Have a personal or library account? Click to login
Comparison of lower limb kinematics and kinetics estimation of basketball players during jumping with markerless and marker-based motion capture systems Cover

Comparison of lower limb kinematics and kinetics estimation of basketball players during jumping with markerless and marker-based motion capture systems

Open Access
|Aug 2025

References

  1. Andriacchi T., Strickland A., Gait analysis as a tool to assess joint kinetics. Biomechanics of normal and pathological human articulating joints, Springer, 1985, 83–102.
  2. Barzyk P., Zimmermann P., Stein M., Keim D., Gruber M., AI‐smartphone markerless motion capturing of hip, knee, and ankle joint kinematics during countermovement jumps, European Journal of Sport Science, 2024, 24 (10), 1452–1462.
  3. Bell A.L., Brand R.A., Pedersen D.R., Prediction of hip joint center location from external landmarks, Journal of Biomechanics, 1987, 20 (9), 913.
  4. Cabarkapa D., Cabarkapa D.V., Aleksic J., Philipp N.M., Scott A.A., Johnson Q.R., Fry A.C., Differences in countermovement vertical jump force-time metrics between starting and non-starting professional male basketball players, Front Sports Act Living, 2023, 5, 1327379.
  5. Camomilla V., Cereatti A., Cutti A.G., Fantozzi S., Stagni R., Vannozzi G., Methodological factors affecting joint moments estimation in clinical gait analysis: a systematic review, Biomed. Eng. Online, 2017, 16 (1), 106.
  6. Cao Z., Simon T., Wei S.-E., Sheikh Y. (eds.), Realtime multi-person 2d pose estimation using part affinity fields, Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, 2017.
  7. Della Croce U., Leardini A., Chiari L., Cappozzo A., Human movement analysis using stereophotogrammetry. Part 4: Assessment of anatomical landmark misplacement and its effects on joint kinematics, Gait Posture, 2005, 21 (2), 226–237.
  8. Derrick T.R., van den Bogert A.J., Cereatti A., Dumas R., Fantozzi S., Leardini A., ISB recommendations on the reporting of intersegmental forces and moments during human motion analysis, J. Biomech., 2020, 99, 109533.
  9. Dugan S.A., Bhat K.P., Biomechanics and analysis of running gait, Phys. Med. Rehabil. Clin. N. Am., 2005, 16 (3), 603–621.
  10. Grood E.S., Suntay W.J., A joint coordinate system for the clinical description of three-dimensional motions: application to the knee, J. Biomech. Eng., 1983, 105 (2), 136–144.
  11. Horsak B., Eichmann A., Lauer K., Prock K., Krondorfer P., Siragy T., Dumphart B., Concurrent validity of smartphonebased markerless motion capturing to quantify lower-limb joint kinematics in healthy and pathological gait, J. Biomech., 2023, 159, 111801.
  12. Huang T., Ruan M., Huang S., Fan L., Wu X., Comparison of kinematics and joint moments calculations for lower limbs during gait using markerless and marker-based motion capture, Frontiers in Bioengineering and Biotechnology, 2024, 12, 1280363.
  13. Ito N., Sigurðsson H.B., Seymore K.D., Arhos E.K., Buchanan T.S., Snyder-Mackler L., Silbernagel K.G., Markerless motion capture: What clinician-scientists need to know right now, JSAMS Plus, 2022, 1.
  14. Kanko R.M., Laende E.K., Davis E.M., Selbie W.S., Deluzio K.J., Concurrent assessment of gait kinematics using marker-based and markerless motion capture, J. Biomech., 2021, 127, 110665.
  15. Kanko R.M., Outerleys J.B., Laende E.K., Selbie W.S., Deluzio K.J., Comparison of Concurrent and Asynchronous Running Kinematics and Kinetics From Marker-Based and Markerless Motion Capture Under Varying Clothing Conditions, J. Appl. Biomech., 2024, 40 (2), 129–137.
  16. Leardini A., Chiari L., Della Croce U., Cappozzo A., Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation, Gait Posture, 2005, 21 (2), 212–225.
  17. Leidersdorf E., Rauch J., Reeves T., Borkan L., Francis J., Storey L. et al., Reliability and Effectiveness of a Lateral Countermovement Jump for Stratifying Shuffling Performance Amongst Elite Basketball Players, Sports (Basel), 2022, 10 (11).
  18. Li G., Wuerz T.H., DeFrate L.E., Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics, J. Biomech. Eng., 2004, 126 (2), 314–318.
  19. Mathis A., Mamidanna P., Cury K.M., Abe T., Murthy V.N., Mathis M.W., Bethge M., DeepLabCut: markerless pose estimation of user-defined body parts with deep learning, Nat. Neurosci., 2018, 21 (9), 1281–1289.
  20. Mercadal-Baudart C., Liu C.J., Farrell G., Boyne M., González Escribano J., Smolic A., Simms C., Exercise quantification from single camera view markerless 3D pose estimation, Heliyon, 2024, 10 (6), e27596.
  21. Moisio K.C., Sumner D.R., Shott S., Hurwitz D.E., Normalization of joint moments during gait: a comparison of two techniques, J. Biomech., 2003, 36 (4), 599–603.
  22. Needham L., Evans M., Wade L., Cosker D.P., McGuigan M.P., Bilzon J.L., Colyer S.L., The development and evaluation of a fully automated markerless motion capture workflow, J. Biomech., 2022, 144, 111338.
  23. Riley P.O., Dicharry J., Franz J., Della Croce U., Wilder R.P., Kerrigan D.C., A kinematics and kinetic comparison of overground and treadmill running, Med. Sci. Sports Exerc., 2008, 40 (6), 1093–1100.
  24. Robertson D., Caldwell G., Hamill J., Kamen G., Whittlesey S., Research methods in biomechanics, 2nd ed., Boston (USA), Human Kinetics, 2013.
  25. Robertson G., Research Methods in Biomechanics, Human Kinetics Publishers, 2013.
  26. Schober P., Boer C., Schwarte L.A., Correlation Coefficients: Appropriate Use and Interpretation, Anesth. Analg., 2018, 126 (5), 1763–1768.
  27. Song K., Hullfish T.J., Scattone Silva R., Silbernagel K.G., Baxter J.R., Markerless motion capture estimates of lower extremity kinematics and kinetics are comparable to marker-based across 8 movements, J. Biomech., 2023, 157, 111751.
  28. Stagni R., Leardini A., Cappozzo A., Grazia Benedetti M., Cappello A., Effects of hip joint centre mislocation on gait analysis results, J. Biomech., 2000, 33 (11), 1479–1487.
  29. Stojiljkovic N., Stankovic D., Pelemis V., Cokorilo N., Olanescu M., Peris M. et al., Validity and reliability of the My Jump 2 app for detecting interlimb asymmetry in young female basketball players, Front. Sports Act. Living, 2024, 6, 1362646.
  30. Tang H., Munkasy B., Li L., Differences between lower extremity joint running kinetics captured by marker-based and markerless systems were speed dependent, J. Sport Health Sci., 2024, 13 (4), 569–578.
  31. Tashman S., Anderst W., In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency, J. Biomech. Eng., 2003, 125 (2), 238–245.
  32. Van Hooren B., Pecasse N., Meijer K., Essers J.M.N., The accuracy of markerless motion capture combined with computer vision techniques for measuring running kinematics, Scand. J. Med. Sci. Sports, 2023, 33 (6), 966–978.
  33. Verheul J., Sueda S., Yeo S.H. (eds.), Muscle inertia during running: A massive change of moments?, 40th International Society of Biomechanics in Sports Conference, 2022.
  34. Woltring H.J., A Fortran package for generalized, cross-validatory spline smoothing and differentiation, Advances in Engineering Software (1978), 1986, 8 (2), 104–113.
  35. Wu G., Siegler S., Allard P., Kirtley C., Leardini A., Rosenbaum D. et al., ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion – Part I. Ankle, hip, and spine, International Society of Biomechanics. J. Biomech.. 2002, 35 (4), 543–548.
  36. Wu G., van der Helm F.C., Veeger H.E., Makhsous M., Van Roy P., Anglin C. et al., ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion – Part II. Shoulder, elbow, wrist and hand, J. Biomech., 2005, 38 (5), 981–992.
DOI: https://doi.org/10.37190/abb/207092 | Journal eISSN: 2450-6303 | Journal ISSN: 1509-409X
Language: English
Page range: 133 - 145
Submitted on: Apr 12, 2025
Accepted on: Jun 12, 2025
Published on: Aug 26, 2025
Published by: Wroclaw University of Science and Technology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2025 Linyu Wei, Changzhi Yang, Xi Huang, Lili Tu, Yanjia Xu, Ming Li, Zhe Hu, published by Wroclaw University of Science and Technology
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.