References
- World Health Organization (WHO). Global Atlas of Cardiovascular Disease Prevention and Control. Geneve: 2011.
- Vlachopoulos C, Aznaouridis K, Terentes-Printzios D, Ioakeimidis N, and Stefanadis C. Prediction of Cardiovascular Events and All-cause Mortality With Brachial-ankle Elasticity Index: A Systematic Review and Meta-analysis. J Hypertens. 2012; 60(2): 556–62. http://dx.doi.org/10.1161/HYPERTENSIONAHA.112.19477910.1161/HYPERTENSIONAHA.112.194779
- The Reference Values for Arterial Stiffness' Collaboration. Determinants of Pulse Wave Velocity in Healthy People and in the Presence of Cardiovascular Risk Factors: Establishing Normal and Reference Values. Eur Heart J. 2010; 31(19): 2338-50. http://dx.doi.org/10.1093/eurheartj/ehq16520530030
- Laurent S, Cockcroft J, Van Bortel L, Boutouyrie P, Giannattasio C, et al. Expert Consensus Document on Arterial Stiffness: Methodological Issues and Clinical Applications. Eur Heart J. 2006; 27(21): 2588–605. http://dx.doi.org/10.1093/eurheartj/ehl25410.1093/eurheartj/ehl25417000623
- Allen J. Photoplethysmography and Its Application in Clinical Physiological Measurement. Physiol Meas. 2007; 28(3): R1-R39. http://dx.doi.org/10.1088/0967-3334/28/3/R011732258810.1088/0967-3334/28/3/R01
- Risacher F, Jossinet J, McAdams ET, McLaughlin J, Mann Y, et al. Impedance Plethysmography for the Evaluation of Pulse Wave Velocity in Limbs. Med Biol Eng Comput. 1993; 31(3): 318–22. http://dx.doi.org/10.1007/BF02458053841238710.1007/BF02458053
- Asmar R, Benetos A, Topouchian J, Laurent P, Pannier B, et al. Assessment of Arterial Distensibility by Automatic Pulse Wave Velocity Measurement: Validation and Clinical Application Studies. J Hypertens. 1995; 26(3): 485–90. http://dx.doi.org/10.1161/01.HYP.26.3.48510.1161/01.HYP.26.3.485
- Salvi P, Lio G, Labat C, Ricci E, Pannier B, et al. Validation of a New Non-Invasive Portable Tonometer for Determining Arterial Pressure Wave and Pulse Wave Velocity: The PulsePen Device. J Hypertens. 2004; 22(12): 2285-93. http://dx.doi.org/10.1097/00004872-200412000-0001010.1097/00004872-200412000-0001015614022
- Buxi D, Redouté JM, and Yuce MR. A Survey on Signals and Systems in Ambulatory Blood Pressure Monitoring Using Pulse Transit Time. Physiol Meas. 2015; 36(3): R1–R26. http://dx.doi.org/10.1088/0967-3334/36/3/R12569423510.1088/0967-3334/36/3/R1
- Van Bortel LM, Laurent S, Boutouyrie P, Chowienczyk P, Cruickshank JK, et al. Expert Consensus Document on the Measurement of Aortic Stiffness in Daily Practice Using Carotid-femoral Pulse Wave Velocity. J Hypertens. 2012; 30(3): 445–8. http://dx.doi.org/10.1097/HJH.0b013e32834fa8b010.1097/HJH.0b013e32834fa8b022278144
- Wilkinson IB, McEniery CM, Schillaci G, Boutouyrie P, Segers P, et al. ARTERY Society Guidelines for Validation of Non-invasive Haemodynamic Measurement Devices: Part 1, Arterial Pulse Wave Velocity. Artery Res. 2010; 4(2): 34–40. http://dx.doi.org/10.1016/j.artres.2010.03.00110.1016/j.artres.2010.03.001
- Kööbi T, Kähönen M, Iivainen T, and Turjanmaa V. Simultaneous Non-invasive Assessment of Arterial Stiffness and Haemodynamics – A Validation Study. Clin Physiol Funct Imaging. 2003; 23(1): 31–6. http://dx.doi.org/10.1046/j.1475-097X.2003.00465.x10.1046/j.1475-097X.2003.00465.x12558611
- Casas O and Pallas-Areny R. Signal to Noise Ratio in Bioelectrical Impedance Measurements Using Synchronous Sampling. Ann IEEE Int Conf Eng Med Biol Soc. 1994: 890– 1. http://dx.doi.org/10.1109/iembs.1994.415198
- Gonzalez-Landaeta R, Casas O, and Pallas-Areny R. Heart Rate Detection From Plantar Bioimpedance Measurements. IEEE Trans Biomed Eng. 2008; 55(3): 1163–7. http://dx.doi.org/10.1109/TBME.2007.9065161833440910.1109/TBME.2007.906516
- Gomez-Clapers J, Casanella R, and Pallas-Areny R. Pulse Arrival Time Estimation From the Impedance Plethysmogram Obtained With a Handheld Device. Ann IEEE Int Conf Eng Med Biol Soc. 2011: 516–9. http://dx.doi.org/10.1109/iembs.2011.6090093
- Spinelli EM, Pallas-Areny R, and Mayosky MA. AC-coupled Front-end for Biopotential Measurements. IEEE Trans Biomed Eng. 2003; 50(3): 391–5. http://dx.doi.org/10.1109/TBME.2003.8088261266999610.1109/TBME.2003.808826
- Allen J and Murray A. Effects of Filtering on Multi-site Photoplethysmography Pulse Waveform Characteristics. Computers in Cardiology 2004: 485–88. http://dx.doi.org/10.1109/cic.2004.1442980
- Peura R. Blood Pressure and Sound. In: Webster JG editor: Medical Instrumentation Application and Design. New York: John Wiley & Sons; 2009: 293–337.
- Pan J and Tompkins WJ. A Real-time QRS Detection Algorithm. IEEE Trans Biomed Eng. 1985; 32(3): 230–6. http://dx.doi.org/10.1109/TBME.1985.3255323997178
- Millasseau SC, Stewart AD, Patel SJ, Redwood SR, and Chowienczyk PJ. Evaluation of Carotid-femoral Pulse Wave Velocity: Influence of Timing Algorithm and Heart Rate. J Hypertens. 2005; 45(2): 222–6. http://dx.doi.org/10.1161/01.HYP.0000154229.97341.d210.1161/01.HYP.0000154229.97341.d2