Electroencephalography in Orthostatic Tremor: A Prospective Study of 30 Patients Cover

Electroencephalography in Orthostatic Tremor: A Prospective Study of 30 Patients

Open Access
|May 2021

Figures & Tables

tohm-11-1-596-g1.png
Figure 1

EEG artifact. EEG recording showing tremor artifact in midline and posterior leads.

tohm-11-1-596-g2.png
Figure 2

EKG artifact. EEG recording showing tremor artifact in EKG lead.

Table 1

EEG Results.

SUBJECTEEG RESULTSARTIFACTTREMOR FREQUENCY ON EMG
1Normal15 Hz in posterior electrodes on EEG15 Hz
2Normal15 Hz in occipital electrodes on EEGNo EMG
3Normal17.6 Hz in EKGNo EMG
4Normal17 Hz in inferior orbital electrode on EEG, also seen in frontal, occipital and temporal electrodesNo EMG
5Generalized fast activity of low voltage which could be consistent with generalized medication’s effect15.6 Hz in infraorbital electrode on EEG15.6 Hz
6NormalPresent in bilateral temporal regions on EEG but not able to be measured15.5 Hz
7NormalPresent in temporal regions on EEG but frequency did not match (exact frequency not reported)18 Hz
8NormalNone notedCould not be measured
9Normal16.5 Hz in T3 and T5 electrodes on EEG and EKGNo EMG
10NormalPresent in occipital regions on EEG17 Hz
11Normal15 Hz in Oz electrode on EEGNo EMG
12Normal13.2 Hz in Oz electrode on EEG13.2 Hz
13Normal15 Hz in T5 and T3 electrodes on EEG while sitting and other midline and central electrodes when standingNo EMG
14Left anterior mid-temporal slow activityCould not be measuredNo EMG
15Right anterior mid-temporal slow activity18 Hz in occipital electrodes on EEGNo EMG
16Normal14 Hz in occipital electrodes on EEGNo EMG
17NormalPresent in occipital electrodes but not able to be measured15.5 Hz
18NormalCould not be measuredCould not be measured
19Normal16 Hz in Oz electrode on EEGNo EMG
20NormalNone15.5 Hz
21Normal14.5 Hz in posterior electrodes on EEG14.5 Hz
22Normal16.5 Hz in Oz and O2 electrodes on EEG16.5 Hz
23Normal14 Hz in infraorbital electrode on EEGNo EMG
24Normal18.5 Hz in EKGNo EMG
25Normal15.5–16 Hz in Oz, O1, O2, T5, and T6 electrodes on EEGNo EMG
26NormalPresent in bilateral temporal, midline, and posterior head leads on EEG but could not be measuredCould not be measured
27Normal15.5 Hz in occipital electrodes on EEGCould not be measured
28Normal16 Hz in O1, O2, Oz, and T4 electrodes on EEG16 Hz
29Right anterior mid-temporal slow activity7.3 Hz in O1 and Oz electrodes on EEG7.3 Hz
30NormalPresent in EEG but could not be measured15.5 Hz
DOI: https://doi.org/10.5334/tohm.596 | Journal eISSN: 2160-8288
Language: English
Submitted on: Dec 20, 2020
Accepted on: May 3, 2021
Published on: May 21, 2021
Published by: Ubiquity Press
In partnership with: Paradigm Publishing Services
Publication frequency: 1 issue per year

© 2021 Amy Hellman, John M. Bertoni, Danish E. Bhatti, Najib Murr, Diego Torres-Russotto, published by Ubiquity Press
This work is licensed under the Creative Commons Attribution 4.0 License.