Abstract

Infections of vascular grafts are the most severe complications in vascular surgery. We present the case of a 73-year-old male with infection of a dacron prosthesis with a strain of Enterococcus faecalis. The patient was treated with replacement of a full prosthesis with a combined graft constructed from Biosynthetic Vascular graft Omniflow and autologous veins. This graft is recommended for implantation in patients with a higher risk of infection. Our case is one of the first reported usage of this kind of graft in the aortic region and in a 2 years observation period no recurrence of infection was observed.