Functional tremor is a common movement disorder associated with prolonged disability and limited treatment options [1, 2, 3, 4]. It is distinguished from other movement disorders by such key diagnostic features as suppressibility and entrainment, whereby a patient’s attempts to match an externally cued frequency cause the tremor to abate or adopt this external frequency [5].

The feature of entrainment was adopted as a treatment strategy for 10 adult patients with functional tremor [6]. These patients underwent surface electromyography measurement of baseline tremor frequency. Patients were “cued” by tactile stimulation to adopt an oscillation 2/3 of the native tremor frequency, followed by 1/3 that frequency, while making flexion-extension movements at the wrist to match this externally cued frequency. Patients received continuous visual feedback on their performance and coaching as needed. If tremor was not dramatically improved after a single 2-hour session, patients returned for one or two further 2-hour sessions based on response. All patients improved following the entrainment sessions, with 60% of patients achieving long-term remission.

While this resource-intensive therapy is not available to most patients, the standard presence of accelerometers within modern smartphones makes this intervention readily adaptable for portable delivery. Therefore, we developed the Tremor Retrainer smartphone application for the treatment of patients with functional tremor, using patient experience and feedback to guide application development.

Methods

The Tremor Retrainer application was developed through a collaboration between the authors, with concept conceived by movement disorders neurologist JG and software code written by GB, an experienced software engineer. The application is cross platform, running on iOS and Android using the Xamarin platform, and was written in C#. Development of the core tremor detection algorithm relied on device accelerometer parameters extracted in 3 axes (x, y, z) and analyzed via Fast Fourier Transformation to determine dominant baseline tremor frequency. Treatment frequency was defined as 2/3 of baseline tremor frequency for the first half of a session, then 1/3 of baseline tremor frequency for the second half of a session. A visual gauge was added with needle position determined by frequencies of user’s voluntary movements relative to goal treatment frequency. Auditory cues were added as a “ticking” sound matching treatment frequency. Video 1 demonstrates the use of the application by a healthy volunteer.

Video 1

Application Demonstration. Demonstration of user beginning a treatment session with the Tremor Retrainer application, including initial measurement of baseline oscillatory movement and biofeedback to reflect the user’s accuracy in reaching goal frequency of voluntary movement. After stopping a session, the user can view a log of duration completed.

For the seven-day treatment program, the Tremor Retrainer smartphone application allows users to select the treatment day (Day 1 = 60-minute session, Days 2–7 = 30-minute sessions) from the home page. An instruction page prompts the user to extend arms with the smartphone strapped to the wrist and then “match the beat” by moving the hand up and down at the wrist. After a session is initiated, the application computes the average baseline tremor frequency from the first 10 seconds of a session. Following this baseline measurement period, the application provides auditory cues at 2/3 of the baseline tremor frequency for half a session, then 1/3 of the baseline tremor frequency for the second half of the session, while continuously measuring the frequency of the patient’s adopted (voluntary) flexion-extension wrist movements as they attempt to “match” the cued frequency. Measured frequency of voluntary movements is represented on a visual gauge, with goal range in the middle (Figure 1). A countdown timer displays the remaining duration of a session. Once a session is completed or ended by the user, the user can view a time-stamped log of duration completed.

tohm-13-1-823-g1.png
Figure 1

Visual Gauge. Users receive continuous biofeedback via a visual gauge throughout a treatment session. The needle moves in response to the frequency of the user’s voluntary movement: a patient matching the goal frequency will see a needle pointing to the center of the “goal range.”

The UVA Institutional Review Board (HSR220215) approved the recruitment of both pediatric and adult functional tremor patients for feedback on application development. Written informed consent and assent was obtained from all subjects and their guardians. Subjects received instruction from the primary investigator on application use and were observed completing a 60-minute session in the clinic. Subjects then were instructed to complete 30-minute sessions on days 2–7 at home. Subjects underwent structured interview after the initial session and after the entire protocol regarding usability of the application. Patients were asked about technical difficulties they encountered, any fatigue or soreness, whether they felt the application was easy to use, whether sessions were reasonable to complete at home, and whether they felt the application could be effective in treating their functional tremor. Separately, patients and their guardians were asked to report the impression of change in tremor severity using the patient-rated Clinical Global Impression-Improvement (CGI-I) scale.

Results

Three girls (age 17, 13, and 17) with functional tremor completed the one-week Tremor Retrainer protocol using Samsung, Motorola, and iPhone smartphones. No adult patients were referred for study participation during the study duration. All three subjects completed 100% of the initial 60-minute session. Subjects 1–3 completed 100%, 51%, and 83% of at-home sessions, respectively. Reasons for not initiating at-home sessions included inadequate time and psychological distress resulting in not wanting anything to touch the body. Reasons for early termination of sessions included application crashing and arm fatigue.

Observation of the initial session and feedback from patients prompted further software adjustments to address software bugs and improve the user experience. These included 1) creating minimum and maximum treatment frequencies to account for absence of detectable tremor when starting a session and to improve tolerability of sessions; 2) adjusting the code to ensure the visual gauge needle is centered in the goal range when patients are attempting to accurately match the new frequency; and 3) adjusting the countdown timer location to improve visibility.

During the structured interview, two subjects reported mild transient arm soreness and fatigue that resolved within minutes after a treatment session. All three subjects indicated that the application was easy to use, that the protocol was reasonable to do at home and could be effective in treating their functional tremor. The three subjects reported minimal improvement in tremor severity by CGI-I. Guardians also completed the CGI-I scale for 2 subjects: guardian of subject 2 noted marked improvement while guardian of subject 3 noted no change.

Discussion

We present the development of the Tremor Retrainer smartphone application for delivering biofeedback-based treatment to patients with functional tremor, with patient feedback contributing to improving key features. The application measures and modulates functional tremor frequency, with auditory cues and a visual gauge to guide the user. Patient feedback during the development prompted modifications in response to patient-specific factors.

In our small sample, three teenage patients with functional tremor were able to complete most sessions, including at home, with psychological distress the most common reason for inability to participate in sessions. This is an important preliminary indicator of feasibility as the prior entrainment study involved only adult patients with in-person coaching. This study involved for the first time pediatric patients in at-home sessions, broadening the potential applicability of tremor entrainment therapy.

This study was not designed to evaluate efficacy of the Tremor Retrainer application, but all three subjects noted at least minimal improvement in tremor severity on a patient-rated CGI-I scale. It is possible this change, or a part thereof, may be attributable to a placebo effect. Patients and guardians answered this question differently, which could reflect some difficulty in redirecting attention from symptoms and separating the tremor from other functional neurological symptoms [7, 8].

Our data are preliminary, and limited to three pediatric subjects. Ongoing software development is anticipated in response to needs of patients, clinical trial requirements, and software platforms. A future clinical trial will further evaluate feasibility and efficacy of the Tremor Retrainer application for the treatment of functional tremor.

Conclusion

The Tremor Retrainer smartphone application can provide an auditory frequency determined by a user’s baseline tremor frequency and visual feedback on accuracy. Matching this frequency with flexion-extension movements at the wrist may help attenuate or eliminate the functional tremor by “hijacking” the abnormal native tremor frequency. Future studies regarding feasibility and efficacy of this biofeedback-based treatment of functional tremor are planned.

Data Accessibility Statements

The Tremor Retrainer smartphone application and software code are available for review on request from the corresponding author (JG); the application code is not publicly available given its use in an ongoing clinical trial.

Acknowledgements

The authors thank Scott Resnick for his contributions to development of core tremor detection algorithm.

Funding Information

This project was funded by the University of Virginia Department of Neurology. JG and GB authors report no commercial associations relevant to this work. The University of Virginia Patent Foundation filed a provisional patent application on November 16, 2023.

Dr. Espay has received grant support from the NIH and the Michael J Fox Foundation; personal compensation as a consultant/scientific advisory board member for Neuroderm, Amneal, Acadia, Avion Pharmaceuticals, Acorda, Kyowa Kirin, Supernus (formerly, USWorldMeds), and Herantis Pharma; personal honoraria for speakership for Avion, Amneal, and Supernus; and publishing royalties from Lippincott Williams & Wilkins, Cambridge University Press, and Springer. He cofounded REGAIN Therapeutics and is co-inventor of the patent “Compositions and methods for treatment and/or prophylaxis of proteinopathies.”

Competing Interests

The authors have no competing interests to declare.

DOI: https://doi.org/10.5334/tohm.823 | Journal eISSN: 2160-8288
Language: English
Submitted on: Oct 10, 2023
Accepted on: Nov 29, 2023
Published on: Dec 19, 2023
Published by: Ubiquity Press
In partnership with: Paradigm Publishing Services
Publication frequency: 1 issue per year

© 2023 Jordan F. Garris, Gavin Bauman, Alberto J. Espay, published by Ubiquity Press
This work is licensed under the Creative Commons Attribution 4.0 License.