Comparing goniometric and radiographic measurement of Q angle of the knee Cover

Comparing goniometric and radiographic measurement of Q angle of the knee

Open Access
|Jan 2017

Figures & Tables

Figure 1

Procedure for marking the bony prominence for the measurement of the Q angle (photograph with permission)
Procedure for marking the bony prominence for the measurement of the Q angle (photograph with permission)

Figure 2

Procedure for the measurement of Q angle with the goniometer (photograph with permission).
Procedure for the measurement of Q angle with the goniometer (photograph with permission).

Figure 3

Procedure for x-ray imaging of the lower limb (photograph with permission)
Procedure for x-ray imaging of the lower limb (photograph with permission)

Figure 4

Procedure for measurement of the Q angle on an x-ray film by intersecting the line between the bony prominence
Procedure for measurement of the Q angle on an x-ray film by intersecting the line between the bony prominence

Figure 5

Correlation between goniometric and radiographic measurement of the Q angle
Correlation between goniometric and radiographic measurement of the Q angle
DOI: https://doi.org/10.5372/1905-7415.0905.433 | Journal eISSN: 1875-855X | Journal ISSN: 1905-7415
Language: English
Page range: 631 - 636
Published on: Jan 31, 2017
Published by: Chulalongkorn University
In partnership with: Paradigm Publishing Services
Publication frequency: 6 issues per year

© 2017 Mohamed Faisal Chevidikunnan, Amer Al Saif, Harish Pai K, Lawrence Mathias, published by Chulalongkorn University