensions. J. Appl. Phys. 2004;95:3754-3756. http://dx.doi.org/10.1063/1.164945510.1063/1.1649455
- Schwan HP, Ferris CD. Four-Electrode Null Tecniques for impedance Measurement with High Resolution. The Review of Scientific Instruments. 1968;39:481-485. http://dx.doi.org/10.1063/1.168341310.1063/1.1683413
- Brown BH, Smallwood RH, Barber DC, Lawfoed PV, Rose DR. Medical Physics and Biomedical Engineering. IOP Plublishing, London, 1999 http://dx.doi.org/10.1887/0750303689
- Cornish BH, Jacobs A, Thomas BJ, Ward LC. Optimizing electrode sites for segmental bioimpedance measurements. Physiol. Meas. 1999;20:241-250. http://dx.doi.org/10.1088/0967-3334/20/3/3021047557810.1088/0967-3334/20/3/302
- Scharfetter H, Structural Modeling for Impedance-Based Non-Invasive Diagnostic Methods [PhD Dissertation]. Faculty of Electrical Engineering, Technical University Graz, Graz, 1999
- Kim SG, Sung PY, Han J, Suk WN, Tae HL, Oh IH, Hong, SA. A study on the chemical stability and electrode performance of modified NiO cathodes for molten carbonate fuel cells. Electrochimica Acta. 2004;49:3081–3089 http://dx.doi.org/10.1016/j.electacta.2004.01.02710.1016/j.electacta.2004.01.027
- Kybert J, Hansgent H, Pliquetti F. Dielectric properties of biological tissue at low temperatures demonstrated on fatty tissue. Phys. Med. Biol.1992;37:1675-1688 http://dx.doi.org/10.1088/0031-9155/37/8/004151890710.1088/0031-9155/37/8/004
- Baysal U, Eyüboglu BM. Tissue resistivity estimation in the presence of positional and geometrical uncertainties. Phys. Med. Biol. 2000;45:2373-2388 http://dx.doi.org/10.1088/0031-9155/45/8/32210.1088/0031-9155/45/8/32210958201
- Grimnes S, Martinsen OG. Sources of error in tetrapolar impedance measurements on biomaterials and other ionic conductors. J. Phys. D: Appl. Phys. 2007;40:9–14 http://dx.doi.org/10.1088/0022-3727/40/1/S0210.1088/0022-3727/40/1/S02
- Brown BH, Tidy JA, Boston K, Blackett AD, Smallwood RH, Sharp F. Relation between tissue structure and imposed electrical current flow in cervical neoplasia. The Lancet. 2000;355:892-895 http://dx.doi.org/10.1016/S0140-6736(99)09095-910.1016/S0140-6736(99)09095-9
- González-Correa CA, Brown BH, Smallwood RH, Kalia N, Stoddard CJ, Stephenson TJ, Haggie SJ, Slater DN, Bradman KD. Virtual biopsies in Barret’s esophagous using impedance probe. Ann. NY Acad. Sci. 1999;873: 313-321 http://dx.doi.org/10.1111/j.1749-6632.1999.tb09479.x10.1111/j.1749-6632.1999.tb09479.x
- Less A, Shenstone Richards JC, Jason AC. Methods and apparatus for determining the condition of food. US Patent No. 3665302, 1972
- Kislov AV, Novikov IA, Petrovych SV, Khomyakov ON. Biological signal sensor and device for recording biological signals incorporating the said sensor. US Patent No. 6.996.428, 2006
- Foster KR, Schwan HP. Dielectric Properties of Tissues and Biological Materials, A Critical Review. Critical Reviews in Biomedical Engineering. 1989;17:25-1042651001
- Jontes JD. Theories of muscle contraction, Journal of Structure Biology. 1985;115:119-143 http://dx.doi.org/10.1006/jsbi.1995.1037
- Brosseau C. Modelling and simulation of dielectric heterostructures: a physical survey from an historical perspective. J. Phys. D: Appl. Phys. 2006;39:1277–1294 http://dx.doi.org/10.1088/0022-3727/39/7/S0210.1088/0022-3727/39/7/S02
- Simeonova M, Gimsa J. Dielectric anisotropy, volume potential anomalies and the persistent Maxwellian equivalent body, J. Phys.: Condens. Matter. 2005;17:7817–7831 http://dx.doi.org/10.1088/0953-8984/17/50/004
- Gómez-Sánchez JA, Felice CJ. Determination of bidirectional electric anisotropy of muscles ex vivo using three electrode configurations. IFMBE Proceedings WC 2009 World Congress on Medical Physics and Biomedical Engineering 25, 2009
- Steendijk P, Mur G, Van der Velde ET, Baan J. The four electrode resistivity technique in anisotropic media: Theorical analysis and application on myocardial tissue in vivo. IEEE Transations on Biomedical Engineering. 1993; 40:1138-1148 http://dx.doi.org/10.1109/10.24563210.1109/10.245632
- Zhao X, Kinouchi Y, Iritani T, Morimoto T, Takeuchi M. Estimation of Multi-Layer Tissue Conductivities from Non-Invasive Measured Bioresistances Using Divided Electrodes. IEICE Trans. Inf. & Syst. 2002;E85-D:1031-1038
- Gómez-Sánchez JA, Aristizábal Botero W, Barragán Arango PJ, Felice CJ. Introduction of a muscular bidirectional electrical anisotropy index to quantify the structural modifications during aging in raw meat. Measurement Science and Technology. 2009;20
- Chawla N, Chawla KK. Metal matrix composites. Springer Science + Business Media Inc, New York, 2006.
- Grimnes S, Martinsen OG. Bioimpedance and Bioelectricity Basics. Second Edition, Elsevier, Oxford, 2008
- Geddes LA, Foster KS, Reilly J, Voorhees WD, Bourland JD, Ragheb T, Fearnot NE. The rectification properties of an electrode-electrolyte interface operated at high sinusoidal current density. IEEE Transactions on Biomedical Engineering. 1987;34:669-672 http://dx.doi.org/10.1109/TBME.1987.325991
- Ruiz GA, Felice CJ, Valentinuzzi ME. Non-linear response of electrode–electrolyte interface at high current density. Chaos, Solutions and Fractals. 2005;25:649–654 http://dx.doi.org/10.1016/j.chaos.2004.11.02910.1016/j.chaos.2004.11.029
- Høyum P, Kalvøy H, Martinsen OG, Grimnes S. A finite element model of needle electrode spatial sensitivity. Physiol. Meas. 2010;31:1369–1379 http://dx.doi.org/10.1088/0967-3334/31/10/00610.1088/0967-3334/31/10/00620736490
- Pajkossy T. Impedance spectroscopy at interfaces of metals and aqueous solutions — Surface roughness, CPE and related issues. Solid State Ionics. 2005;176:1997–2003 http://dx.doi.org/10.1016/j.ssi.2004.06.02310.1016/j.ssi.2004.06.023
- Feldman Y, Nigmatullin R, Polygalov E, Texter J. Fractal-polarization correction in time domain dielectric spectroscopy. Physical Review E. 1998;58:7561-7565 http://dx.doi.org/10.1103/PhysRevE.58.756110.1103/PhysRevE.58.7561
- Halley JW, Studies of the interdependence of electronic and atomic dynamics and structure at the electrode-electrolyte interface. Electrochimica Acta. 1996;41:2229-2251 http://dx.doi.org/10.1016/0013-4686(96)00052-710.1016/0013-4686(96)00052-7
- Kalvøy H, Johnsen GK, Martinsen OG, Grimnes S. New Method for Separation of Electrode Polarization Impedance from Measured Tissue Impedance. The Open Biomedical Engineering Journal. 2011;5:8-13 http://dx.doi.org/10.2174/18741207011050100082162536910.2174/1874120701105010008
- Kottam ATG. Measurement of Electrical Admittance to Study the Onset and Progression of Myocardial Ischemia. ProQuest, USA, 2007